Correction of rotational distortion for catheter-based en face OCT and OCT angiography
We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the...
Main Authors: | , , , , , , , , |
---|---|
Drugi avtorji: | |
Format: | Article |
Jezik: | en_US |
Izdano: |
Optical Society of America
2015
|
Online dostop: | http://hdl.handle.net/1721.1/100227 https://orcid.org/0000-0002-9724-5164 https://orcid.org/0000-0003-4811-3429 https://orcid.org/0000-0002-2570-0770 https://orcid.org/0000-0003-3237-4034 https://orcid.org/0000-0002-0828-4357 https://orcid.org/0000-0002-2976-6195 |
_version_ | 1826198478573797376 |
---|---|
author | Lee, Hsiang-Chieh Wang, Zhao Liang, Kaicheng Tsai, Tsung-Han Mashimo, Hiroshi Fujimoto, James G. Ahsen, Osman Oguz Giacomelli, Michael Gene Potsaid, Benjamin M. |
author2 | Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science |
author_facet | Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science Lee, Hsiang-Chieh Wang, Zhao Liang, Kaicheng Tsai, Tsung-Han Mashimo, Hiroshi Fujimoto, James G. Ahsen, Osman Oguz Giacomelli, Michael Gene Potsaid, Benjamin M. |
author_sort | Lee, Hsiang-Chieh |
collection | MIT |
description | We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm. |
first_indexed | 2024-09-23T11:05:35Z |
format | Article |
id | mit-1721.1/100227 |
institution | Massachusetts Institute of Technology |
language | en_US |
last_indexed | 2024-09-23T11:05:35Z |
publishDate | 2015 |
publisher | Optical Society of America |
record_format | dspace |
spelling | mit-1721.1/1002272022-09-27T17:06:36Z Correction of rotational distortion for catheter-based en face OCT and OCT angiography Lee, Hsiang-Chieh Wang, Zhao Liang, Kaicheng Tsai, Tsung-Han Mashimo, Hiroshi Fujimoto, James G. Ahsen, Osman Oguz Giacomelli, Michael Gene Potsaid, Benjamin M. Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science Massachusetts Institute of Technology. Research Laboratory of Electronics Ahsen, Osman Oguz Lee, Hsiang-Chieh Giacomelli, Michael Gene Wang, Zhao Liang, Kaicheng Tsai, Tsung-Han Potsaid, Benjamin M. Fujimoto, James G. We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm. National Institutes of Health (U.S.) (R01-EY011289-26) National Institutes of Health (U.S.) (R44-EY022864-01) National Institutes of Health (U.S.) (R01-CA075289-16) National Institutes of Health (U.S.) (R44-CA101067-05) National Institutes of Health (U.S.) (R01-CA178636-02) United States. Air Force Office of Scientific Research (Contract FA9550-10-1-0063) United States. Air Force Office of Scientific Research (Contract FA9550-12-1-0499) 2015-12-14T02:11:20Z 2015-12-14T02:11:20Z 2014-09 2014-09 Article http://purl.org/eprint/type/JournalArticle 0146-9592 1539-4794 http://hdl.handle.net/1721.1/100227 Ahsen, Osman O., Hsiang-Chieh Lee, Michael G. Giacomelli, Zhao Wang, Kaicheng Liang, Tsung-Han Tsai, Benjamin Potsaid, Hiroshi Mashimo, and James G. Fujimoto. “Correction of Rotational Distortion for Catheter-Based En Face OCT and OCT Angiography.” Opt. Lett. 39, no. 20 (2014): 5973. https://orcid.org/0000-0002-9724-5164 https://orcid.org/0000-0003-4811-3429 https://orcid.org/0000-0002-2570-0770 https://orcid.org/0000-0003-3237-4034 https://orcid.org/0000-0002-0828-4357 https://orcid.org/0000-0002-2976-6195 en_US http://dx.doi.org/10.1364/ol.39.005973 Optics Letters Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/ application/pdf Optical Society of America PMC |
spellingShingle | Lee, Hsiang-Chieh Wang, Zhao Liang, Kaicheng Tsai, Tsung-Han Mashimo, Hiroshi Fujimoto, James G. Ahsen, Osman Oguz Giacomelli, Michael Gene Potsaid, Benjamin M. Correction of rotational distortion for catheter-based en face OCT and OCT angiography |
title | Correction of rotational distortion for catheter-based en face OCT and OCT angiography |
title_full | Correction of rotational distortion for catheter-based en face OCT and OCT angiography |
title_fullStr | Correction of rotational distortion for catheter-based en face OCT and OCT angiography |
title_full_unstemmed | Correction of rotational distortion for catheter-based en face OCT and OCT angiography |
title_short | Correction of rotational distortion for catheter-based en face OCT and OCT angiography |
title_sort | correction of rotational distortion for catheter based en face oct and oct angiography |
url | http://hdl.handle.net/1721.1/100227 https://orcid.org/0000-0002-9724-5164 https://orcid.org/0000-0003-4811-3429 https://orcid.org/0000-0002-2570-0770 https://orcid.org/0000-0003-3237-4034 https://orcid.org/0000-0002-0828-4357 https://orcid.org/0000-0002-2976-6195 |
work_keys_str_mv | AT leehsiangchieh correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography AT wangzhao correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography AT liangkaicheng correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography AT tsaitsunghan correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography AT mashimohiroshi correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography AT fujimotojamesg correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography AT ahsenosmanoguz correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography AT giacomellimichaelgene correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography AT potsaidbenjaminm correctionofrotationaldistortionforcatheterbasedenfaceoctandoctangiography |