Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study

Objective: To develop and test a new reusable, sterilisable N95 filtering facepiece respirator (FFR)-comparable face mask, known as the Injection Molded Autoclavable, Scalable, Conformable (iMASC) system, given the dire need for personal protective equipment within healthcare settings during the COV...

Full description

Bibliographic Details
Main Authors: Byrne, James D, Wentworth, Adam J, Chai, Peter R, Huang, Hen Wei, Babaee, Sahab, Li, Canchen, Becker, Sarah L, Tov, Caitlynn, Min, Seokkee, Traverso, Giovanni
Other Authors: Massachusetts Institute of Technology. Department of Mechanical Engineering
Format: Article
Published: BMJ 2020
Online Access:https://hdl.handle.net/1721.1/126121
_version_ 1811096108459360256
author Byrne, James D
Wentworth, Adam J
Chai, Peter R
Huang, Hen Wei
Babaee, Sahab
Li, Canchen
Becker, Sarah L
Tov, Caitlynn
Min, Seokkee
Traverso, Giovanni
author2 Massachusetts Institute of Technology. Department of Mechanical Engineering
author_facet Massachusetts Institute of Technology. Department of Mechanical Engineering
Byrne, James D
Wentworth, Adam J
Chai, Peter R
Huang, Hen Wei
Babaee, Sahab
Li, Canchen
Becker, Sarah L
Tov, Caitlynn
Min, Seokkee
Traverso, Giovanni
author_sort Byrne, James D
collection MIT
description Objective: To develop and test a new reusable, sterilisable N95 filtering facepiece respirator (FFR)-comparable face mask, known as the Injection Molded Autoclavable, Scalable, Conformable (iMASC) system, given the dire need for personal protective equipment within healthcare settings during the COVID-19 pandemic. Design: Single-arm feasibility study. Emergency department and outpatient oncology clinic. Participants: Healthcare workers who have previously undergone N95 fit testing. Fit testing of new iMASC system. Primary and secondary outcome measures: Primary outcome is success of fit testing using an Occupational Safety and Health Administration (OSHA)-approved testing method, and secondary outcomes are user experience with fit, breathability and filter replacement. Results: Twenty-four subjects were recruited to undergo fit testing, and the average age of subjects was 41 years (range of 21–65 years) with an average body mass index of 26.5 kg/m2. The breakdown of participants by profession was 46% nurses (n=11), 21% attending physicians (n=5), 21% resident physicians (n=5) and 12% technicians (n=3). Of these participants, four did not perform the fit testing due to the inability to detect saccharin solution on premask placement sensitivity test, lack of time and inability to place mask over hair. All participants (n=20) who performed the fit test were successfully fitted for the iMASC system using an OSHA-approved testing method. User experience with the iMASC system, as evaluated using a Likert scale with a score of 1 indicating excellent and a score of 5 indicating very poor, demonstrated an average fit score of 1.75, breathability of 1.6, and ease of replacing the filter on the mask was scored on average as 2.05. Conclusions: The iMASC system was shown to successfully fit multiple different face sizes and shapes using an OSHA-approved testing method. These data support further certification testing needed for use in the healthcare setting.
first_indexed 2024-09-23T16:38:23Z
format Article
id mit-1721.1/126121
institution Massachusetts Institute of Technology
last_indexed 2024-09-23T16:38:23Z
publishDate 2020
publisher BMJ
record_format dspace
spelling mit-1721.1/1261212022-09-29T20:30:14Z Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study Byrne, James D Wentworth, Adam J Chai, Peter R Huang, Hen Wei Babaee, Sahab Li, Canchen Becker, Sarah L Tov, Caitlynn Min, Seokkee Traverso, Giovanni Massachusetts Institute of Technology. Department of Mechanical Engineering Koch Institute for Integrative Cancer Research at MIT Objective: To develop and test a new reusable, sterilisable N95 filtering facepiece respirator (FFR)-comparable face mask, known as the Injection Molded Autoclavable, Scalable, Conformable (iMASC) system, given the dire need for personal protective equipment within healthcare settings during the COVID-19 pandemic. Design: Single-arm feasibility study. Emergency department and outpatient oncology clinic. Participants: Healthcare workers who have previously undergone N95 fit testing. Fit testing of new iMASC system. Primary and secondary outcome measures: Primary outcome is success of fit testing using an Occupational Safety and Health Administration (OSHA)-approved testing method, and secondary outcomes are user experience with fit, breathability and filter replacement. Results: Twenty-four subjects were recruited to undergo fit testing, and the average age of subjects was 41 years (range of 21–65 years) with an average body mass index of 26.5 kg/m2. The breakdown of participants by profession was 46% nurses (n=11), 21% attending physicians (n=5), 21% resident physicians (n=5) and 12% technicians (n=3). Of these participants, four did not perform the fit testing due to the inability to detect saccharin solution on premask placement sensitivity test, lack of time and inability to place mask over hair. All participants (n=20) who performed the fit test were successfully fitted for the iMASC system using an OSHA-approved testing method. User experience with the iMASC system, as evaluated using a Likert scale with a score of 1 indicating excellent and a score of 5 indicating very poor, demonstrated an average fit score of 1.75, breathability of 1.6, and ease of replacing the filter on the mask was scored on average as 2.05. Conclusions: The iMASC system was shown to successfully fit multiple different face sizes and shapes using an OSHA-approved testing method. These data support further certification testing needed for use in the healthcare setting. 2020-07-10T14:09:07Z 2020-07-10T14:09:07Z 2020-07 2020-06 Article http://purl.org/eprint/type/JournalArticle 2044-6055 2044-6055 https://hdl.handle.net/1721.1/126121 Byrne, James D. et al. "Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study." BMJ Open 10, 7 (July 2020): e039120 © Author(s) http://dx.doi.org/10.1136/bmjopen-2020-039120 BMJ Open Creative Commons Attribution NonCommercial License 4.0 https://creativecommons.org/licenses/by-nc/4.0/ application/pdf BMJ BMJ Open
spellingShingle Byrne, James D
Wentworth, Adam J
Chai, Peter R
Huang, Hen Wei
Babaee, Sahab
Li, Canchen
Becker, Sarah L
Tov, Caitlynn
Min, Seokkee
Traverso, Giovanni
Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study
title Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study
title_full Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study
title_fullStr Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study
title_full_unstemmed Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study
title_short Injection Molded Autoclavable, Scalable, Conformable (iMASC) system for aerosol-based protection: a prospective single-arm feasibility study
title_sort injection molded autoclavable scalable conformable imasc system for aerosol based protection a prospective single arm feasibility study
url https://hdl.handle.net/1721.1/126121
work_keys_str_mv AT byrnejamesd injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT wentworthadamj injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT chaipeterr injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT huanghenwei injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT babaeesahab injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT licanchen injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT beckersarahl injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT tovcaitlynn injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT minseokkee injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy
AT traversogiovanni injectionmoldedautoclavablescalableconformableimascsystemforaerosolbasedprotectionaprospectivesinglearmfeasibilitystudy