Non-contact ultrasound

Thesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2019

Bibliographic Details
Main Author: Zhang, Xiang,Ph. D.Massachusetts Institute of Technology.
Other Authors: Brian W. Anthony.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2020
Subjects:
Online Access:https://hdl.handle.net/1721.1/123779
_version_ 1811068883237339136
author Zhang, Xiang,Ph. D.Massachusetts Institute of Technology.
author2 Brian W. Anthony.
author_facet Brian W. Anthony.
Zhang, Xiang,Ph. D.Massachusetts Institute of Technology.
author_sort Zhang, Xiang,Ph. D.Massachusetts Institute of Technology.
collection MIT
description Thesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2019
first_indexed 2024-09-23T08:02:27Z
format Thesis
id mit-1721.1/123779
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T08:02:27Z
publishDate 2020
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/1237792020-02-11T03:36:47Z Non-contact ultrasound Zhang, Xiang,Ph. D.Massachusetts Institute of Technology. Brian W. Anthony. Massachusetts Institute of Technology. Department of Mechanical Engineering. Massachusetts Institute of Technology. Department of Mechanical Engineering Mechanical Engineering. Thesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2019 Cataloged from PDF version of thesis. Includes bibliographical references (pages 145-157). This thesis explores the design, development, and evaluation of two novel non-contact ultrasound imaging methods: immersion ultrasound and optical ultrasound. Immersion ultrasound utilizes traditional piezoelectric elements in a tomographic framework to develop new algorithms and acquisition methods for quantification of tissue geometry and properties in human proximal limbs. Bone is uniquely challenging for ultrasound due to the high impedance mismatch between bone and soft-tissue in the imaging domain. New imaging algorithms are necessary for both geometric and quantitative reconstruction of subjects with bone. Multiple immersion systems were designed and constructed using the framework presented in this thesis. Mechanical systems include a 4 degrees of freedom single element system and a fully flexible 36 degrees of freedom robotic system abbreviated MEDUSA (Mechanically Discrete Ultrasound Scanning Apparatus). An adaptive beamforming algorithm addressing specularity of bone in pulse-echo imaging and a Full Waveform Inversion algorithm for quantitative imaging with bone are discussed, with imaging results on tissue mimicking phantoms, excised animal tissue, and human subjects. Furthermore, a laser ultrasound (LUS) system was developed for full non-contact ultrasound imaging. LUS completely replaces conventional piezoelectric elements for generation and detection of ultrasound in biological tissue. LUS generates ultrasonic waves at the tissue surface via rapid transduction of optical energy to acoustic energy through thermomechanical coupling on the tissue surface and detects returning ultrasonic waves on the tissue surface using laser interferometry. In combination, LUS can utilize any tissue surface as a viable acoustic transmitter or detector. Analysis of light and tissue interactions presented in this thesis identifies the critical process parameters for soft-tissue imaging at eye and skin safe optical exposure levels. LUS system design methods and imaging results on tissue mimicking phantoms, excised tissue, and humans subjects are presented. Human LUS results marks the first instance of full non-contact optical ultrasound imaging of in-vivo human subjects. All systems presented in this thesis were calibrated to ensure safe optical and acoustic exposure levels for human subjects. Approval was obtained from the MIT Committee on the Use of Humans as Experimental Subjects (COUHES) prior to any human experimentation. by Xiang Zhang. Ph. D. Ph.D. Massachusetts Institute of Technology, Department of Mechanical Engineering 2020-02-10T21:44:34Z 2020-02-10T21:44:34Z 2019 2019 Thesis https://hdl.handle.net/1721.1/123779 1139520545 eng MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582 157 pages application/pdf Massachusetts Institute of Technology
spellingShingle Mechanical Engineering.
Zhang, Xiang,Ph. D.Massachusetts Institute of Technology.
Non-contact ultrasound
title Non-contact ultrasound
title_full Non-contact ultrasound
title_fullStr Non-contact ultrasound
title_full_unstemmed Non-contact ultrasound
title_short Non-contact ultrasound
title_sort non contact ultrasound
topic Mechanical Engineering.
url https://hdl.handle.net/1721.1/123779
work_keys_str_mv AT zhangxiangphdmassachusettsinstituteoftechnology noncontactultrasound