Anatomical model for dissection in corpses of the palate vascularization

Introduction: The main artery that supplies the mucoperiosteum of the hard palate is the greater palatine artery. The knowledge detailed of the vascular anatomy of the palate and, in special, of the region of the greater palatine foramen is important for prevention of lesions vascular during procedu...

Full description

Bibliographic Details
Main Authors: Pinheiro Neto, Carlos Diógenes, Ramos, Henrique Faria, Fortes, Felipe Sartor Guimarães, Sennes, Luiz Ubirajara, Alonso, Nivaldo, Brito Neto, Rubens Vuono de
Format: Article
Language:English
Published: Thieme Revinter Publicações Ltda. 2010-03-01
Series:International Archives of Otorhinolaryngology
Subjects:
Online Access:http://www.arquivosdeorl.org.br/conteudo/acervo_eng.asp?id=673
_version_ 1818506788986683392
author Pinheiro Neto, Carlos Diógenes
Ramos, Henrique Faria
Fortes, Felipe Sartor Guimarães
Sennes, Luiz Ubirajara
Alonso, Nivaldo
Brito Neto, Rubens Vuono de
author_facet Pinheiro Neto, Carlos Diógenes
Ramos, Henrique Faria
Fortes, Felipe Sartor Guimarães
Sennes, Luiz Ubirajara
Alonso, Nivaldo
Brito Neto, Rubens Vuono de
author_sort Pinheiro Neto, Carlos Diógenes
collection DOAJ
description Introduction: The main artery that supplies the mucoperiosteum of the hard palate is the greater palatine artery. The knowledge detailed of the vascular anatomy of the palate and, in special, of the region of the greater palatine foramen is important for prevention of lesions vascular during procedures in this region. Among these procedures, it included the making of shreds for correction of failures in the hard palate, soft palate and cranial base. Objective: To develop an anatomical model that can illustrate the endoscopic anatomy of the greater palatine foramen and analyze the technical of injection intra vascular of colored silicone is sufficient for fill the lower arterial branches than irrigate the hard palate. Method: The form of study was experimental through the endoscopic dissection of 10 greater palatine arteries in five heads of corpses prepared with injection intra vascular of colored silicone. Results: Of the total of 10 arteries dissected, 8 properly were colored by the technique of injection employed. What corresponds to an efficacy of 80%. Conclusion: The anatomical model showed to be a feasible approach for the endoscopic study of the greater palatine foramen, being the injection of efficient silicone in the terminals vessels coloring in 80% of the cases.
first_indexed 2024-12-10T22:09:23Z
format Article
id doaj.art-fdd06307975e44fc8175d96e24ecc9b3
institution Directory Open Access Journal
issn 1809-9777
1809-4864
language English
last_indexed 2024-12-10T22:09:23Z
publishDate 2010-03-01
publisher Thieme Revinter Publicações Ltda.
record_format Article
series International Archives of Otorhinolaryngology
spelling doaj.art-fdd06307975e44fc8175d96e24ecc9b32022-12-22T01:31:40ZengThieme Revinter Publicações Ltda.International Archives of Otorhinolaryngology1809-97771809-48642010-03-01141103106Anatomical model for dissection in corpses of the palate vascularizationPinheiro Neto, Carlos DiógenesRamos, Henrique FariaFortes, Felipe Sartor GuimarãesSennes, Luiz UbirajaraAlonso, NivaldoBrito Neto, Rubens Vuono deIntroduction: The main artery that supplies the mucoperiosteum of the hard palate is the greater palatine artery. The knowledge detailed of the vascular anatomy of the palate and, in special, of the region of the greater palatine foramen is important for prevention of lesions vascular during procedures in this region. Among these procedures, it included the making of shreds for correction of failures in the hard palate, soft palate and cranial base. Objective: To develop an anatomical model that can illustrate the endoscopic anatomy of the greater palatine foramen and analyze the technical of injection intra vascular of colored silicone is sufficient for fill the lower arterial branches than irrigate the hard palate. Method: The form of study was experimental through the endoscopic dissection of 10 greater palatine arteries in five heads of corpses prepared with injection intra vascular of colored silicone. Results: Of the total of 10 arteries dissected, 8 properly were colored by the technique of injection employed. What corresponds to an efficacy of 80%. Conclusion: The anatomical model showed to be a feasible approach for the endoscopic study of the greater palatine foramen, being the injection of efficient silicone in the terminals vessels coloring in 80% of the cases.http://www.arquivosdeorl.org.br/conteudo/acervo_eng.asp?id=673CorpsesAnatomyPalatePhysiological Neovascularization
spellingShingle Pinheiro Neto, Carlos Diógenes
Ramos, Henrique Faria
Fortes, Felipe Sartor Guimarães
Sennes, Luiz Ubirajara
Alonso, Nivaldo
Brito Neto, Rubens Vuono de
Anatomical model for dissection in corpses of the palate vascularization
International Archives of Otorhinolaryngology
Corpses
Anatomy
Palate
Physiological Neovascularization
title Anatomical model for dissection in corpses of the palate vascularization
title_full Anatomical model for dissection in corpses of the palate vascularization
title_fullStr Anatomical model for dissection in corpses of the palate vascularization
title_full_unstemmed Anatomical model for dissection in corpses of the palate vascularization
title_short Anatomical model for dissection in corpses of the palate vascularization
title_sort anatomical model for dissection in corpses of the palate vascularization
topic Corpses
Anatomy
Palate
Physiological Neovascularization
url http://www.arquivosdeorl.org.br/conteudo/acervo_eng.asp?id=673
work_keys_str_mv AT pinheironetocarlosdiogenes anatomicalmodelfordissectionincorpsesofthepalatevascularization
AT ramoshenriquefaria anatomicalmodelfordissectionincorpsesofthepalatevascularization
AT fortesfelipesartorguimaraes anatomicalmodelfordissectionincorpsesofthepalatevascularization
AT sennesluizubirajara anatomicalmodelfordissectionincorpsesofthepalatevascularization
AT alonsonivaldo anatomicalmodelfordissectionincorpsesofthepalatevascularization
AT britonetorubensvuonode anatomicalmodelfordissectionincorpsesofthepalatevascularization