Torsional behavior of reinforced concrete T-beams strengthened with CFRP strips

Torsion is resisted well by locked system of reinforcement, due to the blood nature of the torsion induced-shear flow stresses in a beam. Therefore, it will be more effective to have strengthening schemes, which are wrapped in closed form around the cross section. But strengthening with U wrap (thre...

Full description

Bibliographic Details
Main Author: Rafid Saeed Atea
Format: Article
Language:English
Published: Elsevier 2017-12-01
Series:Case Studies in Construction Materials
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214509517300232
_version_ 1819117630391320576
author Rafid Saeed Atea
author_facet Rafid Saeed Atea
author_sort Rafid Saeed Atea
collection DOAJ
description Torsion is resisted well by locked system of reinforcement, due to the blood nature of the torsion induced-shear flow stresses in a beam. Therefore, it will be more effective to have strengthening schemes, which are wrapped in closed form around the cross section. But strengthening with U wrap (three sides) or strengthening in the web and flange unconnectedly is more useful because of the unreachability of the entire cross section due to addition of flange in uniform beam – slab construction (T section of interior beam). This work aims at studying the strengthening of T beams in torsion by using carbon fiber reinforced polymer (CFRP). The CFRP laminates will be used for strengthening previous to loading. The experimental work includes investigation of twelve reinforced concrete T beams tested under pure torsion. The first beam was the reference beam, without CFRP. The second beam was a simple concrete beam. The remaining ten beams. Variables considered in the test program include; effect of flange strengthening, effect of fiber orientation (90° or 45° CFRP strips with respect to the longitudinal axis), effect of using additional longitudinal CFRP strips with transverse CFRP strips, effect of bolt anchoring CFRP strips in the web and flange and effect of continuous CFRP strips between web and flange (isolated T section). Test results were discussed based on torque – twist behavior, beam elongations, CFRP strain, concrete strain and influence of CFRP on cracking torque, ultimate torque and failure modes.
first_indexed 2024-12-22T05:36:02Z
format Article
id doaj.art-ff6c0ad68cc842dd86c5e0de023d5190
institution Directory Open Access Journal
issn 2214-5095
language English
last_indexed 2024-12-22T05:36:02Z
publishDate 2017-12-01
publisher Elsevier
record_format Article
series Case Studies in Construction Materials
spelling doaj.art-ff6c0ad68cc842dd86c5e0de023d51902022-12-21T18:37:20ZengElsevierCase Studies in Construction Materials2214-50952017-12-017C11011710.1016/j.cscm.2017.03.002Torsional behavior of reinforced concrete T-beams strengthened with CFRP stripsRafid Saeed AteaTorsion is resisted well by locked system of reinforcement, due to the blood nature of the torsion induced-shear flow stresses in a beam. Therefore, it will be more effective to have strengthening schemes, which are wrapped in closed form around the cross section. But strengthening with U wrap (three sides) or strengthening in the web and flange unconnectedly is more useful because of the unreachability of the entire cross section due to addition of flange in uniform beam – slab construction (T section of interior beam). This work aims at studying the strengthening of T beams in torsion by using carbon fiber reinforced polymer (CFRP). The CFRP laminates will be used for strengthening previous to loading. The experimental work includes investigation of twelve reinforced concrete T beams tested under pure torsion. The first beam was the reference beam, without CFRP. The second beam was a simple concrete beam. The remaining ten beams. Variables considered in the test program include; effect of flange strengthening, effect of fiber orientation (90° or 45° CFRP strips with respect to the longitudinal axis), effect of using additional longitudinal CFRP strips with transverse CFRP strips, effect of bolt anchoring CFRP strips in the web and flange and effect of continuous CFRP strips between web and flange (isolated T section). Test results were discussed based on torque – twist behavior, beam elongations, CFRP strain, concrete strain and influence of CFRP on cracking torque, ultimate torque and failure modes.http://www.sciencedirect.com/science/article/pii/S2214509517300232Composite constructionReinforced concrete beamT-beam sectionCarbon fiber Reinforced polymerMid-span deflection
spellingShingle Rafid Saeed Atea
Torsional behavior of reinforced concrete T-beams strengthened with CFRP strips
Case Studies in Construction Materials
Composite construction
Reinforced concrete beam
T-beam section
Carbon fiber Reinforced polymer
Mid-span deflection
title Torsional behavior of reinforced concrete T-beams strengthened with CFRP strips
title_full Torsional behavior of reinforced concrete T-beams strengthened with CFRP strips
title_fullStr Torsional behavior of reinforced concrete T-beams strengthened with CFRP strips
title_full_unstemmed Torsional behavior of reinforced concrete T-beams strengthened with CFRP strips
title_short Torsional behavior of reinforced concrete T-beams strengthened with CFRP strips
title_sort torsional behavior of reinforced concrete t beams strengthened with cfrp strips
topic Composite construction
Reinforced concrete beam
T-beam section
Carbon fiber Reinforced polymer
Mid-span deflection
url http://www.sciencedirect.com/science/article/pii/S2214509517300232
work_keys_str_mv AT rafidsaeedatea torsionalbehaviorofreinforcedconcretetbeamsstrengthenedwithcfrpstrips