Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units

Thesis: S.M., Massachusetts Institute of Technology, Department of Aeronautics and Astronautics, 2017.

Bibliographic Details
Main Author: McGrath, Timothy M. (Timothy Michael)
Other Authors: Leia Stirling.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2017
Subjects:
Online Access:http://hdl.handle.net/1721.1/112472
_version_ 1826207580447309824
author McGrath, Timothy M. (Timothy Michael)
author2 Leia Stirling.
author_facet Leia Stirling.
McGrath, Timothy M. (Timothy Michael)
author_sort McGrath, Timothy M. (Timothy Michael)
collection MIT
description Thesis: S.M., Massachusetts Institute of Technology, Department of Aeronautics and Astronautics, 2017.
first_indexed 2024-09-23T13:51:46Z
format Thesis
id mit-1721.1/112472
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T13:51:46Z
publishDate 2017
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/1124722019-04-10T15:55:39Z Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units McGrath, Timothy M. (Timothy Michael) Leia Stirling. Massachusetts Institute of Technology. Department of Aeronautics and Astronautics. Massachusetts Institute of Technology. Department of Aeronautics and Astronautics. Aeronautics and Astronautics. Thesis: S.M., Massachusetts Institute of Technology, Department of Aeronautics and Astronautics, 2017. Cataloged from PDF version of thesis. Includes bibliographical references (pages 166-170). Current human motion measurement systems using inertial measurement units (IMUs) typically rely on precise alignment, static calibration poses, or dynamic calibration motions. Muller et al. recently proposed a method for online calibration of the human elbow anatomical joint axes via decomposition of angular velocity measurements. This thesis evaluated this calibration-free method in the context of two motion types. First, the method is evaluated with human-generated motions common to occupational rehabilitation, to investigate activities of daily living (ADLs) as online calibration motions. Second, the method is evaluated with parameterized sinusoidal motion, to investigate amplitudes and frequencies of motions that yield robust axis estimations. It was found for the axis of interest, high on-axis motion and low off-axis motion lead to precise axis estimation and high accuracy estimation of the pronation/supination elbow axis. Further, high off-axis motion and low on-axis motion yielded imprecise axis estimation and inaccurate estimation of both the flexion/extension and pronation/supination elbow axes. A comparative study of different filtering methodologies to the estimation of upper extremity human motion was also performed. Compared to a motion capture truth, the Extended Kalman Filter (EKF) and Unscented Kalman Filter (UKF) were found to perform similarly. An implemented particle filter (PF) was found to perform better than both the EKF and UKF, and on the order of accuracy of a manufacturers black-box algorithm. This work is the first to evaluate a particle filter in the estimation of human motion by inertial sensors. The particle filter was then subject to a sensitivity analysis of the error of its estimated 3D orientation to its underlying algorithm inputs, namely, the accelerometer and magnetometer uncertainties, and number of particles. Recommended operational levels for these parameters are reported. Future work will combine the Muller auto-calibration method, robust IMU orientation filters, and knowledge of appropriate online motions to develop an IMU bias correction method for long periods of measurement. by Timothy M. McGrath. S.M. 2017-12-05T19:14:20Z 2017-12-05T19:14:20Z 2017 2017 Thesis http://hdl.handle.net/1721.1/112472 1011355102 eng MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582 170 pages application/pdf Massachusetts Institute of Technology
spellingShingle Aeronautics and Astronautics.
McGrath, Timothy M. (Timothy Michael)
Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units
title Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units
title_full Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units
title_fullStr Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units
title_full_unstemmed Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units
title_short Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units
title_sort influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units
topic Aeronautics and Astronautics.
url http://hdl.handle.net/1721.1/112472
work_keys_str_mv AT mcgrathtimothymtimothymichael influenceofmotionprofileonestimatinganatomicalelbowjointaxesusinginertialmeasurementunits