Effects of Diagonal Friction Dampers on Behavior of a Building
In this study, the effect of the friction damper location on the earthquake behavior of a building was investigated. Diagonal braced friction dampers were placed on different floors, and the changes in building behavior were examined. For this purpose, a scaled experimental building model with five...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2023-07-01
|
Series: | Applied Sciences |
Subjects: | |
Online Access: | https://www.mdpi.com/2076-3417/13/14/8311 |
_version_ | 1797590416801923072 |
---|---|
author | Emine Aydin Elif Boru Mert Gurbuz |
author_facet | Emine Aydin Elif Boru Mert Gurbuz |
author_sort | Emine Aydin |
collection | DOAJ |
description | In this study, the effect of the friction damper location on the earthquake behavior of a building was investigated. Diagonal braced friction dampers were placed on different floors, and the changes in building behavior were examined. For this purpose, a scaled experimental building model with five floors, with a single span in the x and y directions, was used. Numerical model validation was carried out by taking into account the experimental and numerical period values obtained via the effect of free vibration. The period, peak displacement, and maximum shear force of the friction dampers, arranged in various configurations, were compared using the numerical model in conjunction with three different earthquake acceleration records. According to the investigations, the damper performance of the design changes depending on the earthquake acceleration that is affecting the building. Friction dampers located on the lower floors are more effective at reducing period, peak displacement, and floor shear forces than those located on the upper floors. |
first_indexed | 2024-03-11T01:21:10Z |
format | Article |
id | doaj.art-fd8f7df35be44752ae4e0cefe8db2806 |
institution | Directory Open Access Journal |
issn | 2076-3417 |
language | English |
last_indexed | 2024-03-11T01:21:10Z |
publishDate | 2023-07-01 |
publisher | MDPI AG |
record_format | Article |
series | Applied Sciences |
spelling | doaj.art-fd8f7df35be44752ae4e0cefe8db28062023-11-18T18:11:19ZengMDPI AGApplied Sciences2076-34172023-07-011314831110.3390/app13148311Effects of Diagonal Friction Dampers on Behavior of a BuildingEmine Aydin0Elif Boru1Mert Gurbuz2Civil Engineering Department, Faculty of Technology, Sakarya University of Applied Sciences, Sakarya 54187, TürkiyeCivil Engineering Department, Faculty of Technology, Sakarya University of Applied Sciences, Sakarya 54187, TürkiyeCivil Engineering Department, Faculty of Technology, Sakarya University of Applied Sciences, Sakarya 54187, TürkiyeIn this study, the effect of the friction damper location on the earthquake behavior of a building was investigated. Diagonal braced friction dampers were placed on different floors, and the changes in building behavior were examined. For this purpose, a scaled experimental building model with five floors, with a single span in the x and y directions, was used. Numerical model validation was carried out by taking into account the experimental and numerical period values obtained via the effect of free vibration. The period, peak displacement, and maximum shear force of the friction dampers, arranged in various configurations, were compared using the numerical model in conjunction with three different earthquake acceleration records. According to the investigations, the damper performance of the design changes depending on the earthquake acceleration that is affecting the building. Friction dampers located on the lower floors are more effective at reducing period, peak displacement, and floor shear forces than those located on the upper floors.https://www.mdpi.com/2076-3417/13/14/8311diagonal braced friction damperexperimental modelnumerical modeltime history analysis |
spellingShingle | Emine Aydin Elif Boru Mert Gurbuz Effects of Diagonal Friction Dampers on Behavior of a Building Applied Sciences diagonal braced friction damper experimental model numerical model time history analysis |
title | Effects of Diagonal Friction Dampers on Behavior of a Building |
title_full | Effects of Diagonal Friction Dampers on Behavior of a Building |
title_fullStr | Effects of Diagonal Friction Dampers on Behavior of a Building |
title_full_unstemmed | Effects of Diagonal Friction Dampers on Behavior of a Building |
title_short | Effects of Diagonal Friction Dampers on Behavior of a Building |
title_sort | effects of diagonal friction dampers on behavior of a building |
topic | diagonal braced friction damper experimental model numerical model time history analysis |
url | https://www.mdpi.com/2076-3417/13/14/8311 |
work_keys_str_mv | AT emineaydin effectsofdiagonalfrictiondampersonbehaviorofabuilding AT elifboru effectsofdiagonalfrictiondampersonbehaviorofabuilding AT mertgurbuz effectsofdiagonalfrictiondampersonbehaviorofabuilding |