Numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facility

BackgroundDue to the complex structure of the ventilation ducts in nuclear facilities, the concentration distribution of radionuclides such as aerosols in the ducts is uneven. The inhomogeneity of aerosol distribution brings great challenges to the sampling representativeness of radiation monitoring...

Full description

Bibliographic Details
Main Authors: RAN Peng, GU Weiguo, NIE Baojie
Format: Article
Language:zho
Published: Science Press 2023-09-01
Series:He jishu
Subjects:
Online Access:http://www.hjs.sinap.ac.cn/thesisDetails#10.11889/j.0253-3219.2023.hjs.46.090504&lang=zh
_version_ 1797405214289952768
author RAN Peng
GU Weiguo
NIE Baojie
author_facet RAN Peng
GU Weiguo
NIE Baojie
author_sort RAN Peng
collection DOAJ
description BackgroundDue to the complex structure of the ventilation ducts in nuclear facilities, the concentration distribution of radionuclides such as aerosols in the ducts is uneven. The inhomogeneity of aerosol distribution brings great challenges to the sampling representativeness of radiation monitoring. In chemical processes, static stirring devices are commonly used to enhance the homogeneity of the product mix. However, this device has not been applied in the nuclear power field.PurposeAccordingly, this study aims to improve the mixing uniformity of aerosols in air supply pipelines by using static stirring devices, so as to provide a reference for the representativeness of radiation monitoring sampling.MethodsThe stirring effects of three different stirring devices were investigated through numerical simulations. The RNG k-ε model was used to simulate the gas phase flow field, and the discrete phase model (DPM) was employed in ANSYS CFX software to simulate the behavior of aerosol particles. Selection of the particle size of aerosols followed the recommendations in the sampling representative standards, with the specific size of 10 μm. The other boundary conditions in the simulation were based on the actual operating conditions of a nuclear power plant. As a result, the effects of different stirring devices on the flow field and aerosol concentration distribution were obtained.ResultsThe static stirring device can form strong swirls, thereby improving the uniformity of aerosol distribution. Increasing the twist angle of the blades and the proportion area of the inner blades strengthened the generated vortex field, further affecting the diffusion of aerosols. The static stirring device with an increased inner blade area exhibited a moderate swirl intensity, and better stirring effect than those of the other two structures. The coefficient of variation of the aerosol concentration decreased by 30.60%.ConclusionsInstalling a static stirring device in an air supply duct is a feasible method to improve the mixing uniformity of aerosols. Owing to the complex structure of ventilation ducts in nuclear facilities, the concentration distribution of radionuclides, such as aerosols, in the ducts is uneven. This inhomogeneous aerosol distribution poses significant challenges to the sampling representativeness of radiation monitoring. In chemical processes, static stirring devices are commonly used to enhance the homogeneity of the product mix. However, these devices have not yet been applied in the field of nuclear power.
first_indexed 2024-03-09T03:06:35Z
format Article
id doaj.art-fc04a96a88c449b4b05c4dc3fe031341
institution Directory Open Access Journal
issn 0253-3219
language zho
last_indexed 2024-03-09T03:06:35Z
publishDate 2023-09-01
publisher Science Press
record_format Article
series He jishu
spelling doaj.art-fc04a96a88c449b4b05c4dc3fe0313412023-12-04T07:35:01ZzhoScience PressHe jishu0253-32192023-09-0146909050409050410.11889/j.0253-3219.2023.hjs.46.0905040253-3219(2023)09-0077-08Numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facilityRAN PengGU WeiguoNIE BaojieBackgroundDue to the complex structure of the ventilation ducts in nuclear facilities, the concentration distribution of radionuclides such as aerosols in the ducts is uneven. The inhomogeneity of aerosol distribution brings great challenges to the sampling representativeness of radiation monitoring. In chemical processes, static stirring devices are commonly used to enhance the homogeneity of the product mix. However, this device has not been applied in the nuclear power field.PurposeAccordingly, this study aims to improve the mixing uniformity of aerosols in air supply pipelines by using static stirring devices, so as to provide a reference for the representativeness of radiation monitoring sampling.MethodsThe stirring effects of three different stirring devices were investigated through numerical simulations. The RNG k-ε model was used to simulate the gas phase flow field, and the discrete phase model (DPM) was employed in ANSYS CFX software to simulate the behavior of aerosol particles. Selection of the particle size of aerosols followed the recommendations in the sampling representative standards, with the specific size of 10 μm. The other boundary conditions in the simulation were based on the actual operating conditions of a nuclear power plant. As a result, the effects of different stirring devices on the flow field and aerosol concentration distribution were obtained.ResultsThe static stirring device can form strong swirls, thereby improving the uniformity of aerosol distribution. Increasing the twist angle of the blades and the proportion area of the inner blades strengthened the generated vortex field, further affecting the diffusion of aerosols. The static stirring device with an increased inner blade area exhibited a moderate swirl intensity, and better stirring effect than those of the other two structures. The coefficient of variation of the aerosol concentration decreased by 30.60%.ConclusionsInstalling a static stirring device in an air supply duct is a feasible method to improve the mixing uniformity of aerosols. Owing to the complex structure of ventilation ducts in nuclear facilities, the concentration distribution of radionuclides, such as aerosols, in the ducts is uneven. This inhomogeneous aerosol distribution poses significant challenges to the sampling representativeness of radiation monitoring. In chemical processes, static stirring devices are commonly used to enhance the homogeneity of the product mix. However, these devices have not yet been applied in the field of nuclear power.http://www.hjs.sinap.ac.cn/thesisDetails#10.11889/j.0253-3219.2023.hjs.46.090504&lang=zhair supply pipestatic stirring deviceaerosolnumerical simulationmixing uniformity
spellingShingle RAN Peng
GU Weiguo
NIE Baojie
Numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facility
He jishu
air supply pipe
static stirring device
aerosol
numerical simulation
mixing uniformity
title Numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facility
title_full Numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facility
title_fullStr Numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facility
title_full_unstemmed Numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facility
title_short Numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facility
title_sort numerical analysis of effect of static stirring device on mixing uniformity of aerosol in the air duct of a nuclear facility
topic air supply pipe
static stirring device
aerosol
numerical simulation
mixing uniformity
url http://www.hjs.sinap.ac.cn/thesisDetails#10.11889/j.0253-3219.2023.hjs.46.090504&lang=zh
work_keys_str_mv AT ranpeng numericalanalysisofeffectofstaticstirringdeviceonmixinguniformityofaerosolintheairductofanuclearfacility
AT guweiguo numericalanalysisofeffectofstaticstirringdeviceonmixinguniformityofaerosolintheairductofanuclearfacility
AT niebaojie numericalanalysisofeffectofstaticstirringdeviceonmixinguniformityofaerosolintheairductofanuclearfacility