System identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography

Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, May, 2020

Bibliographic Details
Main Author: Chavez, Yasmin.
Other Authors: Brian W. Anthony.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2020
Subjects:
Online Access:https://hdl.handle.net/1721.1/127155
_version_ 1811096792122523648
author Chavez, Yasmin.
author2 Brian W. Anthony.
author_facet Brian W. Anthony.
Chavez, Yasmin.
author_sort Chavez, Yasmin.
collection MIT
description Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, May, 2020
first_indexed 2024-09-23T16:49:04Z
format Thesis
id mit-1721.1/127155
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T16:49:04Z
publishDate 2020
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/1271552020-09-04T03:01:28Z System identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography Chavez, Yasmin. Brian W. Anthony. Massachusetts Institute of Technology. Department of Mechanical Engineering. Massachusetts Institute of Technology. Department of Mechanical Engineering Mechanical Engineering. Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, May, 2020 Cataloged from the official PDF of thesis. Includes bibliographical references (pages 65-66). An acoustic radiation force (ARF) is commonly used to generate shear waves in ultrasound systems for shear wave elastography (SWE). However, ARF requires complex hardware that produces thermal stresses in tissues and electronic components. External mechanical vibration (EMV) is less power-exhaustive compared to ARF. Additionally, EMV-based shear waves have been shown to produce larger, local displacements in comparison to ARF-based shear waves which is beneficial for imaging deeper tissues. EMV provides the opportunity for the development of a low-cost, compact, and efficient alternative to ARF-based SWE systems. A miniature EMV SWE system consisting of up to two vibrating voice coil actuators (VCAs) attached to a commercial ultrasound probe was previously designed and developed. The vibration of the VCAs was synchronized with the commercial ultrasound system to induce shear waves, replacing the ARF. Preliminary testing on this system has shown the system's ability to produce results comparable to ARF-based SWE. In this work, the miniature EMV SWE system is further developed. The VCA is replaced with another that has an integrated position sensor. This eliminates complex external sensing circuitry. The circuitry is simplified and placed on a PCB, further decreasing the footprint of the system while increasing the robustness of the electronic connections. The system is modeled and experimental data is collected to validate the model. Data is collected using a frequency sweep to obtain the magnitude and phase of the signals of interest. A lead controller is designed to perform position control on the VCA, and its performance is evaluated. The bode plot of the system model is found to have no phase margin at the crossover frequency, therefore a lead controller is designed to provide a phase boost. The controller successfully provides a phase boost. However, the experiments reveal the difference between theoretical models and physically feasible results. The VCA exhibits non-linear behavior at low frequencies possibly due to friction. The VCA also has a maximum vibration frequency between 80-90 Hz. The phase margin increases as intended before this limit but rapidly declines as the system approaches this limit. Further exploration into the VCA is necessary, and additional studies are needed to validate the system's efficacy on phantoms, ex-vivo tissues, and in-vivo tissues. by Yasmin Chavez. S.M. S.M. Massachusetts Institute of Technology, Department of Mechanical Engineering 2020-09-03T17:49:47Z 2020-09-03T17:49:47Z 2020 2020 Thesis https://hdl.handle.net/1721.1/127155 1191840961 eng MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided. http://dspace.mit.edu/handle/1721.1/7582 66 pages application/pdf Massachusetts Institute of Technology
spellingShingle Mechanical Engineering.
Chavez, Yasmin.
System identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography
title System identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography
title_full System identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography
title_fullStr System identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography
title_full_unstemmed System identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography
title_short System identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography
title_sort system identification and control of a miniature external mechanical vibration device towards clinical ultrasound shear wave elastography
topic Mechanical Engineering.
url https://hdl.handle.net/1721.1/127155
work_keys_str_mv AT chavezyasmin systemidentificationandcontrolofaminiatureexternalmechanicalvibrationdevicetowardsclinicalultrasoundshearwaveelastography