Effectiveness of a measure program to prevent admission hypothermia in very low-birth weight preterm infants

Objective: To evaluate the effectiveness of a thermoregulation bundle for preventing admission hypothermia in very low-birth weight preterm infants. Methods: Interventional study with retrospective evaluation of data undertaken in a tertiary neonatal unit including all very low-birth weight preterm...

Full description

Bibliographic Details
Main Authors: Jamil Pedro de Siqueira Caldas, Fernanda de Castro Millen, Juliana Fernandes de Camargo, Paula Almeida Cavalcanti Castro, Ana Letícia da Fonseca Camilo, Sérgio Tadeu Martins Marba
Format: Article
Language:English
Published: Elsevier 2018-07-01
Series:Jornal de Pediatria
Online Access:http://www.sciencedirect.com/science/article/pii/S0021755717303078
_version_ 1798037820388933632
author Jamil Pedro de Siqueira Caldas
Fernanda de Castro Millen
Juliana Fernandes de Camargo
Paula Almeida Cavalcanti Castro
Ana Letícia da Fonseca Camilo
Sérgio Tadeu Martins Marba
author_facet Jamil Pedro de Siqueira Caldas
Fernanda de Castro Millen
Juliana Fernandes de Camargo
Paula Almeida Cavalcanti Castro
Ana Letícia da Fonseca Camilo
Sérgio Tadeu Martins Marba
author_sort Jamil Pedro de Siqueira Caldas
collection DOAJ
description Objective: To evaluate the effectiveness of a thermoregulation bundle for preventing admission hypothermia in very low-birth weight preterm infants. Methods: Interventional study with retrospective evaluation of data undertaken in a tertiary neonatal unit including all very low-birth weight preterm infants (<1500 g) born at and admitted to the unit. Two periods were compared: before intervention (PI; 01/01/2012 to 02/28/2014_ and after intervention (PII; 04/01/2014 to 11/30/2016). The intervention started in March 2014. At PI procedures in the delivery room were: placement in a crib with a radiant heat source, doors always closed, polyethylene body plastic bag, double cap (plastic and cotton mesh), room temperature between 24 to 27 °C and transport to neonatal unit in a pre-heated incubator (36–37.0 °C). At PII, there was a reinforcement on not opening the plastic bag during the entire resuscitation process, even at an advanced stage, and the anthropometric measures and routine care were performed in the neonatal unit. Maternal, delivery, and neonatal variables were compared. Admission hypothermia was considered when admission axillary temperature was <36.0 °C. Periodic results were shown to the team every six months and results were discussed. Results: The incidence of admission hypothermia was reduced significantly in PII (37.2 vs. 14.2%, p < 0.0001) and admission temperature medians were higher (36.1 vs. 36.5 °C, p < 0.001). At PII, there was an increase in the number of infants transported with oxygen (49.5 vs. 75.5%, p < 0.0001). No differences were observed regarding birth weight and gestational age. Conclusion: There was a very important reduction in admission hypothermia incidence and a higher median admission temperature after continued protocol implementation. Resumo: Objetivo: Avaliar a efetividade de um programa de medidas para prevenção de hipotermia à admissão em recém-nascidos pré-termo de muito baixo peso. Métodos: Estudo de intervenção com coleta retrospectiva de dados em unidade neonatal terciária que incluiu todos os recém-nascidos pré-termo de muito baixo peso (< 1.500 g) nascidos e admitidos na unidade. Foram comparados dois períodos: antes da intervenção PI - 01/01/2012 a 28/02/2014 e depois da intervenção PII - 01/04/2014 a 30/11/2016. O mês de março de 2014 foi o início da intervenção. Em PI as medidas em sala de parto foram: recepção em berço de calor radiante, portas sempre fechadas, uso de saco plástico corporal, colocação de dupla touca (plástico e malha) na cabeça, temperatura ambiental entre 24-27 °C e transporte em incubadora aquecida (36-37,0 °C). No PII reforçou-se a não abertura do saco plástico durante toda reanimação mesmo que avançada e dados antropométricos e cuidados rotineiros realizados na unidade de internação. Variáveis maternas, de parto e neonatais foram comparadas entre os dois períodos. A hipotermia à admissão foi considerada quando temperatura axilar < 36,0 °C. Resultados parciais foram apresentados e discutidos com a equipe semestralmente. Resultados: A incidência da hipotermia à admissão diminuiu significativamente em PII (37,2 x14,2%, p < 0,0001) e a mediana de temperatura foi mais elevada (36,1x36,5° C, p < 0,001). Houve aumento significativo do número de crianças transportadas com oxigênio em PII (49,5 x 75,5%, p < 0,0001). Não houve diferenças para peso ao nascer e idade gestacional. Conclusão: Houve redução acentuada de hipotermia à admissão e melhora na mediana da temperatura de admissão hospitalar em recém-nascidos pré-termo de muito baixo peso após implantação do protocolo. Keywords: Hypothermia, Very low birth weight infant, Quality of health care, Palavras-chave: Hipotermia, Recém-nascido de muito baixo peso, Qualidade da assistência à saúde
first_indexed 2024-04-11T21:31:46Z
format Article
id doaj.art-ffda8de60e284df3b8a64df7d4bc742a
institution Directory Open Access Journal
issn 0021-7557
language English
last_indexed 2024-04-11T21:31:46Z
publishDate 2018-07-01
publisher Elsevier
record_format Article
series Jornal de Pediatria
spelling doaj.art-ffda8de60e284df3b8a64df7d4bc742a2022-12-22T04:01:56ZengElsevierJornal de Pediatria0021-75572018-07-01944368373Effectiveness of a measure program to prevent admission hypothermia in very low-birth weight preterm infantsJamil Pedro de Siqueira Caldas0Fernanda de Castro Millen1Juliana Fernandes de Camargo2Paula Almeida Cavalcanti Castro3Ana Letícia da Fonseca Camilo4Sérgio Tadeu Martins Marba5Universidade Estadual de Campinas (UNICAMP), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, Brazil; Corresponding author.Universidade Estadual de Campinas (UNICAMP), Centro de Atenção Integral à Saúde da Mulher (CAISM), Divisão de Neonatologia, Campinas, SP, BrazilUniversidade Estadual de Campinas (UNICAMP), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, BrazilUniversidade Estadual de Campinas (UNICAMP), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, BrazilUniversidade Estadual de Campinas (UNICAMP), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, BrazilUniversidade Estadual de Campinas (UNICAMP), Faculdade de Ciências Médicas, Departamento de Pediatria, Campinas, SP, BrazilObjective: To evaluate the effectiveness of a thermoregulation bundle for preventing admission hypothermia in very low-birth weight preterm infants. Methods: Interventional study with retrospective evaluation of data undertaken in a tertiary neonatal unit including all very low-birth weight preterm infants (<1500 g) born at and admitted to the unit. Two periods were compared: before intervention (PI; 01/01/2012 to 02/28/2014_ and after intervention (PII; 04/01/2014 to 11/30/2016). The intervention started in March 2014. At PI procedures in the delivery room were: placement in a crib with a radiant heat source, doors always closed, polyethylene body plastic bag, double cap (plastic and cotton mesh), room temperature between 24 to 27 °C and transport to neonatal unit in a pre-heated incubator (36–37.0 °C). At PII, there was a reinforcement on not opening the plastic bag during the entire resuscitation process, even at an advanced stage, and the anthropometric measures and routine care were performed in the neonatal unit. Maternal, delivery, and neonatal variables were compared. Admission hypothermia was considered when admission axillary temperature was <36.0 °C. Periodic results were shown to the team every six months and results were discussed. Results: The incidence of admission hypothermia was reduced significantly in PII (37.2 vs. 14.2%, p < 0.0001) and admission temperature medians were higher (36.1 vs. 36.5 °C, p < 0.001). At PII, there was an increase in the number of infants transported with oxygen (49.5 vs. 75.5%, p < 0.0001). No differences were observed regarding birth weight and gestational age. Conclusion: There was a very important reduction in admission hypothermia incidence and a higher median admission temperature after continued protocol implementation. Resumo: Objetivo: Avaliar a efetividade de um programa de medidas para prevenção de hipotermia à admissão em recém-nascidos pré-termo de muito baixo peso. Métodos: Estudo de intervenção com coleta retrospectiva de dados em unidade neonatal terciária que incluiu todos os recém-nascidos pré-termo de muito baixo peso (< 1.500 g) nascidos e admitidos na unidade. Foram comparados dois períodos: antes da intervenção PI - 01/01/2012 a 28/02/2014 e depois da intervenção PII - 01/04/2014 a 30/11/2016. O mês de março de 2014 foi o início da intervenção. Em PI as medidas em sala de parto foram: recepção em berço de calor radiante, portas sempre fechadas, uso de saco plástico corporal, colocação de dupla touca (plástico e malha) na cabeça, temperatura ambiental entre 24-27 °C e transporte em incubadora aquecida (36-37,0 °C). No PII reforçou-se a não abertura do saco plástico durante toda reanimação mesmo que avançada e dados antropométricos e cuidados rotineiros realizados na unidade de internação. Variáveis maternas, de parto e neonatais foram comparadas entre os dois períodos. A hipotermia à admissão foi considerada quando temperatura axilar < 36,0 °C. Resultados parciais foram apresentados e discutidos com a equipe semestralmente. Resultados: A incidência da hipotermia à admissão diminuiu significativamente em PII (37,2 x14,2%, p < 0,0001) e a mediana de temperatura foi mais elevada (36,1x36,5° C, p < 0,001). Houve aumento significativo do número de crianças transportadas com oxigênio em PII (49,5 x 75,5%, p < 0,0001). Não houve diferenças para peso ao nascer e idade gestacional. Conclusão: Houve redução acentuada de hipotermia à admissão e melhora na mediana da temperatura de admissão hospitalar em recém-nascidos pré-termo de muito baixo peso após implantação do protocolo. Keywords: Hypothermia, Very low birth weight infant, Quality of health care, Palavras-chave: Hipotermia, Recém-nascido de muito baixo peso, Qualidade da assistência à saúdehttp://www.sciencedirect.com/science/article/pii/S0021755717303078
spellingShingle Jamil Pedro de Siqueira Caldas
Fernanda de Castro Millen
Juliana Fernandes de Camargo
Paula Almeida Cavalcanti Castro
Ana Letícia da Fonseca Camilo
Sérgio Tadeu Martins Marba
Effectiveness of a measure program to prevent admission hypothermia in very low-birth weight preterm infants
Jornal de Pediatria
title Effectiveness of a measure program to prevent admission hypothermia in very low-birth weight preterm infants
title_full Effectiveness of a measure program to prevent admission hypothermia in very low-birth weight preterm infants
title_fullStr Effectiveness of a measure program to prevent admission hypothermia in very low-birth weight preterm infants
title_full_unstemmed Effectiveness of a measure program to prevent admission hypothermia in very low-birth weight preterm infants
title_short Effectiveness of a measure program to prevent admission hypothermia in very low-birth weight preterm infants
title_sort effectiveness of a measure program to prevent admission hypothermia in very low birth weight preterm infants
url http://www.sciencedirect.com/science/article/pii/S0021755717303078
work_keys_str_mv AT jamilpedrodesiqueiracaldas effectivenessofameasureprogramtopreventadmissionhypothermiainverylowbirthweightpreterminfants
AT fernandadecastromillen effectivenessofameasureprogramtopreventadmissionhypothermiainverylowbirthweightpreterminfants
AT julianafernandesdecamargo effectivenessofameasureprogramtopreventadmissionhypothermiainverylowbirthweightpreterminfants
AT paulaalmeidacavalcanticastro effectivenessofameasureprogramtopreventadmissionhypothermiainverylowbirthweightpreterminfants
AT analeticiadafonsecacamilo effectivenessofameasureprogramtopreventadmissionhypothermiainverylowbirthweightpreterminfants
AT sergiotadeumartinsmarba effectivenessofameasureprogramtopreventadmissionhypothermiainverylowbirthweightpreterminfants