Modified Modal Pushover Design for Asymmetric-Plan RC Shear-Wall Structures

The goal of this research is to provide a new method for designing reinforced concrete wall structures with a one-way asymmetric plan. This presented method is called the modified modal pushover design method (MMPD), which uses assumptions of modified modal pushover analysis (MMPA) for estimating th...

Full description

Bibliographic Details
Main Authors: Mohammad Sadegh Birzhandi, Daniyal Mirzakhani
Format: Article
Language:English
Published: Hindawi Limited 2023-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2023/5627191
_version_ 1797840115896156160
author Mohammad Sadegh Birzhandi
Daniyal Mirzakhani
author_facet Mohammad Sadegh Birzhandi
Daniyal Mirzakhani
author_sort Mohammad Sadegh Birzhandi
collection DOAJ
description The goal of this research is to provide a new method for designing reinforced concrete wall structures with a one-way asymmetric plan. This presented method is called the modified modal pushover design method (MMPD), which uses assumptions of modified modal pushover analysis (MMPA) for estimating the responses of structures. In summary, the arbitrary distribution of walls’ reinforcements at the beginning of MMPD design steps is modified so that a structure is limited to its selected limit state when analyzed by the MMPA method by knowing that walls’ stiffness is proportional to their corresponding strength. An appropriate hysteretic model (PIVOT model) is selected for the first-mode nonlinear SDOF system so that it estimates the peak and time history displacement response of the roof accurately. Three 8-storey buildings are designed for two different distributions of reinforcement areas to assess their effects on NRHA demands of each story. Higher mode contributions in responses of all structures are calculated by the elastic jagged response spectrum; mean-matched smoothed displacement response spectrum ± standard deviation curve is also used to compare stories’ shear and torsional demands estimated by these two response spectra. The results have shown the accuracy of the MMPD method in calculating the strength and stiffness of seismic-resisting walls.
first_indexed 2024-04-09T16:09:21Z
format Article
id doaj.art-fdb8ba46840446a195b06774a0c7f385
institution Directory Open Access Journal
issn 1687-8094
language English
last_indexed 2024-04-09T16:09:21Z
publishDate 2023-01-01
publisher Hindawi Limited
record_format Article
series Advances in Civil Engineering
spelling doaj.art-fdb8ba46840446a195b06774a0c7f3852023-04-25T00:00:08ZengHindawi LimitedAdvances in Civil Engineering1687-80942023-01-01202310.1155/2023/5627191Modified Modal Pushover Design for Asymmetric-Plan RC Shear-Wall StructuresMohammad Sadegh Birzhandi0Daniyal Mirzakhani1Department of Civil EngineeringShahid Ashrafi Esfahani UniversityThe goal of this research is to provide a new method for designing reinforced concrete wall structures with a one-way asymmetric plan. This presented method is called the modified modal pushover design method (MMPD), which uses assumptions of modified modal pushover analysis (MMPA) for estimating the responses of structures. In summary, the arbitrary distribution of walls’ reinforcements at the beginning of MMPD design steps is modified so that a structure is limited to its selected limit state when analyzed by the MMPA method by knowing that walls’ stiffness is proportional to their corresponding strength. An appropriate hysteretic model (PIVOT model) is selected for the first-mode nonlinear SDOF system so that it estimates the peak and time history displacement response of the roof accurately. Three 8-storey buildings are designed for two different distributions of reinforcement areas to assess their effects on NRHA demands of each story. Higher mode contributions in responses of all structures are calculated by the elastic jagged response spectrum; mean-matched smoothed displacement response spectrum ± standard deviation curve is also used to compare stories’ shear and torsional demands estimated by these two response spectra. The results have shown the accuracy of the MMPD method in calculating the strength and stiffness of seismic-resisting walls.http://dx.doi.org/10.1155/2023/5627191
spellingShingle Mohammad Sadegh Birzhandi
Daniyal Mirzakhani
Modified Modal Pushover Design for Asymmetric-Plan RC Shear-Wall Structures
Advances in Civil Engineering
title Modified Modal Pushover Design for Asymmetric-Plan RC Shear-Wall Structures
title_full Modified Modal Pushover Design for Asymmetric-Plan RC Shear-Wall Structures
title_fullStr Modified Modal Pushover Design for Asymmetric-Plan RC Shear-Wall Structures
title_full_unstemmed Modified Modal Pushover Design for Asymmetric-Plan RC Shear-Wall Structures
title_short Modified Modal Pushover Design for Asymmetric-Plan RC Shear-Wall Structures
title_sort modified modal pushover design for asymmetric plan rc shear wall structures
url http://dx.doi.org/10.1155/2023/5627191
work_keys_str_mv AT mohammadsadeghbirzhandi modifiedmodalpushoverdesignforasymmetricplanrcshearwallstructures
AT daniyalmirzakhani modifiedmodalpushoverdesignforasymmetricplanrcshearwallstructures