Prospective study to compare the dose distribution and acute toxicity of three-dimentional conformal radiation therapy with intensity-modulated radiation therapy for post-mastectomy radiotherapy in carcinoma breast

Though adjuvant radiotherapy has an established role in the treatment of carcinoma breast, there is concern regarding irradiation to heart and lung, more on left sided disease. Intensity Modulated Radiation Therapy (IMRT) modulates the intensity of the radiation beams with better accuracy, sparing s...

Full description

Bibliographic Details
Main Authors: Chakraborty S, Sharma S, Maji A, Biswas L, Mandal S
Format: Article
Language:English
Published: KIMS Foundation and Research Center 2022-07-01
Series:Journal of Medical and Scientific Research
Subjects:
Online Access:http://jmsronline.com/archive-article/Acute-toxicity-of-three-dimentional-conformal-radiation-therapy-intensity-modulated%20radiation%20therapy
_version_ 1797905019805106176
author Chakraborty S
Sharma S
Maji A
Biswas L
Mandal S
author_facet Chakraborty S
Sharma S
Maji A
Biswas L
Mandal S
author_sort Chakraborty S
collection DOAJ
description Though adjuvant radiotherapy has an established role in the treatment of carcinoma breast, there is concern regarding irradiation to heart and lung, more on left sided disease. Intensity Modulated Radiation Therapy (IMRT) modulates the intensity of the radiation beams with better accuracy, sparing surrounding normal organs. But it increases integral dose to normal healthy tissues compared to 3-Dimensional Conformal Radiation Therapy (3DCRT). So, our study was aimed at comparing the dosimetry and acute toxicity profile of 3DCRT and IMRT in post-mastectomy patients. In study arm patients received radiotherapy with IMRT and in control arm with 3DCRT, radiation dose being 50 Gy in 25 fractions for 5 weeks for both the arms. We compared the dosimetric data for Planning Target Volume (PTV) and Organ At-risk (OAR) by both techniques along with acute toxicity profile. Dosimetric parameter of PTV coverage V95 and V107 were significantly better in IMRT than 3DCRT (p-value <0.0001). IMRT showed better homogeneity index (0.14 Gy vs 0.26 Gy) and conformity index was also better for IMRT (0.94 Gy vs 0.74 Gy, p-value 0.0028). The mean value of heart V25 in left sided disease was significantly lower in IMRT than 3DCRT (22.59 and 25.64, p value 0.01). V20 of ipsilateral lung was numerically less in IMRT though not significant (31.44 vs 35.3). But low dose volume was significantly more in IMRT, as seen by higher V5 of heart and ipsilateral lung. To conclude, IMRT has better PTV coverage and better sparing of organs at risk with more homogenous and conformal plans than 3DCRT.
first_indexed 2024-04-10T09:58:22Z
format Article
id doaj.art-ffd5cb288e9b44e5b427625e05fd0a0b
institution Directory Open Access Journal
issn 2321-1326
2394-112X
language English
last_indexed 2024-04-10T09:58:22Z
publishDate 2022-07-01
publisher KIMS Foundation and Research Center
record_format Article
series Journal of Medical and Scientific Research
spelling doaj.art-ffd5cb288e9b44e5b427625e05fd0a0b2023-02-16T11:51:35ZengKIMS Foundation and Research CenterJournal of Medical and Scientific Research2321-13262394-112X2022-07-0110313314010.17727/JMSR.2022/10-25Prospective study to compare the dose distribution and acute toxicity of three-dimentional conformal radiation therapy with intensity-modulated radiation therapy for post-mastectomy radiotherapy in carcinoma breastChakraborty S0Sharma S1Maji A2Biswas L3Mandal S4Department of Radiotherapy, Nil Ratan Sircar Medical College and Hospital, Sealdah, Raja Bazar, Kolkata, West Bengal-700014, India Department of Radiotherapy, North Bengal Medical College and Hospital, Sushruta Nagar, West Bengal-734012, IndiaDepartment of Radiotherapy, Nil Ratan Sircar Medical College and Hospital, Sealdah, Raja Bazar, Kolkata, West Bengal-700014, India Department of Radiotherapy, Nil Ratan Sircar Medical College and Hospital, Sealdah, Raja Bazar, Kolkata, West Bengal-700014, India Department of Radiotherapy, Nil Ratan Sircar Medical College and Hospital, Sealdah, Raja Bazar, Kolkata, West Bengal-700014, India Though adjuvant radiotherapy has an established role in the treatment of carcinoma breast, there is concern regarding irradiation to heart and lung, more on left sided disease. Intensity Modulated Radiation Therapy (IMRT) modulates the intensity of the radiation beams with better accuracy, sparing surrounding normal organs. But it increases integral dose to normal healthy tissues compared to 3-Dimensional Conformal Radiation Therapy (3DCRT). So, our study was aimed at comparing the dosimetry and acute toxicity profile of 3DCRT and IMRT in post-mastectomy patients. In study arm patients received radiotherapy with IMRT and in control arm with 3DCRT, radiation dose being 50 Gy in 25 fractions for 5 weeks for both the arms. We compared the dosimetric data for Planning Target Volume (PTV) and Organ At-risk (OAR) by both techniques along with acute toxicity profile. Dosimetric parameter of PTV coverage V95 and V107 were significantly better in IMRT than 3DCRT (p-value <0.0001). IMRT showed better homogeneity index (0.14 Gy vs 0.26 Gy) and conformity index was also better for IMRT (0.94 Gy vs 0.74 Gy, p-value 0.0028). The mean value of heart V25 in left sided disease was significantly lower in IMRT than 3DCRT (22.59 and 25.64, p value 0.01). V20 of ipsilateral lung was numerically less in IMRT though not significant (31.44 vs 35.3). But low dose volume was significantly more in IMRT, as seen by higher V5 of heart and ipsilateral lung. To conclude, IMRT has better PTV coverage and better sparing of organs at risk with more homogenous and conformal plans than 3DCRT. http://jmsronline.com/archive-article/Acute-toxicity-of-three-dimentional-conformal-radiation-therapy-intensity-modulated%20radiation%20therapyadjuvant radiotherapyimrt3dcrtcarcinoma breast
spellingShingle Chakraborty S
Sharma S
Maji A
Biswas L
Mandal S
Prospective study to compare the dose distribution and acute toxicity of three-dimentional conformal radiation therapy with intensity-modulated radiation therapy for post-mastectomy radiotherapy in carcinoma breast
Journal of Medical and Scientific Research
adjuvant radiotherapy
imrt
3dcrt
carcinoma breast
title Prospective study to compare the dose distribution and acute toxicity of three-dimentional conformal radiation therapy with intensity-modulated radiation therapy for post-mastectomy radiotherapy in carcinoma breast
title_full Prospective study to compare the dose distribution and acute toxicity of three-dimentional conformal radiation therapy with intensity-modulated radiation therapy for post-mastectomy radiotherapy in carcinoma breast
title_fullStr Prospective study to compare the dose distribution and acute toxicity of three-dimentional conformal radiation therapy with intensity-modulated radiation therapy for post-mastectomy radiotherapy in carcinoma breast
title_full_unstemmed Prospective study to compare the dose distribution and acute toxicity of three-dimentional conformal radiation therapy with intensity-modulated radiation therapy for post-mastectomy radiotherapy in carcinoma breast
title_short Prospective study to compare the dose distribution and acute toxicity of three-dimentional conformal radiation therapy with intensity-modulated radiation therapy for post-mastectomy radiotherapy in carcinoma breast
title_sort prospective study to compare the dose distribution and acute toxicity of three dimentional conformal radiation therapy with intensity modulated radiation therapy for post mastectomy radiotherapy in carcinoma breast
topic adjuvant radiotherapy
imrt
3dcrt
carcinoma breast
url http://jmsronline.com/archive-article/Acute-toxicity-of-three-dimentional-conformal-radiation-therapy-intensity-modulated%20radiation%20therapy
work_keys_str_mv AT chakrabortys prospectivestudytocomparethedosedistributionandacutetoxicityofthreedimentionalconformalradiationtherapywithintensitymodulatedradiationtherapyforpostmastectomyradiotherapyincarcinomabreast
AT sharmas prospectivestudytocomparethedosedistributionandacutetoxicityofthreedimentionalconformalradiationtherapywithintensitymodulatedradiationtherapyforpostmastectomyradiotherapyincarcinomabreast
AT majia prospectivestudytocomparethedosedistributionandacutetoxicityofthreedimentionalconformalradiationtherapywithintensitymodulatedradiationtherapyforpostmastectomyradiotherapyincarcinomabreast
AT biswasl prospectivestudytocomparethedosedistributionandacutetoxicityofthreedimentionalconformalradiationtherapywithintensitymodulatedradiationtherapyforpostmastectomyradiotherapyincarcinomabreast
AT mandals prospectivestudytocomparethedosedistributionandacutetoxicityofthreedimentionalconformalradiationtherapywithintensitymodulatedradiationtherapyforpostmastectomyradiotherapyincarcinomabreast