Intercomparison measurements of two 33 S-enriched sulfur isotope standards

Despite widespread applications of sulfur isotope mass-independent fractionation (MIF) signals for probing terrestrial and extra-terrestrial environments, there has been no international sulfur isotope reference material available for normalization of Δ33S and Δ36S data. International reference mate...

Full description

Bibliographic Details
Main Author: Ono, Shuhei
Other Authors: Massachusetts Institute of Technology. Department of Earth, Atmospheric, and Planetary Sciences
Format: Article
Language:English
Published: Royal Society of Chemistry (RSC) 2020
Online Access:https://hdl.handle.net/1721.1/124850
_version_ 1826191606115467264
author Ono, Shuhei
author2 Massachusetts Institute of Technology. Department of Earth, Atmospheric, and Planetary Sciences
author_facet Massachusetts Institute of Technology. Department of Earth, Atmospheric, and Planetary Sciences
Ono, Shuhei
author_sort Ono, Shuhei
collection MIT
description Despite widespread applications of sulfur isotope mass-independent fractionation (MIF) signals for probing terrestrial and extra-terrestrial environments, there has been no international sulfur isotope reference material available for normalization of Δ33S and Δ36S data. International reference materials to anchor isotope values are useful for interlaboratory data comparisons and are needed to evaluate, e.g., whether issues exist associated with blanks and mass spectrometry when using different analytical approaches. We synthesized two sodium sulfate samples enriched in 33S with different magnitudes, and termed them S-MIF-1 and S-MIF-2, respectively. The sulfur isotopic compositions of these two samples were measured in five different laboratories using two distinct techniques to place them on the V-CDT scale for δ34S and a provisional V-CDT scale for Δ33S and Δ36S. We obtained average δ34S values of S-MIF-1 = 10.26 ± 0.22‰ and S-MIF-2 = 21.53 ± 0.26‰ (1σ, versus V-CDT). The average Δ33S and Δ36S values of S-MIF-1 were determined to be 9.54 ± 0.09‰ and -0.11 ± 0.25‰, respectively, while the average Δ33S and Δ36S values of S-MIF-2 are 11.39 ± 0.08‰ and -0.33 ± 0.13‰ (1σ, versus V-CDT). The lack of variation among the interlaboratory isotopic values suggests sufficient homogeneity of S-MIF-1 and S-MIF-2, especially for Δ33S. Although additional measurements may be needed to ensure the accuracy of the isotopic compositions of S-MIF-1 and S-MIF-2, they can serve as working standards for routine Δ33S analysis to improve data consistency, and have the potential to serve as secondary sulfur isotope reference materials to address issues such as scale contraction/expansion and for normalization and reporting of Δ33S and Δ36S between laboratories. For the same reasons as listed for sulfur isotopes, the same standards were also artificially enriched in 17O. The calibration is still in progress but first estimations gave Δ17O = 3.3 ± 0.3‰ with unassigned δ18O. ©2019
first_indexed 2024-09-23T08:58:31Z
format Article
id mit-1721.1/124850
institution Massachusetts Institute of Technology
language English
last_indexed 2024-09-23T08:58:31Z
publishDate 2020
publisher Royal Society of Chemistry (RSC)
record_format dspace
spelling mit-1721.1/1248502022-09-30T12:33:47Z Intercomparison measurements of two 33 S-enriched sulfur isotope standards Ono, Shuhei Massachusetts Institute of Technology. Department of Earth, Atmospheric, and Planetary Sciences Despite widespread applications of sulfur isotope mass-independent fractionation (MIF) signals for probing terrestrial and extra-terrestrial environments, there has been no international sulfur isotope reference material available for normalization of Δ33S and Δ36S data. International reference materials to anchor isotope values are useful for interlaboratory data comparisons and are needed to evaluate, e.g., whether issues exist associated with blanks and mass spectrometry when using different analytical approaches. We synthesized two sodium sulfate samples enriched in 33S with different magnitudes, and termed them S-MIF-1 and S-MIF-2, respectively. The sulfur isotopic compositions of these two samples were measured in five different laboratories using two distinct techniques to place them on the V-CDT scale for δ34S and a provisional V-CDT scale for Δ33S and Δ36S. We obtained average δ34S values of S-MIF-1 = 10.26 ± 0.22‰ and S-MIF-2 = 21.53 ± 0.26‰ (1σ, versus V-CDT). The average Δ33S and Δ36S values of S-MIF-1 were determined to be 9.54 ± 0.09‰ and -0.11 ± 0.25‰, respectively, while the average Δ33S and Δ36S values of S-MIF-2 are 11.39 ± 0.08‰ and -0.33 ± 0.13‰ (1σ, versus V-CDT). The lack of variation among the interlaboratory isotopic values suggests sufficient homogeneity of S-MIF-1 and S-MIF-2, especially for Δ33S. Although additional measurements may be needed to ensure the accuracy of the isotopic compositions of S-MIF-1 and S-MIF-2, they can serve as working standards for routine Δ33S analysis to improve data consistency, and have the potential to serve as secondary sulfur isotope reference materials to address issues such as scale contraction/expansion and for normalization and reporting of Δ33S and Δ36S between laboratories. For the same reasons as listed for sulfur isotopes, the same standards were also artificially enriched in 17O. The calibration is still in progress but first estimations gave Δ17O = 3.3 ± 0.3‰ with unassigned δ18O. ©2019 2020-04-24T15:10:14Z 2020-04-24T15:10:14Z 2019-03 2019-01 2020-04-06T19:38:11Z Article http://purl.org/eprint/type/JournalArticle 0267-9477 1364-5544 https://hdl.handle.net/1721.1/124850 Gen, L., et al., "Intercomparison measurements of two 33 S-enriched sulfur isotope standards." Journal of analytical atomic spectrometry 34, 6 (Mar. 2019): no. 1263 doi 10.1039/C8JA00451J ©2019 Author(s) en 10.1039/C8JA00451J Journal of analytical atomic spectrometry Creative Commons Attribution 3.0 unported license https://creativecommons.org/licenses/by/3.0/ application/pdf Royal Society of Chemistry (RSC) Royal Society of Chemistry (RSC)
spellingShingle Ono, Shuhei
Intercomparison measurements of two 33 S-enriched sulfur isotope standards
title Intercomparison measurements of two 33 S-enriched sulfur isotope standards
title_full Intercomparison measurements of two 33 S-enriched sulfur isotope standards
title_fullStr Intercomparison measurements of two 33 S-enriched sulfur isotope standards
title_full_unstemmed Intercomparison measurements of two 33 S-enriched sulfur isotope standards
title_short Intercomparison measurements of two 33 S-enriched sulfur isotope standards
title_sort intercomparison measurements of two 33 s enriched sulfur isotope standards
url https://hdl.handle.net/1721.1/124850
work_keys_str_mv AT onoshuhei intercomparisonmeasurementsoftwo33senrichedsulfurisotopestandards