Effect observation of human fibrin sealant in the surgery of pterygium

AIM: To compare the efficacy and characteristic of human fibrin sealant in the surgery of pterygium. <p>METHODS: A prospective randomized controlled study was conducted. A total of 148 eyes of 148 patients with pterygium were involved in the study from June 2016 to September 2017. All patients...

Full description

Bibliographic Details
Main Authors: Hong-Yan Sun, Jiang Zhu
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2018-09-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2018/9/201809043.pdf
_version_ 1817981342673010688
author Hong-Yan Sun
Jiang Zhu
author_facet Hong-Yan Sun
Jiang Zhu
author_sort Hong-Yan Sun
collection DOAJ
description AIM: To compare the efficacy and characteristic of human fibrin sealant in the surgery of pterygium. <p>METHODS: A prospective randomized controlled study was conducted. A total of 148 eyes of 148 patients with pterygium were involved in the study from June 2016 to September 2017. All patients were divided into two groups receiving 10-0 vicryl sutures or human fibrin sealant respectively. Patients were seen on postoperative 1, 3d, 1wk, 1, 3, and 6mo after surgery. The duration of surgery, level of patient discomfort, pterygium recurrence, and complications were retrospectively analyzed between two groups. <p>RESULTS: The duration of surgery in observer group was 15.23±2.26min and 28.22±2.70min in control group, the difference was statistically significant(<i>t</i>=-31.75, <i>P</i><0.01). One week later, the level of patient discomfort at 1, 3 and 7d after surgery were 0.62±0.69, 0.34±0.50, 0.16±0.37 in observation group, and the level of patient discomfort were 1.15±0.92, 0.54±0.60, 0.18±0.38 in control group, and the difference were statistically significant in observer group and control group(<i>P</i><0.01); comparison between any two means in either group was significantly different(<i>P</i><0.01). There were significant difference between the two groups on postoperative 1, 3d after surgery(<i>t</i>=-3.94, -2.22; <i>P</i><0.05), and there was not significant difference between the two groups on postoperative 7d after surgery(<i>t</i>=-0.22, <i>P</i>>0.05). Two eyes(2.7%)were recurrent on postoperative 6mo after surgery in observation group and 4 of 74 eyes(5.4%)in control group, demonstrated no significant differences(<i>χ</i><sup>2</sup>=24.2, <i>P</i>>0.05). Five of 74 eyes(6.8%)were with complications in observation group and 6 of 74 eyes(8.1%)in control group, demonstrated no significant differences(<i>χ</i><sup>2</sup>=16.32, <i>P</i>>0.05). <p>CONCLUSION: The duration of surgery, patient discomfort level were reduced markedly, as less flap dislocation and postoperative reaction with human fibrin sealant compared with 10-0 vicryl sutures. A good result can be obtained by using the human fibrin sealant in the surgery of pterygium.
first_indexed 2024-04-13T23:04:40Z
format Article
id doaj.art-ff0008ba51f041f2b5762814cba2364e
institution Directory Open Access Journal
issn 1672-5123
1672-5123
language English
last_indexed 2024-04-13T23:04:40Z
publishDate 2018-09-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series Guoji Yanke Zazhi
spelling doaj.art-ff0008ba51f041f2b5762814cba2364e2022-12-22T02:25:43ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232018-09-011891735173810.3980/j.issn.1672-5123.2018.9.43Effect observation of human fibrin sealant in the surgery of pterygiumHong-Yan Sun0Jiang Zhu1Department of Ophthalmology,Suqian First Hospital, Suqian 223800, Jiangsu Province, ChinaDepartment of Ophthalmology,Suqian First Hospital, Suqian 223800, Jiangsu Province, ChinaAIM: To compare the efficacy and characteristic of human fibrin sealant in the surgery of pterygium. <p>METHODS: A prospective randomized controlled study was conducted. A total of 148 eyes of 148 patients with pterygium were involved in the study from June 2016 to September 2017. All patients were divided into two groups receiving 10-0 vicryl sutures or human fibrin sealant respectively. Patients were seen on postoperative 1, 3d, 1wk, 1, 3, and 6mo after surgery. The duration of surgery, level of patient discomfort, pterygium recurrence, and complications were retrospectively analyzed between two groups. <p>RESULTS: The duration of surgery in observer group was 15.23±2.26min and 28.22±2.70min in control group, the difference was statistically significant(<i>t</i>=-31.75, <i>P</i><0.01). One week later, the level of patient discomfort at 1, 3 and 7d after surgery were 0.62±0.69, 0.34±0.50, 0.16±0.37 in observation group, and the level of patient discomfort were 1.15±0.92, 0.54±0.60, 0.18±0.38 in control group, and the difference were statistically significant in observer group and control group(<i>P</i><0.01); comparison between any two means in either group was significantly different(<i>P</i><0.01). There were significant difference between the two groups on postoperative 1, 3d after surgery(<i>t</i>=-3.94, -2.22; <i>P</i><0.05), and there was not significant difference between the two groups on postoperative 7d after surgery(<i>t</i>=-0.22, <i>P</i>>0.05). Two eyes(2.7%)were recurrent on postoperative 6mo after surgery in observation group and 4 of 74 eyes(5.4%)in control group, demonstrated no significant differences(<i>χ</i><sup>2</sup>=24.2, <i>P</i>>0.05). Five of 74 eyes(6.8%)were with complications in observation group and 6 of 74 eyes(8.1%)in control group, demonstrated no significant differences(<i>χ</i><sup>2</sup>=16.32, <i>P</i>>0.05). <p>CONCLUSION: The duration of surgery, patient discomfort level were reduced markedly, as less flap dislocation and postoperative reaction with human fibrin sealant compared with 10-0 vicryl sutures. A good result can be obtained by using the human fibrin sealant in the surgery of pterygium.http://ies.ijo.cn/cn_publish/2018/9/201809043.pdfpterygiumhuman fibrin sealantduration of surgerylevel of patient discomfortlevel of patient discomfort
spellingShingle Hong-Yan Sun
Jiang Zhu
Effect observation of human fibrin sealant in the surgery of pterygium
Guoji Yanke Zazhi
pterygium
human fibrin sealant
duration of surgery
level of patient discomfort
level of patient discomfort
title Effect observation of human fibrin sealant in the surgery of pterygium
title_full Effect observation of human fibrin sealant in the surgery of pterygium
title_fullStr Effect observation of human fibrin sealant in the surgery of pterygium
title_full_unstemmed Effect observation of human fibrin sealant in the surgery of pterygium
title_short Effect observation of human fibrin sealant in the surgery of pterygium
title_sort effect observation of human fibrin sealant in the surgery of pterygium
topic pterygium
human fibrin sealant
duration of surgery
level of patient discomfort
level of patient discomfort
url http://ies.ijo.cn/cn_publish/2018/9/201809043.pdf
work_keys_str_mv AT hongyansun effectobservationofhumanfibrinsealantinthesurgeryofpterygium
AT jiangzhu effectobservationofhumanfibrinsealantinthesurgeryofpterygium