Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology

Tendons transmit load from muscle to bone by utilizing their unique static and viscoelastic tensile properties. These properties are highly dependent on the composition and structure of the tissue matrix, including the collagen I hierarchy, proteoglycans, and water. While the role of matrix constitu...

Cur síos iomlán

Sonraí bibleagrafaíochta
Príomhchruthaitheoirí: Connizzo, Brianne K, Grodzinsky, Alan J
Rannpháirtithe: Massachusetts Institute of Technology. Center for Biomedical Engineering
Formáid: Alt
Foilsithe / Cruthaithe: Elsevier BV 2018
Rochtain ar líne:http://hdl.handle.net/1721.1/117737
https://orcid.org/0000-0002-4942-3456
_version_ 1826201261516521472
author Connizzo, Brianne K
Grodzinsky, Alan J
author2 Massachusetts Institute of Technology. Center for Biomedical Engineering
author_facet Massachusetts Institute of Technology. Center for Biomedical Engineering
Connizzo, Brianne K
Grodzinsky, Alan J
author_sort Connizzo, Brianne K
collection MIT
description Tendons transmit load from muscle to bone by utilizing their unique static and viscoelastic tensile properties. These properties are highly dependent on the composition and structure of the tissue matrix, including the collagen I hierarchy, proteoglycans, and water. While the role of matrix constituents in the tensile response has been studied, their role in compression, particularly in matrix pressurization via regulation of fluid flow, is not well understood. Injured or diseased tendons and tendon regions that naturally experience compression are known to have alterations in glycosaminoglycan content, which could modulate fluid flow and ultimately mechanical function. While recent theoretical studies have predicted tendon mechanics using poroelastic theory, no experimental data have directly demonstrated such behavior. In this study, we use high-bandwidth AFM-based rheology to determine the dynamic response of tendons to compressive loading at the nanoscale and to determine the presence of poroelastic behavior. Tendons are found to have significant characteristic dynamic relaxation behavior occurring at both low and high frequencies. Classic poroelastic behavior is observed, although we hypothesize that the full dynamic response is caused by a combination of flow-dependent poroelasticity as well as flow-independent viscoelasticity. Tendons also demonstrate regional dependence in their dynamic response, particularly near the junction of tendon and bone, suggesting that the structural and compositional heterogeneity in tendon may be responsible for regional poroelastic behavior. Overall, these experiments provide the foundation for understanding fluid-flow-dependent poroelastic mechanics of tendon, and the methodology is valuable for assessing changes in tendon matrix compressive behavior at the nanoscale. Keywords: Poroelasticity; Viscoelasticity; Tendon; AFM; Nanomechanics
first_indexed 2024-09-23T11:48:52Z
format Article
id mit-1721.1/117737
institution Massachusetts Institute of Technology
last_indexed 2024-09-23T11:48:52Z
publishDate 2018
publisher Elsevier BV
record_format dspace
spelling mit-1721.1/1177372022-09-27T22:06:44Z Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology Connizzo, Brianne K Grodzinsky, Alan J Massachusetts Institute of Technology. Center for Biomedical Engineering Massachusetts Institute of Technology. Department of Biological Engineering Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science Massachusetts Institute of Technology. Department of Mechanical Engineering Connizzo, Brianne K Grodzinsky, Alan J Tendons transmit load from muscle to bone by utilizing their unique static and viscoelastic tensile properties. These properties are highly dependent on the composition and structure of the tissue matrix, including the collagen I hierarchy, proteoglycans, and water. While the role of matrix constituents in the tensile response has been studied, their role in compression, particularly in matrix pressurization via regulation of fluid flow, is not well understood. Injured or diseased tendons and tendon regions that naturally experience compression are known to have alterations in glycosaminoglycan content, which could modulate fluid flow and ultimately mechanical function. While recent theoretical studies have predicted tendon mechanics using poroelastic theory, no experimental data have directly demonstrated such behavior. In this study, we use high-bandwidth AFM-based rheology to determine the dynamic response of tendons to compressive loading at the nanoscale and to determine the presence of poroelastic behavior. Tendons are found to have significant characteristic dynamic relaxation behavior occurring at both low and high frequencies. Classic poroelastic behavior is observed, although we hypothesize that the full dynamic response is caused by a combination of flow-dependent poroelasticity as well as flow-independent viscoelasticity. Tendons also demonstrate regional dependence in their dynamic response, particularly near the junction of tendon and bone, suggesting that the structural and compositional heterogeneity in tendon may be responsible for regional poroelastic behavior. Overall, these experiments provide the foundation for understanding fluid-flow-dependent poroelastic mechanics of tendon, and the methodology is valuable for assessing changes in tendon matrix compressive behavior at the nanoscale. Keywords: Poroelasticity; Viscoelasticity; Tendon; AFM; Nanomechanics National Institutes of Health (U.S.) (Grant F32-AG052284) National Science Foundation (U.S.) (Grant CMMI-1536233) 2018-09-13T14:16:06Z 2018-09-13T14:16:06Z 2017-01 2018-09-06T15:58:01Z Article http://purl.org/eprint/type/JournalArticle 0021-9290 http://hdl.handle.net/1721.1/117737 Connizzo, Brianne K., and Alan J. Grodzinsky. “Tendon Exhibits Complex Poroelastic Behavior at the Nanoscale as Revealed by High-Frequency AFM-Based Rheology.” Journal of Biomechanics 54 (March 2017): 11–18 © 2017 Elsevier Ltd https://orcid.org/0000-0002-4942-3456 http://dx.doi.org/10.1016/J.JBIOMECH.2017.01.029 Journal of Biomechanics Creative Commons Attribution-NonCommercial-NoDerivs License http://creativecommons.org/licenses/by-nc-nd/4.0/ application/pdf Elsevier BV PMC
spellingShingle Connizzo, Brianne K
Grodzinsky, Alan J
Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology
title Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology
title_full Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology
title_fullStr Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology
title_full_unstemmed Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology
title_short Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology
title_sort tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high frequency afm based rheology
url http://hdl.handle.net/1721.1/117737
https://orcid.org/0000-0002-4942-3456
work_keys_str_mv AT connizzobriannek tendonexhibitscomplexporoelasticbehavioratthenanoscaleasrevealedbyhighfrequencyafmbasedrheology
AT grodzinskyalanj tendonexhibitscomplexporoelasticbehavioratthenanoscaleasrevealedbyhighfrequencyafmbasedrheology