Development of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence

This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.

Bibliographic Details
Main Author: Vavrek, Jayson Robert.
Other Authors: Areg Danagoulian and R. Scott Kemp.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2020
Subjects:
Online Access:https://hdl.handle.net/1721.1/123367
_version_ 1811094442404216832
author Vavrek, Jayson Robert.
author2 Areg Danagoulian and R. Scott Kemp.
author_facet Areg Danagoulian and R. Scott Kemp.
Vavrek, Jayson Robert.
author_sort Vavrek, Jayson Robert.
collection MIT
description This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
first_indexed 2024-09-23T16:00:08Z
format Thesis
id mit-1721.1/123367
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T16:00:08Z
publishDate 2020
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/1233672020-01-09T03:02:28Z Development of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence Vavrek, Jayson Robert. Areg Danagoulian and R. Scott Kemp. Massachusetts Institute of Technology. Department of Nuclear Science and Engineering. Massachusetts Institute of Technology. Department of Nuclear Science and Engineering Nuclear Science and Engineering. This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections. Thesis: Ph. D., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2019 Cataloged from student-submitted PDF version of thesis. Includes bibliographical references (pages 93-99). Nearly three decades after the end of the Cold War, nuclear arms control remains a pressing global issue. Despite obligations under the Treaty on the Non-Proliferation of Nuclear Weapons (NPT) to make 'good-faith efforts' to disarm their nuclear arsenals, the United States and Russia still maintain thousands of nuclear warheads. Progress towards complete disarmament has been gradual due to a variety of socio-political barriers, but future efforts towards nuclear arms reduction will face an additional technological hurdle: no technology exists to verify that warheads slated for dismantlement are authentic without revealing any sensitive weapons design information in the process. Despite several decades of research, no technology has solved this apparent paradox between information security and confidence in a warhead verification measurement. Recent work by Kemp, Danagoulian, Macdonald, and Vavrek [1] has produced a novel physical cryptographic verification protocol that approaches this treaty verification problem by exploiting the isotope-specific nature of nuclear resonance fluorescence (NRF) measurements to verify the authenticity of a warhead. To protect sensitive information, the NRF signal from the warhead is convolved with that of an encryption foil that contains key warhead isotopes in amounts unknown to the inspector. The convolved spectrum from a candidate warhead is then statistically compared against that from an authenticated template warhead to determine whether the candidate itself is authentic. Since only the final, convolved spectra are observable, and the detailed foil construction is unknown to the inspector, sensitive information about the warhead is encrypted by physics rather than by software or electronics. In this thesis, we performed proof-of-concept NRF warhead verification experiments at the High Voltage Research Laboratory (HVRL) at MIT [2]. Using high-purity germanium (HPGe) detectors, we measured NRF spectra produced by the interrogation of proxy 'genuine' and 'hoax' objects by a 2.52 MeV endpoint bremsstrahlung beam. The observed differences in NRF intensities near 2.2 MeV indicate that the physical cryptographic protocol can distinguish between proxy genuine and hoax objects with high confidence. Extrapolations to thicker warheads and dedicated verification facilities indicate that realistic warhead verification measurements could be made on the order of hours. In support of these and future NRF experiments, we also improved and benchmarked the G4NRF code for the simulation of NRF in Geant4 [3]. We first constructed a high-accuracy semi-analytical model for the expected NRF count rate in both simple homogeneous and more complex heterogeneous geometries. We then performed Geant4+G4NRF simulations with these geometries, and found agreement in NRF rates predicted by the semi-analytical model and observed in the simulation at a level of ~1% in simple test cases and ~3% in the more realistic complex scenarios. These results improve upon the ~20% level of the initial G4NRF benchmarking study and establish a highly-accurate NRF framework for Geant [4]. Finally, we conducted a G4NRF validation study using the NRF data taken during the warhead verification experiments [4]. Agreement between the absolute NRF count rates observed in the data and predicted by extensive Geant4+G4NRF modeling validate the combined Geant4+G4NRF model to within ~20% in the 238U NRF transitions and 9% in 27Al, for an average 14% discrepancy across the entire study. Additionally, agreement between the model and data in relative NRF rates is found at the level of .5%. Such agreement in both relative and absolute analyses provides good predictive capability for the design and analysis of future NRF experiments using G4NRF, whether for warhead verification or other applications. by Jayson Robert Vavrek. Ph. D. Ph.D. Massachusetts Institute of Technology, Department of Nuclear Science and Engineering 2020-01-08T19:35:06Z 2020-01-08T19:35:06Z 2019 2019 Thesis https://hdl.handle.net/1721.1/123367 1134982479 eng MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582 99 pages application/pdf Massachusetts Institute of Technology
spellingShingle Nuclear Science and Engineering.
Vavrek, Jayson Robert.
Development of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence
title Development of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence
title_full Development of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence
title_fullStr Development of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence
title_full_unstemmed Development of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence
title_short Development of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence
title_sort development of an isotope sensitive warhead verification technique using nuclear resonance fluorescence
topic Nuclear Science and Engineering.
url https://hdl.handle.net/1721.1/123367
work_keys_str_mv AT vavrekjaysonrobert developmentofanisotopesensitivewarheadverificationtechniqueusingnuclearresonancefluorescence