Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile

Background Glaucoma is the leading cause of irreversible blindness worldwide. It is a heterogeneous group of conditions with a common optic neuropathy and associated loss of peripheral vision. Both over and under-diagnosis carry high costs in terms of healthcare spending and preventable blindness. T...

Full description

Bibliographic Details
Main Author: Brown, Emery Neal
Other Authors: Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2020
Online Access:https://hdl.handle.net/1721.1/126702
_version_ 1826213941349449728
author Brown, Emery Neal
author2 Massachusetts Institute of Technology. Institute for Medical Engineering & Science
author_facet Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Brown, Emery Neal
author_sort Brown, Emery Neal
collection MIT
description Background Glaucoma is the leading cause of irreversible blindness worldwide. It is a heterogeneous group of conditions with a common optic neuropathy and associated loss of peripheral vision. Both over and under-diagnosis carry high costs in terms of healthcare spending and preventable blindness. The characteristic clinical feature of glaucoma is asymmetrical optic nerve rim narrowing, which is difficult for humans to quantify reliably. Strategies to improve and automate optic disc assessment are therefore needed to prevent sight loss. Methods We developed a novel glaucoma detection algorithm that segments and analyses colour photographs to quantify optic nerve rim consistency around the whole disc at 15-degree intervals. This provides a profile of the cup/disc ratio, in contrast to the vertical cup/disc ratio in common use. We introduce a spatial probabilistic model, to account for the optic nerve shape, we then use this model to derive a disc deformation index and a decision rule for glaucoma. We tested our algorithm on two separate image datasets (ORIGA and RIM-ONE). Results The spatial algorithm accurately distinguished glaucomatous and healthy discs on internal and external validation (AUROC 99.6% and 91.0% respectively). It achieves this using a dataset 100-times smaller than that required for deep learning algorithms, is flexible to the type of cup and disc segmentation (automated or semi-automated), utilises images with missing data, and is correlated with the disc size (p = 0.02) and the rim-to-disc at the narrowest rim (p<0.001, in external validation). Discussion The spatial probabilistic algorithm is highly accurate, highly data efficient and it extends to any imaging hardware in which the boundaries of cup and disc can be segmented, thus making the algorithm particularly applicable to research into disease mechanisms, and also glaucoma screening in low resource settings.
first_indexed 2024-09-23T15:57:16Z
format Article
id mit-1721.1/126702
institution Massachusetts Institute of Technology
language English
last_indexed 2024-09-23T15:57:16Z
publishDate 2020
publisher Public Library of Science (PLoS)
record_format dspace
spelling mit-1721.1/1267022022-09-29T17:16:39Z Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile Brown, Emery Neal Massachusetts Institute of Technology. Institute for Medical Engineering & Science Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences Background Glaucoma is the leading cause of irreversible blindness worldwide. It is a heterogeneous group of conditions with a common optic neuropathy and associated loss of peripheral vision. Both over and under-diagnosis carry high costs in terms of healthcare spending and preventable blindness. The characteristic clinical feature of glaucoma is asymmetrical optic nerve rim narrowing, which is difficult for humans to quantify reliably. Strategies to improve and automate optic disc assessment are therefore needed to prevent sight loss. Methods We developed a novel glaucoma detection algorithm that segments and analyses colour photographs to quantify optic nerve rim consistency around the whole disc at 15-degree intervals. This provides a profile of the cup/disc ratio, in contrast to the vertical cup/disc ratio in common use. We introduce a spatial probabilistic model, to account for the optic nerve shape, we then use this model to derive a disc deformation index and a decision rule for glaucoma. We tested our algorithm on two separate image datasets (ORIGA and RIM-ONE). Results The spatial algorithm accurately distinguished glaucomatous and healthy discs on internal and external validation (AUROC 99.6% and 91.0% respectively). It achieves this using a dataset 100-times smaller than that required for deep learning algorithms, is flexible to the type of cup and disc segmentation (automated or semi-automated), utilises images with missing data, and is correlated with the disc size (p = 0.02) and the rim-to-disc at the narrowest rim (p<0.001, in external validation). Discussion The spatial probabilistic algorithm is highly accurate, highly data efficient and it extends to any imaging hardware in which the boundaries of cup and disc can be segmented, thus making the algorithm particularly applicable to research into disease mechanisms, and also glaucoma screening in low resource settings. 2020-08-20T13:53:14Z 2020-08-20T13:53:14Z 2019-01 2018-08 2019-09-30T15:51:06Z Article http://purl.org/eprint/type/JournalArticle 1932-6203 https://hdl.handle.net/1721.1/126702 MacCormick, Ian J. C. et al. “Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile.” PLoS ONE, vol. 14, no. 1, 2019, e0209409 © 2019 The Author(s) en 10.1371/JOURNAL.PONE.0209409 PLoS ONE Creative Commons Attribution 4.0 International license http://creativecommons.org/licenses/by-nc-nd/4.0/ application/pdf Public Library of Science (PLoS) PLoS
spellingShingle Brown, Emery Neal
Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile
title Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile
title_full Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile
title_fullStr Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile
title_full_unstemmed Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile
title_short Accurate, fast, data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile
title_sort accurate fast data efficient and interpretable glaucoma diagnosis with automated spatial analysis of the whole cup to disc profile
url https://hdl.handle.net/1721.1/126702
work_keys_str_mv AT brownemeryneal accuratefastdataefficientandinterpretableglaucomadiagnosiswithautomatedspatialanalysisofthewholecuptodiscprofile