Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins

Phycotoxins and mycotoxins, such as paralytic shellfish poisoning toxins, type A trichothecenes, and aflatoxins are among the most toxic low molecular weight toxins associated with human poisoning incidents through the consumption of naturally contaminated food. Therefore, there is an utmost need fo...

Full description

Bibliographic Details
Main Authors: Katharina Schulz, Christopher Pöhlmann, Richard Dietrich, Erwin Märtlbauer, Thomas Elßner
Format: Article
Language:English
Published: Frontiers Media S.A. 2019-02-01
Series:Frontiers in Chemistry
Subjects:
Online Access:https://www.frontiersin.org/article/10.3389/fchem.2019.00031/full
_version_ 1818214447908388864
author Katharina Schulz
Katharina Schulz
Christopher Pöhlmann
Richard Dietrich
Erwin Märtlbauer
Thomas Elßner
author_facet Katharina Schulz
Katharina Schulz
Christopher Pöhlmann
Richard Dietrich
Erwin Märtlbauer
Thomas Elßner
author_sort Katharina Schulz
collection DOAJ
description Phycotoxins and mycotoxins, such as paralytic shellfish poisoning toxins, type A trichothecenes, and aflatoxins are among the most toxic low molecular weight toxins associated with human poisoning incidents through the consumption of naturally contaminated food. Therefore, there is an utmost need for rapid and sensitive on-site detection systems. Herein, an electrochemical biochip for fast detection of saxitoxin, T-2 toxin as well as aflatoxin M1 and their corresponding congeners, respectively, using a portable and fully automated detection platform (pBDi, portable BioDetector integrated) was developed. Toxin analysis is facilitated upon the biochip via an indirect competitive immunoassay using toxin-specific antibodies combined with anti-idiotypic antibodies. The developed biochips enable detection in the low ng/mL-range within 17 min. Moreover, the assays cover a wide linear working range of 2–3 orders of magnitude above the limit of detection with an inter-chip coefficient of variation lower than 15%. The broad specificity of the employed antibodies which react with a large number of congeners within the respective toxin group allows efficient screening of contaminated samples for the presence of these low molecular weight toxins. With respect to the analysis of human urine samples, we focused here on the detection of saxitoxin, HT-2 toxin, and aflatoxin M1, all known as biomarkers of acute toxin exposure. Overall, it was proved that the developed biochip assays can be used to rapidly and reliably identify severe intoxications caused by these low molecular weight toxins.
first_indexed 2024-12-12T06:20:20Z
format Article
id doaj.art-fc97849ea9014e318d3b53dc7642f3f4
institution Directory Open Access Journal
issn 2296-2646
language English
last_indexed 2024-12-12T06:20:20Z
publishDate 2019-02-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Chemistry
spelling doaj.art-fc97849ea9014e318d3b53dc7642f3f42022-12-22T00:34:55ZengFrontiers Media S.A.Frontiers in Chemistry2296-26462019-02-01710.3389/fchem.2019.00031435734Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight ToxinsKatharina Schulz0Katharina Schulz1Christopher Pöhlmann2Richard Dietrich3Erwin Märtlbauer4Thomas Elßner5Bruker Daltonik GmbH, Leipzig, GermanyDepartment of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Munich, GermanyBruker Daltonik GmbH, Leipzig, GermanyDepartment of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Munich, GermanyDepartment of Veterinary Sciences, Faculty of Veterinary Medicine, Ludwig-Maximilians-Universität München, Munich, GermanyBruker Daltonik GmbH, Leipzig, GermanyPhycotoxins and mycotoxins, such as paralytic shellfish poisoning toxins, type A trichothecenes, and aflatoxins are among the most toxic low molecular weight toxins associated with human poisoning incidents through the consumption of naturally contaminated food. Therefore, there is an utmost need for rapid and sensitive on-site detection systems. Herein, an electrochemical biochip for fast detection of saxitoxin, T-2 toxin as well as aflatoxin M1 and their corresponding congeners, respectively, using a portable and fully automated detection platform (pBDi, portable BioDetector integrated) was developed. Toxin analysis is facilitated upon the biochip via an indirect competitive immunoassay using toxin-specific antibodies combined with anti-idiotypic antibodies. The developed biochips enable detection in the low ng/mL-range within 17 min. Moreover, the assays cover a wide linear working range of 2–3 orders of magnitude above the limit of detection with an inter-chip coefficient of variation lower than 15%. The broad specificity of the employed antibodies which react with a large number of congeners within the respective toxin group allows efficient screening of contaminated samples for the presence of these low molecular weight toxins. With respect to the analysis of human urine samples, we focused here on the detection of saxitoxin, HT-2 toxin, and aflatoxin M1, all known as biomarkers of acute toxin exposure. Overall, it was proved that the developed biochip assays can be used to rapidly and reliably identify severe intoxications caused by these low molecular weight toxins.https://www.frontiersin.org/article/10.3389/fchem.2019.00031/fullelectrochemical biochipon-site detectionpBDicompetitive immunoassayanti-idiotypic antibodiesaflatoxins
spellingShingle Katharina Schulz
Katharina Schulz
Christopher Pöhlmann
Richard Dietrich
Erwin Märtlbauer
Thomas Elßner
Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins
Frontiers in Chemistry
electrochemical biochip
on-site detection
pBDi
competitive immunoassay
anti-idiotypic antibodies
aflatoxins
title Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins
title_full Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins
title_fullStr Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins
title_full_unstemmed Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins
title_short Electrochemical Biochip Assays Based on Anti-idiotypic Antibodies for Rapid and Automated On-Site Detection of Low Molecular Weight Toxins
title_sort electrochemical biochip assays based on anti idiotypic antibodies for rapid and automated on site detection of low molecular weight toxins
topic electrochemical biochip
on-site detection
pBDi
competitive immunoassay
anti-idiotypic antibodies
aflatoxins
url https://www.frontiersin.org/article/10.3389/fchem.2019.00031/full
work_keys_str_mv AT katharinaschulz electrochemicalbiochipassaysbasedonantiidiotypicantibodiesforrapidandautomatedonsitedetectionoflowmolecularweighttoxins
AT katharinaschulz electrochemicalbiochipassaysbasedonantiidiotypicantibodiesforrapidandautomatedonsitedetectionoflowmolecularweighttoxins
AT christopherpohlmann electrochemicalbiochipassaysbasedonantiidiotypicantibodiesforrapidandautomatedonsitedetectionoflowmolecularweighttoxins
AT richarddietrich electrochemicalbiochipassaysbasedonantiidiotypicantibodiesforrapidandautomatedonsitedetectionoflowmolecularweighttoxins
AT erwinmartlbauer electrochemicalbiochipassaysbasedonantiidiotypicantibodiesforrapidandautomatedonsitedetectionoflowmolecularweighttoxins
AT thomaselßner electrochemicalbiochipassaysbasedonantiidiotypicantibodiesforrapidandautomatedonsitedetectionoflowmolecularweighttoxins