Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in Radiotherapy

Introduction: Patient-specific quality assurance (PSQA) assumes a vital role in precise and accurate radiation delivery to cancer patients. Since the patient body comprises heterogeneous media, the present study aimed to fabricate a heterogeneous thoracic phantom for PSQA.Material and Methods: Heter...

Full description

Bibliographic Details
Main Authors: Vinod Gangwar, Avinash Agarwal, Om Prakash Gurjar, Lalit Kumar, Vineet Kumar Mishra, Surendra Mishra
Format: Article
Language:English
Published: Mashhad University of Medical Sciences 2022-03-01
Series:Iranian Journal of Medical Physics
Subjects:
Online Access:https://ijmp.mums.ac.ir/article_18359_cdbec76c88e20aa6a007039af7e9f2ad.pdf
_version_ 1797209662668406784
author Vinod Gangwar
Avinash Agarwal
Om Prakash Gurjar
Lalit Kumar
Vineet Kumar Mishra
Surendra Mishra
author_facet Vinod Gangwar
Avinash Agarwal
Om Prakash Gurjar
Lalit Kumar
Vineet Kumar Mishra
Surendra Mishra
author_sort Vinod Gangwar
collection DOAJ
description Introduction: Patient-specific quality assurance (PSQA) assumes a vital role in precise and accurate radiation delivery to cancer patients. Since the patient body comprises heterogeneous media, the present study aimed to fabricate a heterogeneous thoracic phantom for PSQA.Material and Methods: Heterogeneous thoracic (HT) phantom was fabricated using rib cage madeup of bone equivalent material, kailwood to mimic lungs and wax to mimic various body parts. Physical density of all these materials used in phantom fabrication was measured and compared with that of the corresponding part of actual human thorax. One beam was planned on the computed tomography (CT) images of phantom and actual patient thorax region. Dose distribution in both the plans was measured and analyzed.Results:The estimated densities of heart, lung, ribs, scapula, spine, and chest wall tissues were 0.804±0.007, 0.186±0.010, 1.796±0.061, 2.017±0.026, 2.106±0.029 and 0.739±0.028 respectively in case of HT phantom while 1.038±0.010, 0.199±0.031, 1.715±0.040, 2.006±0.019, 1.929±0.065 and 0.816±0.028 g/cc, respectively in case of actual human thorax region.The depths of isodose curves in HT phantom were also comparable to the isodose curve’s depths inreal patient. PSQA results were within ±3% for flat beam (FB) and flattening filtered free beam (FFFB) of 6 megavolts (MV) energy.Conclusion: Density and dose distribution pattern in HT phantom were similar to that in actual human thorax region. Thus, fabricated HT phantom can be utilized for radiation dosimetry in thoracic cancer patients. The materials used to develop HT phantom are easily available in market at an affordable price and easy to craft.
first_indexed 2024-04-13T08:43:56Z
format Article
id doaj.art-fc267150bf9e4195a4ae48d94cfac5f1
institution Directory Open Access Journal
issn 2345-3672
language English
last_indexed 2024-04-24T09:58:16Z
publishDate 2022-03-01
publisher Mashhad University of Medical Sciences
record_format Article
series Iranian Journal of Medical Physics
spelling doaj.art-fc267150bf9e4195a4ae48d94cfac5f12024-04-14T06:28:29ZengMashhad University of Medical SciencesIranian Journal of Medical Physics2345-36722022-03-01192859010.22038/ijmp.2021.52426.186218359Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in RadiotherapyVinod Gangwar0Avinash Agarwal1Om Prakash Gurjar2Lalit Kumar3Vineet Kumar Mishra4Surendra Mishra5Department of Physics Bareilly College Bareilly, Uttar Pradesh Medical Physics Division & Radiation Oncology Department, Apollo Medics Hospital, LucknowDepartment of Physics Bareilly College Bareilly, Uttar PradeshGovernment Cancer Hospital, Mahatma Gandhi Memorial Medical College, IndoreDepartment of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New DelhiMedical Physics Division & Radiation Oncology Department, Apollo Medics Hospital, LucknowDepartment of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical sciences, Lucknow, IndiaIntroduction: Patient-specific quality assurance (PSQA) assumes a vital role in precise and accurate radiation delivery to cancer patients. Since the patient body comprises heterogeneous media, the present study aimed to fabricate a heterogeneous thoracic phantom for PSQA.Material and Methods: Heterogeneous thoracic (HT) phantom was fabricated using rib cage madeup of bone equivalent material, kailwood to mimic lungs and wax to mimic various body parts. Physical density of all these materials used in phantom fabrication was measured and compared with that of the corresponding part of actual human thorax. One beam was planned on the computed tomography (CT) images of phantom and actual patient thorax region. Dose distribution in both the plans was measured and analyzed.Results:The estimated densities of heart, lung, ribs, scapula, spine, and chest wall tissues were 0.804±0.007, 0.186±0.010, 1.796±0.061, 2.017±0.026, 2.106±0.029 and 0.739±0.028 respectively in case of HT phantom while 1.038±0.010, 0.199±0.031, 1.715±0.040, 2.006±0.019, 1.929±0.065 and 0.816±0.028 g/cc, respectively in case of actual human thorax region.The depths of isodose curves in HT phantom were also comparable to the isodose curve’s depths inreal patient. PSQA results were within ±3% for flat beam (FB) and flattening filtered free beam (FFFB) of 6 megavolts (MV) energy.Conclusion: Density and dose distribution pattern in HT phantom were similar to that in actual human thorax region. Thus, fabricated HT phantom can be utilized for radiation dosimetry in thoracic cancer patients. The materials used to develop HT phantom are easily available in market at an affordable price and easy to craft.https://ijmp.mums.ac.ir/article_18359_cdbec76c88e20aa6a007039af7e9f2ad.pdfalgorithmheterogeneous phantomquality assurance
spellingShingle Vinod Gangwar
Avinash Agarwal
Om Prakash Gurjar
Lalit Kumar
Vineet Kumar Mishra
Surendra Mishra
Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in Radiotherapy
Iranian Journal of Medical Physics
algorithm
heterogeneous phantom
quality assurance
title Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in Radiotherapy
title_full Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in Radiotherapy
title_fullStr Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in Radiotherapy
title_full_unstemmed Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in Radiotherapy
title_short Suitability Assessment of an Indigenous Heterogeneous Thoracic Phantom for Patient-Specific Quality Assurance in Radiotherapy
title_sort suitability assessment of an indigenous heterogeneous thoracic phantom for patient specific quality assurance in radiotherapy
topic algorithm
heterogeneous phantom
quality assurance
url https://ijmp.mums.ac.ir/article_18359_cdbec76c88e20aa6a007039af7e9f2ad.pdf
work_keys_str_mv AT vinodgangwar suitabilityassessmentofanindigenousheterogeneousthoracicphantomforpatientspecificqualityassuranceinradiotherapy
AT avinashagarwal suitabilityassessmentofanindigenousheterogeneousthoracicphantomforpatientspecificqualityassuranceinradiotherapy
AT omprakashgurjar suitabilityassessmentofanindigenousheterogeneousthoracicphantomforpatientspecificqualityassuranceinradiotherapy
AT lalitkumar suitabilityassessmentofanindigenousheterogeneousthoracicphantomforpatientspecificqualityassuranceinradiotherapy
AT vineetkumarmishra suitabilityassessmentofanindigenousheterogeneousthoracicphantomforpatientspecificqualityassuranceinradiotherapy
AT surendramishra suitabilityassessmentofanindigenousheterogeneousthoracicphantomforpatientspecificqualityassuranceinradiotherapy