18F-Fludeoxyglucose absorbed dose estimation in fetus during early pregnancy
The purpose of this study is to assess a rare case of fetal radiation absorbed dose here through 18F-Fludeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) in early pregnancy (5-week-old fetus). The fetal absorbed dose due to the radiation emitted from the mother's bo...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2022-01-01
|
Series: | Journal of Medical Signals and Sensors |
Subjects: | |
Online Access: | http://www.jmssjournal.net/article.asp?issn=2228-7477;year=2022;volume=12;issue=2;spage=171;epage=175;aulast=Ahmadi |
_version_ | 1828777127221133312 |
---|---|
author | Nemat Ahmadi Alireza Karimian Mehdi Nasri Nasrabadi |
author_facet | Nemat Ahmadi Alireza Karimian Mehdi Nasri Nasrabadi |
author_sort | Nemat Ahmadi |
collection | DOAJ |
description | The purpose of this study is to assess a rare case of fetal radiation absorbed dose here through 18F-Fludeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) in early pregnancy (5-week-old fetus). The fetal absorbed dose due to the radiation emitted from the mother's body, the fetus self-dose, and the dose received from CT were computed. The 35-year-old patient, weighing 85 kg, was injected with 370 MBq of 18F-FDG. Imaging started at 1 h with CT acquisition followed by PET imaging. The photon and positron self-dose was calculated by applying the Monte Carlo (MC) GATE (GEANT 4 Application for Tomographic Emission) code. The volume of absorbed dose from the mother's body organs and the absorbed dose from the CT were added to the self-dose to obtain the final dose. The volume of self-dose obtained through MC simulation for the fetus was 3.3 × 10-2 mGy/MBq, of which 2.97 × 10-2 mGy/MBq was associated with positrons and 0.33 × 10-2 mGy/MBq was associated with photons. Biologically, the absorbed dose from CT, 7.3 mGy, had to be added to the total dose. The absorbed dose by the fetus during early pregnancy was higher than the standard value of 2.2 × 10-2 mGy/MBq (MIRD DER) because, during the examinations, the mother's bladder was full. This issue was a concern during updating standards. |
first_indexed | 2024-12-11T16:15:19Z |
format | Article |
id | doaj.art-ff49a9020e9d4f1bae1611ff70a3bb3b |
institution | Directory Open Access Journal |
issn | 2228-7477 |
language | English |
last_indexed | 2024-12-11T16:15:19Z |
publishDate | 2022-01-01 |
publisher | Wolters Kluwer Medknow Publications |
record_format | Article |
series | Journal of Medical Signals and Sensors |
spelling | doaj.art-ff49a9020e9d4f1bae1611ff70a3bb3b2022-12-22T00:58:59ZengWolters Kluwer Medknow PublicationsJournal of Medical Signals and Sensors2228-74772022-01-0112217117510.4103/jmss.JMSS_70_2018F-Fludeoxyglucose absorbed dose estimation in fetus during early pregnancyNemat AhmadiAlireza KarimianMehdi Nasri NasrabadiThe purpose of this study is to assess a rare case of fetal radiation absorbed dose here through 18F-Fludeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) in early pregnancy (5-week-old fetus). The fetal absorbed dose due to the radiation emitted from the mother's body, the fetus self-dose, and the dose received from CT were computed. The 35-year-old patient, weighing 85 kg, was injected with 370 MBq of 18F-FDG. Imaging started at 1 h with CT acquisition followed by PET imaging. The photon and positron self-dose was calculated by applying the Monte Carlo (MC) GATE (GEANT 4 Application for Tomographic Emission) code. The volume of absorbed dose from the mother's body organs and the absorbed dose from the CT were added to the self-dose to obtain the final dose. The volume of self-dose obtained through MC simulation for the fetus was 3.3 × 10-2 mGy/MBq, of which 2.97 × 10-2 mGy/MBq was associated with positrons and 0.33 × 10-2 mGy/MBq was associated with photons. Biologically, the absorbed dose from CT, 7.3 mGy, had to be added to the total dose. The absorbed dose by the fetus during early pregnancy was higher than the standard value of 2.2 × 10-2 mGy/MBq (MIRD DER) because, during the examinations, the mother's bladder was full. This issue was a concern during updating standards.http://www.jmssjournal.net/article.asp?issn=2228-7477;year=2022;volume=12;issue=2;spage=171;epage=175;aulast=Ahmadi18f-fludeoxyglucosefetusgatematernal dosemonte carlo simulationpositron emission tomography/computed tomographypregnancy |
spellingShingle | Nemat Ahmadi Alireza Karimian Mehdi Nasri Nasrabadi 18F-Fludeoxyglucose absorbed dose estimation in fetus during early pregnancy Journal of Medical Signals and Sensors 18f-fludeoxyglucose fetus gate maternal dose monte carlo simulation positron emission tomography/computed tomography pregnancy |
title | 18F-Fludeoxyglucose absorbed dose estimation in fetus during early pregnancy |
title_full | 18F-Fludeoxyglucose absorbed dose estimation in fetus during early pregnancy |
title_fullStr | 18F-Fludeoxyglucose absorbed dose estimation in fetus during early pregnancy |
title_full_unstemmed | 18F-Fludeoxyglucose absorbed dose estimation in fetus during early pregnancy |
title_short | 18F-Fludeoxyglucose absorbed dose estimation in fetus during early pregnancy |
title_sort | 18f fludeoxyglucose absorbed dose estimation in fetus during early pregnancy |
topic | 18f-fludeoxyglucose fetus gate maternal dose monte carlo simulation positron emission tomography/computed tomography pregnancy |
url | http://www.jmssjournal.net/article.asp?issn=2228-7477;year=2022;volume=12;issue=2;spage=171;epage=175;aulast=Ahmadi |
work_keys_str_mv | AT nematahmadi 18ffludeoxyglucoseabsorbeddoseestimationinfetusduringearlypregnancy AT alirezakarimian 18ffludeoxyglucoseabsorbeddoseestimationinfetusduringearlypregnancy AT mehdinasrinasrabadi 18ffludeoxyglucoseabsorbeddoseestimationinfetusduringearlypregnancy |