Flux-Balance Control for LLC Resonant Converters with Center-Tapped Transformers

LLC resonant converters with center-tapped transformers are widely used. However, these converters suffer from a flux walking issue, which causes a larger output ripple and possible transformer saturation. In this paper, a flux-balance control strategy is proposed for resolving the flux walking issu...

Full description

Bibliographic Details
Main Authors: Yuan-Chih Lin, Ding-Tang Chen, Ching-Jan Chen
Format: Article
Language:English
Published: MDPI AG 2019-08-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/12/17/3211
_version_ 1811185251608690688
author Yuan-Chih Lin
Ding-Tang Chen
Ching-Jan Chen
author_facet Yuan-Chih Lin
Ding-Tang Chen
Ching-Jan Chen
author_sort Yuan-Chih Lin
collection DOAJ
description LLC resonant converters with center-tapped transformers are widely used. However, these converters suffer from a flux walking issue, which causes a larger output ripple and possible transformer saturation. In this paper, a flux-balance control strategy is proposed for resolving the flux walking issue. First, the DC magnetizing current generated due to the mismatched secondary-side leakage inductances, and its effects on the voltage gain are analyzed. From the analysis, the flux-balance control strategy, which is based on the original output-voltage control loop, is proposed. Since the DC magnetizing current is not easily measured, a current sensing strategy with a current estimator is proposed, which only requires one current sensor and is easy to estimate the DC magnetizing current. Finally, a simulation scheme and a hardware prototype with rated output power 200 W, input voltage 380 V, and output voltage 20 V is constructed for verification. The simulation and experimental results show that the proposed control strategy effectively reduces the DC magnetizing current and output voltage ripple at mismatched condition.
first_indexed 2024-04-11T13:27:23Z
format Article
id doaj.art-fe236a2cedee4495b63f60fdc3af6895
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-11T13:27:23Z
publishDate 2019-08-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-fe236a2cedee4495b63f60fdc3af68952022-12-22T04:22:02ZengMDPI AGEnergies1996-10732019-08-011217321110.3390/en12173211en12173211Flux-Balance Control for LLC Resonant Converters with Center-Tapped TransformersYuan-Chih Lin0Ding-Tang Chen1Ching-Jan Chen2Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan; No. 1, Sec. 4, Roosevelt Rd., Taipei 10617, TaiwanDepartment of Electrical Engineering, National Taiwan University, Taipei, Taiwan; No. 1, Sec. 4, Roosevelt Rd., Taipei 10617, TaiwanDepartment of Electrical Engineering, National Taiwan University, Taipei, Taiwan; No. 1, Sec. 4, Roosevelt Rd., Taipei 10617, TaiwanLLC resonant converters with center-tapped transformers are widely used. However, these converters suffer from a flux walking issue, which causes a larger output ripple and possible transformer saturation. In this paper, a flux-balance control strategy is proposed for resolving the flux walking issue. First, the DC magnetizing current generated due to the mismatched secondary-side leakage inductances, and its effects on the voltage gain are analyzed. From the analysis, the flux-balance control strategy, which is based on the original output-voltage control loop, is proposed. Since the DC magnetizing current is not easily measured, a current sensing strategy with a current estimator is proposed, which only requires one current sensor and is easy to estimate the DC magnetizing current. Finally, a simulation scheme and a hardware prototype with rated output power 200 W, input voltage 380 V, and output voltage 20 V is constructed for verification. The simulation and experimental results show that the proposed control strategy effectively reduces the DC magnetizing current and output voltage ripple at mismatched condition.https://www.mdpi.com/1996-1073/12/17/3211LLC resonant convertercenter-tapped transformerflux walkingflux-balance control loopmagnetizing current estimation
spellingShingle Yuan-Chih Lin
Ding-Tang Chen
Ching-Jan Chen
Flux-Balance Control for LLC Resonant Converters with Center-Tapped Transformers
Energies
LLC resonant converter
center-tapped transformer
flux walking
flux-balance control loop
magnetizing current estimation
title Flux-Balance Control for LLC Resonant Converters with Center-Tapped Transformers
title_full Flux-Balance Control for LLC Resonant Converters with Center-Tapped Transformers
title_fullStr Flux-Balance Control for LLC Resonant Converters with Center-Tapped Transformers
title_full_unstemmed Flux-Balance Control for LLC Resonant Converters with Center-Tapped Transformers
title_short Flux-Balance Control for LLC Resonant Converters with Center-Tapped Transformers
title_sort flux balance control for llc resonant converters with center tapped transformers
topic LLC resonant converter
center-tapped transformer
flux walking
flux-balance control loop
magnetizing current estimation
url https://www.mdpi.com/1996-1073/12/17/3211
work_keys_str_mv AT yuanchihlin fluxbalancecontrolforllcresonantconverterswithcentertappedtransformers
AT dingtangchen fluxbalancecontrolforllcresonantconverterswithcentertappedtransformers
AT chingjanchen fluxbalancecontrolforllcresonantconverterswithcentertappedtransformers