A PEN INJECTOR FOR SELF-ADMINISTRATION OF FOLLITROPIN ALPHA SOLUTION WITH A MINIMAL DOSE INCREMENT OF 5 IU

To date, self administrations of recombinant human follicle-stimulating hormone (rhFSH) are carried out using pen injectors with minimal dose increments of 8.33 IU or 12.5 IU (IU – international units of activity). To ensure the accuracy of dose titration and to minimize the dose adjustments during...

Full description

Bibliographic Details
Main Authors: A. B. Podkorytov, O. V. Zhilyaev, M. A. Polzikov
Format: Article
Language:Russian
Published: IRBIS LLC 2018-02-01
Series:Акушерство, гинекология и репродукция
Subjects:
Online Access:https://www.gynecology.su/jour/article/view/447
_version_ 1797884172224692224
author A. B. Podkorytov
O. V. Zhilyaev
M. A. Polzikov
author_facet A. B. Podkorytov
O. V. Zhilyaev
M. A. Polzikov
author_sort A. B. Podkorytov
collection DOAJ
description To date, self administrations of recombinant human follicle-stimulating hormone (rhFSH) are carried out using pen injectors with minimal dose increments of 8.33 IU or 12.5 IU (IU – international units of activity). To ensure the accuracy of dose titration and to minimize the dose adjustments during the treatment, new pen injectors are needed. Those would provide for the self administration of rhFSH in a wide range of doses and with a dose increment less than the existing fractional values. Aim: to develop a pre-filled, multi-dose pen injector for rhFSH solution with a 5 IU dose increment and a dose setting from 0 to 300 IU.Materials and methods. Dispensed volumes containing the minimal dose of 5 IU were measured gravimetrically.Results. After testing 48 pen injectors the estimated minimal dose of 5 IU (0.0083 ml of the solution) produced the following results: the mean value of the dispensed volume was 0.0081 ml, the mean deviation was ± 0.0006 ml (or ± 0.36 IU). The results are in consistence with the ISO 11608-1:2014(E) requirements of dose accuracy for the minimal dose setting in commercial injectors.Conclusion. We have developed a pen injector for rhFSH administration with a dose setting from 0 to 300 IU and with a minimal increment of dose adjustment of 5 IU. The individual approach to the dose selection/adjustment with a minimal increment of 5 IU may help achieving a highly accurate administration of rhFSH for the controlled ovarian hyperstimulation and for the induced-ovulation protocols with growth activation of 1-2 follicles.
first_indexed 2024-04-10T04:02:16Z
format Article
id doaj.art-fd027c159ec74fd8ac130bc3b5f8bb8a
institution Directory Open Access Journal
issn 2313-7347
2500-3194
language Russian
last_indexed 2024-04-10T04:02:16Z
publishDate 2018-02-01
publisher IRBIS LLC
record_format Article
series Акушерство, гинекология и репродукция
spelling doaj.art-fd027c159ec74fd8ac130bc3b5f8bb8a2023-03-13T07:09:49ZrusIRBIS LLCАкушерство, гинекология и репродукция2313-73472500-31942018-02-01114354210.17749/2313-7347.2017.11.4.035-042419A PEN INJECTOR FOR SELF-ADMINISTRATION OF FOLLITROPIN ALPHA SOLUTION WITH A MINIMAL DOSE INCREMENT OF 5 IUA. B. Podkorytov0O. V. Zhilyaev1M. A. Polzikov2Zavod Medsintez LLC.Zavod Medsintez LLC.IVFarma LLC.To date, self administrations of recombinant human follicle-stimulating hormone (rhFSH) are carried out using pen injectors with minimal dose increments of 8.33 IU or 12.5 IU (IU – international units of activity). To ensure the accuracy of dose titration and to minimize the dose adjustments during the treatment, new pen injectors are needed. Those would provide for the self administration of rhFSH in a wide range of doses and with a dose increment less than the existing fractional values. Aim: to develop a pre-filled, multi-dose pen injector for rhFSH solution with a 5 IU dose increment and a dose setting from 0 to 300 IU.Materials and methods. Dispensed volumes containing the minimal dose of 5 IU were measured gravimetrically.Results. After testing 48 pen injectors the estimated minimal dose of 5 IU (0.0083 ml of the solution) produced the following results: the mean value of the dispensed volume was 0.0081 ml, the mean deviation was ± 0.0006 ml (or ± 0.36 IU). The results are in consistence with the ISO 11608-1:2014(E) requirements of dose accuracy for the minimal dose setting in commercial injectors.Conclusion. We have developed a pen injector for rhFSH administration with a dose setting from 0 to 300 IU and with a minimal increment of dose adjustment of 5 IU. The individual approach to the dose selection/adjustment with a minimal increment of 5 IU may help achieving a highly accurate administration of rhFSH for the controlled ovarian hyperstimulation and for the induced-ovulation protocols with growth activation of 1-2 follicles.https://www.gynecology.su/jour/article/view/447pen injectorfollitropin alpharecombinant follicle-stimulating hormonebiosimilarin vitro fertilizationassisted reproductive technologies
spellingShingle A. B. Podkorytov
O. V. Zhilyaev
M. A. Polzikov
A PEN INJECTOR FOR SELF-ADMINISTRATION OF FOLLITROPIN ALPHA SOLUTION WITH A MINIMAL DOSE INCREMENT OF 5 IU
Акушерство, гинекология и репродукция
pen injector
follitropin alpha
recombinant follicle-stimulating hormone
biosimilar
in vitro fertilization
assisted reproductive technologies
title A PEN INJECTOR FOR SELF-ADMINISTRATION OF FOLLITROPIN ALPHA SOLUTION WITH A MINIMAL DOSE INCREMENT OF 5 IU
title_full A PEN INJECTOR FOR SELF-ADMINISTRATION OF FOLLITROPIN ALPHA SOLUTION WITH A MINIMAL DOSE INCREMENT OF 5 IU
title_fullStr A PEN INJECTOR FOR SELF-ADMINISTRATION OF FOLLITROPIN ALPHA SOLUTION WITH A MINIMAL DOSE INCREMENT OF 5 IU
title_full_unstemmed A PEN INJECTOR FOR SELF-ADMINISTRATION OF FOLLITROPIN ALPHA SOLUTION WITH A MINIMAL DOSE INCREMENT OF 5 IU
title_short A PEN INJECTOR FOR SELF-ADMINISTRATION OF FOLLITROPIN ALPHA SOLUTION WITH A MINIMAL DOSE INCREMENT OF 5 IU
title_sort pen injector for self administration of follitropin alpha solution with a minimal dose increment of 5 iu
topic pen injector
follitropin alpha
recombinant follicle-stimulating hormone
biosimilar
in vitro fertilization
assisted reproductive technologies
url https://www.gynecology.su/jour/article/view/447
work_keys_str_mv AT abpodkorytov apeninjectorforselfadministrationoffollitropinalphasolutionwithaminimaldoseincrementof5iu
AT ovzhilyaev apeninjectorforselfadministrationoffollitropinalphasolutionwithaminimaldoseincrementof5iu
AT mapolzikov apeninjectorforselfadministrationoffollitropinalphasolutionwithaminimaldoseincrementof5iu
AT abpodkorytov peninjectorforselfadministrationoffollitropinalphasolutionwithaminimaldoseincrementof5iu
AT ovzhilyaev peninjectorforselfadministrationoffollitropinalphasolutionwithaminimaldoseincrementof5iu
AT mapolzikov peninjectorforselfadministrationoffollitropinalphasolutionwithaminimaldoseincrementof5iu