Characterization of a Condenser for a High Performance Multi-Condenser Loop Heat Pipe

We experimentally characterized a condenser design for a multi-condenser loop heat pipe (LHP) capable of dissipating 1000 W. The LHP is designed for integration into a high performance air-cooled heat sink to address thermal management challenges in advanced electronic systems. The multi-layer stack...

Full description

Bibliographic Details
Main Authors: Hanks, Daniel Frank, Peters, Teresa B., Brisson II, John G, Wang, Evelyn
Other Authors: Massachusetts Institute of Technology. Department of Earth, Atmospheric, and Planetary Sciences
Format: Article
Published: ASME International 2018
Online Access:http://hdl.handle.net/1721.1/119174
https://orcid.org/0000-0002-8974-756X
https://orcid.org/0000-0003-2473-9494
https://orcid.org/0000-0001-7045-1200
Description
Summary:We experimentally characterized a condenser design for a multi-condenser loop heat pipe (LHP) capable of dissipating 1000 W. The LHP is designed for integration into a high performance air-cooled heat sink to address thermal management challenges in advanced electronic systems. The multi-layer stack of condensers utilizes a sintered wick design to stabilize the liquid-vapor interface and prevent liquid flooding of the lower condenser layers in the presence of a gravitational head. In addition a liquid subcooler is incorporated to suppress vapor flashing in the liquid return line. We fabricated the condensers using photo-chemically etched Monel frames with Monel sintered wicks with particle sizes up to 44 νm. We characterized the performance of the condensers in a custom experimental flow rig that monitors the pressure and temperatures of the vapor and liquid. The condenser dissipated the required heat load with a subcooling of up to 18°C, while maintaining a stable liquid-vapor interface with a capillary pressure of 6.2 kPa. In the future, we will incorporate the condenser into a loop heat pipe for a high performance air-cooled heat sink.