Measurement of the area of venous ulcers using two software programs

ABSTRACT Objective: to compare the measurement area of venous ulcers using AutoCAD(r) and Image Tool software. Method: this was an assessment of reproducibility tests conducted in a angiology clinic of a university hospital. Data were collected from 21 patients with venous ulcers, in the period fr...

Full description

Bibliographic Details
Main Authors: Thaís Dresch Eberhardt, Suzinara Beatriz Soares de Lima, Luis Felipe Dias Lopes, Eline de Lima Borges, Teresinha Heck Weiller, Graziele Gorete Portella da Fonseca
Format: Article
Language:English
Published: Universidade de São Paulo
Series:Revista Latino-Americana de Enfermagem
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-11692016000100445&lng=en&tlng=en
_version_ 1818496760244338688
author Thaís Dresch Eberhardt
Suzinara Beatriz Soares de Lima
Luis Felipe Dias Lopes
Eline de Lima Borges
Teresinha Heck Weiller
Graziele Gorete Portella da Fonseca
author_facet Thaís Dresch Eberhardt
Suzinara Beatriz Soares de Lima
Luis Felipe Dias Lopes
Eline de Lima Borges
Teresinha Heck Weiller
Graziele Gorete Portella da Fonseca
author_sort Thaís Dresch Eberhardt
collection DOAJ
description ABSTRACT Objective: to compare the measurement area of venous ulcers using AutoCAD(r) and Image Tool software. Method: this was an assessment of reproducibility tests conducted in a angiology clinic of a university hospital. Data were collected from 21 patients with venous ulcers, in the period from March to July of 2015, using a collection form and photograph of wounds. Five nurses (evaluators) of the hospital skin wound study group participated. The wounds were measured using both software programs. Data were analyzed using intraclass correlation coefficient, concordance correlation coefficient and Bland-Altman analysis. The study met the ethical aspects in accordance with current legislation. Results: the size of ulcers varied widely, however, without significant difference between the measurements; an excellent intraclass and concordance correlation was found between both software programs, which seem to be more accurate when measuring a wound area >10 cm². Conclusion: the use of both software programs is appropriate for measurement of venous ulcers, appearing to be more accurate when used to measure a wound area > 10 cm².
first_indexed 2024-12-10T18:37:00Z
format Article
id doaj.art-fe3231c7ebb74723ad17106f92b6b5f1
institution Directory Open Access Journal
issn 1518-8345
language English
last_indexed 2024-12-10T18:37:00Z
publisher Universidade de São Paulo
record_format Article
series Revista Latino-Americana de Enfermagem
spelling doaj.art-fe3231c7ebb74723ad17106f92b6b5f12022-12-22T01:37:47ZengUniversidade de São PauloRevista Latino-Americana de Enfermagem1518-834524010.1590/1518-8345.1673.2862S0104-11692016000100445Measurement of the area of venous ulcers using two software programsThaís Dresch EberhardtSuzinara Beatriz Soares de LimaLuis Felipe Dias LopesEline de Lima BorgesTeresinha Heck WeillerGraziele Gorete Portella da FonsecaABSTRACT Objective: to compare the measurement area of venous ulcers using AutoCAD(r) and Image Tool software. Method: this was an assessment of reproducibility tests conducted in a angiology clinic of a university hospital. Data were collected from 21 patients with venous ulcers, in the period from March to July of 2015, using a collection form and photograph of wounds. Five nurses (evaluators) of the hospital skin wound study group participated. The wounds were measured using both software programs. Data were analyzed using intraclass correlation coefficient, concordance correlation coefficient and Bland-Altman analysis. The study met the ethical aspects in accordance with current legislation. Results: the size of ulcers varied widely, however, without significant difference between the measurements; an excellent intraclass and concordance correlation was found between both software programs, which seem to be more accurate when measuring a wound area >10 cm². Conclusion: the use of both software programs is appropriate for measurement of venous ulcers, appearing to be more accurate when used to measure a wound area > 10 cm².http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-11692016000100445&lng=en&tlng=enEnfermagemÚlcera VaricosaPesos e MedidasValidação de Programas de Computador
spellingShingle Thaís Dresch Eberhardt
Suzinara Beatriz Soares de Lima
Luis Felipe Dias Lopes
Eline de Lima Borges
Teresinha Heck Weiller
Graziele Gorete Portella da Fonseca
Measurement of the area of venous ulcers using two software programs
Revista Latino-Americana de Enfermagem
Enfermagem
Úlcera Varicosa
Pesos e Medidas
Validação de Programas de Computador
title Measurement of the area of venous ulcers using two software programs
title_full Measurement of the area of venous ulcers using two software programs
title_fullStr Measurement of the area of venous ulcers using two software programs
title_full_unstemmed Measurement of the area of venous ulcers using two software programs
title_short Measurement of the area of venous ulcers using two software programs
title_sort measurement of the area of venous ulcers using two software programs
topic Enfermagem
Úlcera Varicosa
Pesos e Medidas
Validação de Programas de Computador
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0104-11692016000100445&lng=en&tlng=en
work_keys_str_mv AT thaisdrescheberhardt measurementoftheareaofvenousulcersusingtwosoftwareprograms
AT suzinarabeatrizsoaresdelima measurementoftheareaofvenousulcersusingtwosoftwareprograms
AT luisfelipediaslopes measurementoftheareaofvenousulcersusingtwosoftwareprograms
AT elinedelimaborges measurementoftheareaofvenousulcersusingtwosoftwareprograms
AT teresinhaheckweiller measurementoftheareaofvenousulcersusingtwosoftwareprograms
AT grazielegoreteportelladafonseca measurementoftheareaofvenousulcersusingtwosoftwareprograms