Enhancing Measurement Quality of Voltage Divider Circuit and ACS712 DC Current Sensor in PPNS Baruna 01 Crewboat Solar Power Plant

This research explores the crucial role of precise measurement in enhancing solar power generation efficiency within the maritime context, with a specific focus on the solar power plant aboard the PPNS Baruna 01 Crewboat. It investigates the relationship between light intensity and solar cell voltag...

Full description

Bibliographic Details
Main Authors: Santoso Mardi, Putra Zindhu Maulana Ahmad, Nugraha Anggara Trisna, Najudah Faiqotin, Firdiansyah Rahmania
Format: Article
Language:English
Published: EDP Sciences 2024-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2024/03/e3sconf_i-core2024_01009.pdf
Description
Summary:This research explores the crucial role of precise measurement in enhancing solar power generation efficiency within the maritime context, with a specific focus on the solar power plant aboard the PPNS Baruna 01 Crewboat. It investigates the relationship between light intensity and solar cell voltage output, affirming the direct correlation between sunlight availability and voltage generation. Additionally, the study introduces the application of simple linear regression techniques to improve measurement accuracy, particularly in voltage divider circuits and ACS712 current sensors. Results demonstrate a substantial reduction in measurement errors, from 34.88% to 0.45% for voltage measurement and from 23.71% to 2.69% for current measurement. These advancements hold significant implications for the maritime industry, promoting the adoption of clean and renewable solar energy sources on vessels, potentially reducing reliance on fossil fuels, and contributing to environmental sustainability. Moreover, the research underscores the importance of data analysis in optimizing energy systems and provides a foundation for further developments in renewable energy technology and system optimization.
ISSN:2267-1242