Method for barometers calibration based on radiosonde observations

A new method to calibrate fixed and portable barometers is described and tested: The method is based on data from the World Net of Radiosonde (WNR). The World Meteorological Organization (WMO) coordinates the WRN operations. A demonstration of the method that includes the calibration of a pair of ba...

Full description

Bibliographic Details
Main Author: Luis Hidalgo
Format: Article
Language:English
Published: Universidad del Zulia 2010-12-01
Series:Revista Técnica de la Facultad de Ingeniería
Subjects:
Online Access:https://www.produccioncientificaluz.org/index.php/tecnica/article/view/5736
_version_ 1811201888638468096
author Luis Hidalgo
author_facet Luis Hidalgo
author_sort Luis Hidalgo
collection DOAJ
description A new method to calibrate fixed and portable barometers is described and tested: The method is based on data from the World Net of Radiosonde (WNR). The World Meteorological Organization (WMO) coordinates the WRN operations. A demonstration of the method that includes the calibration of a pair of barometers used jointly gave a standard estimation error of Ó0.49 hPa (1014-779 hPa). The level of that error permits the use of the pair in meteorological applications. An additional test of validation was undertaken successfully. The method was developed for the continental equatorial area of South America, although, there is no restrictions to its use in other tropical areas covered by the WNR.
first_indexed 2024-04-12T02:29:31Z
format Article
id doaj.art-ff819b215ef048ecb0df0e9343c118b1
institution Directory Open Access Journal
issn 0254-0770
2477-9377
language English
last_indexed 2024-04-12T02:29:31Z
publishDate 2010-12-01
publisher Universidad del Zulia
record_format Article
series Revista Técnica de la Facultad de Ingeniería
spelling doaj.art-ff819b215ef048ecb0df0e9343c118b12022-12-22T03:51:51ZengUniversidad del ZuliaRevista Técnica de la Facultad de Ingeniería0254-07702477-93772010-12-01242Method for barometers calibration based on radiosonde observationsLuis Hidalgo0Universidad Central de VenezuelaA new method to calibrate fixed and portable barometers is described and tested: The method is based on data from the World Net of Radiosonde (WNR). The World Meteorological Organization (WMO) coordinates the WRN operations. A demonstration of the method that includes the calibration of a pair of barometers used jointly gave a standard estimation error of Ó0.49 hPa (1014-779 hPa). The level of that error permits the use of the pair in meteorological applications. An additional test of validation was undertaken successfully. The method was developed for the continental equatorial area of South America, although, there is no restrictions to its use in other tropical areas covered by the WNR. https://www.produccioncientificaluz.org/index.php/tecnica/article/view/5736calibrationbarometerradiosondeSouth America
spellingShingle Luis Hidalgo
Method for barometers calibration based on radiosonde observations
Revista Técnica de la Facultad de Ingeniería
calibration
barometer
radiosonde
South America
title Method for barometers calibration based on radiosonde observations
title_full Method for barometers calibration based on radiosonde observations
title_fullStr Method for barometers calibration based on radiosonde observations
title_full_unstemmed Method for barometers calibration based on radiosonde observations
title_short Method for barometers calibration based on radiosonde observations
title_sort method for barometers calibration based on radiosonde observations
topic calibration
barometer
radiosonde
South America
url https://www.produccioncientificaluz.org/index.php/tecnica/article/view/5736
work_keys_str_mv AT luishidalgo methodforbarometerscalibrationbasedonradiosondeobservations