TITRATION METHOD OF AB0 ANTIBODIES WITH THE USE OF MODERN GEL TECHNOLOGY IN AB0-INCOMPATIBLE TRANSPLANTATION

It is shown that developed method of titrating AB0 antibodies allows defi ning the titer of the investigational antibodies more precisely on 1–3 dilution of serum compared to the prototype method (titration method of antibodiesin saline medium on the plane). It is more obvious as it excludes hardly...

Full description

Bibliographic Details
Main Authors: A. K. Porunova, V. V. Morozova, I. E. Tsiroulnikova, O. M. Tsiroulnikova, S. V. Gautier
Format: Article
Language:Russian
Published: Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov 2014-12-01
Series:Vestnik Transplantologii i Iskusstvennyh Organov
Subjects:
Online Access:https://journal.transpl.ru/vtio/article/view/470
_version_ 1797872043344003072
author A. K. Porunova
V. V. Morozova
I. E. Tsiroulnikova
O. M. Tsiroulnikova
S. V. Gautier
author_facet A. K. Porunova
V. V. Morozova
I. E. Tsiroulnikova
O. M. Tsiroulnikova
S. V. Gautier
author_sort A. K. Porunova
collection DOAJ
description It is shown that developed method of titrating AB0 antibodies allows defi ning the titer of the investigational antibodies more precisely on 1–3 dilution of serum compared to the prototype method (titration method of antibodiesin saline medium on the plane). It is more obvious as it excludes hardly interpretable results due to the possibility of conducting visual assessment of agglutination reaction in the gel card thick column and requires less time foranalysis. The results can be saved for comparison with the results of further research. That is not possible under prototype titration method. Aim: our aim is to create a laboratory technique that can accurately, reliably and clearly produce titration of AB0 system antibodies, including in patients with low initial concentration of agglutinins in the blood; a technique more economical in terms of spending serum and that takes less time.Materials and methods: those modes were empirically chosen which allow titration of AB0 system agglutinins using gel technology based micro typing; to titer group antibodies 1640 serum assays of recipients in AB0-incompatibletransplantation were analyzed.The result of the use of specially developed method in organ transplantation from incompatible blood donors consists in enhancing accuracy, sensitivity of natural, complete and incomplete AB0 system immune antibodies titration, in its clarity, using of blood micro-doses for earlier detection of sensitizing of the patient, which is especially important in Pediatrics. Conclusion: the developed procedure of AB0-antibodies’ titration using modern gel technology makes possible a more precise monitoring of the titer of antibodies that is necessary to predict the graft rejection risk, to select the Protocol of preoperative preparation and postoperative management of patients, to assess the effectiveness of therapy in patients for whom it is diffi cult to fi nd a compatible blood type donor, and for whom today AB0-incompatible transplantation is a life-saving.
first_indexed 2024-04-10T00:53:37Z
format Article
id doaj.art-fc5839ea120144fa97c8b4a76c4f83f0
institution Directory Open Access Journal
issn 1995-1191
language Russian
last_indexed 2024-04-10T00:53:37Z
publishDate 2014-12-01
publisher Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
record_format Article
series Vestnik Transplantologii i Iskusstvennyh Organov
spelling doaj.art-fc5839ea120144fa97c8b4a76c4f83f02023-03-13T10:37:22ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.ShumakovVestnik Transplantologii i Iskusstvennyh Organov1995-11912014-12-01164404410.15825/1995-1191-2014-4-40-44408TITRATION METHOD OF AB0 ANTIBODIES WITH THE USE OF MODERN GEL TECHNOLOGY IN AB0-INCOMPATIBLE TRANSPLANTATIONA. K. Porunova0V. V. Morozova1I. E. Tsiroulnikova2O. M. Tsiroulnikova3S. V. Gautier4V.I. Shumakov Federal Research Center of Transplantology and Artifi cial Organs of the Ministry of Healthcare of the Russian Federation, Moscow, Russian FederationV.I. Shumakov Federal Research Center of Transplantology and Artifi cial Organs of the Ministry of Healthcare of the Russian Federation, Moscow, Russian FederationV.I. Shumakov Federal Research Center of Transplantology and Artifi cial Organs of the Ministry of Healthcare of the Russian Federation, Moscow, Russian FederationV.I. Shumakov Federal Research Center of Transplantology and Artifi cial Organs of the Ministry of Healthcare of the Russian Federation, Moscow, Russian FederationV.I. Shumakov Federal Research Center of Transplantology and Artifi cial Organs of the Ministry of Healthcare of the Russian Federation, Moscow, Russian FederationIt is shown that developed method of titrating AB0 antibodies allows defi ning the titer of the investigational antibodies more precisely on 1–3 dilution of serum compared to the prototype method (titration method of antibodiesin saline medium on the plane). It is more obvious as it excludes hardly interpretable results due to the possibility of conducting visual assessment of agglutination reaction in the gel card thick column and requires less time foranalysis. The results can be saved for comparison with the results of further research. That is not possible under prototype titration method. Aim: our aim is to create a laboratory technique that can accurately, reliably and clearly produce titration of AB0 system antibodies, including in patients with low initial concentration of agglutinins in the blood; a technique more economical in terms of spending serum and that takes less time.Materials and methods: those modes were empirically chosen which allow titration of AB0 system agglutinins using gel technology based micro typing; to titer group antibodies 1640 serum assays of recipients in AB0-incompatibletransplantation were analyzed.The result of the use of specially developed method in organ transplantation from incompatible blood donors consists in enhancing accuracy, sensitivity of natural, complete and incomplete AB0 system immune antibodies titration, in its clarity, using of blood micro-doses for earlier detection of sensitizing of the patient, which is especially important in Pediatrics. Conclusion: the developed procedure of AB0-antibodies’ titration using modern gel technology makes possible a more precise monitoring of the titer of antibodies that is necessary to predict the graft rejection risk, to select the Protocol of preoperative preparation and postoperative management of patients, to assess the effectiveness of therapy in patients for whom it is diffi cult to fi nd a compatible blood type donor, and for whom today AB0-incompatible transplantation is a life-saving.https://journal.transpl.ru/vtio/article/view/470ab0-incompatible transplantationtitration of ab0-antibodiesgel technology
spellingShingle A. K. Porunova
V. V. Morozova
I. E. Tsiroulnikova
O. M. Tsiroulnikova
S. V. Gautier
TITRATION METHOD OF AB0 ANTIBODIES WITH THE USE OF MODERN GEL TECHNOLOGY IN AB0-INCOMPATIBLE TRANSPLANTATION
Vestnik Transplantologii i Iskusstvennyh Organov
ab0-incompatible transplantation
titration of ab0-antibodies
gel technology
title TITRATION METHOD OF AB0 ANTIBODIES WITH THE USE OF MODERN GEL TECHNOLOGY IN AB0-INCOMPATIBLE TRANSPLANTATION
title_full TITRATION METHOD OF AB0 ANTIBODIES WITH THE USE OF MODERN GEL TECHNOLOGY IN AB0-INCOMPATIBLE TRANSPLANTATION
title_fullStr TITRATION METHOD OF AB0 ANTIBODIES WITH THE USE OF MODERN GEL TECHNOLOGY IN AB0-INCOMPATIBLE TRANSPLANTATION
title_full_unstemmed TITRATION METHOD OF AB0 ANTIBODIES WITH THE USE OF MODERN GEL TECHNOLOGY IN AB0-INCOMPATIBLE TRANSPLANTATION
title_short TITRATION METHOD OF AB0 ANTIBODIES WITH THE USE OF MODERN GEL TECHNOLOGY IN AB0-INCOMPATIBLE TRANSPLANTATION
title_sort titration method of ab0 antibodies with the use of modern gel technology in ab0 incompatible transplantation
topic ab0-incompatible transplantation
titration of ab0-antibodies
gel technology
url https://journal.transpl.ru/vtio/article/view/470
work_keys_str_mv AT akporunova titrationmethodofab0antibodieswiththeuseofmoderngeltechnologyinab0incompatibletransplantation
AT vvmorozova titrationmethodofab0antibodieswiththeuseofmoderngeltechnologyinab0incompatibletransplantation
AT ietsiroulnikova titrationmethodofab0antibodieswiththeuseofmoderngeltechnologyinab0incompatibletransplantation
AT omtsiroulnikova titrationmethodofab0antibodieswiththeuseofmoderngeltechnologyinab0incompatibletransplantation
AT svgautier titrationmethodofab0antibodieswiththeuseofmoderngeltechnologyinab0incompatibletransplantation