Abstract Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present work, organ and effective dose coefficients hav...

Full description

Bibliographic Details
Main Authors: Bales, K., Dewji, S., Sanchez, E.
Other Authors: Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Format: Article
Language:English
Published: Springer Berlin Heidelberg 2021
Online Access:https://hdl.handle.net/1721.1/131409
_version_ 1826200454002900992
author Bales, K.
Dewji, S.
Sanchez, E.
author2 Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
author_facet Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Bales, K.
Dewji, S.
Sanchez, E.
author_sort Bales, K.
collection MIT
description Abstract Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present work, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory’s articulated stylized adult phantom, “Phantom wIth Moving Arms and Legs” (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10− 9 to 20 MeV for the ICRP Publication 116 external exposure geometries—antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses.
first_indexed 2024-09-23T11:36:43Z
format Article
id mit-1721.1/131409
institution Massachusetts Institute of Technology
language English
last_indexed 2024-09-23T11:36:43Z
publishDate 2021
publisher Springer Berlin Heidelberg
record_format dspace
spelling mit-1721.1/1314092023-09-27T20:43:11Z Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries Bales, K. Dewji, S. Sanchez, E. Massachusetts Institute of Technology. Department of Nuclear Science and Engineering Abstract Neutron dose coefficients for standard irradiation geometries have been reported in International Commission on Radiological Protection (ICRP) Publication 116 for the ICRP Publication 110 adult reference phantoms. In the present work, organ and effective dose coefficients have been calculated for a receptor in both upright and articulated (bent) postures representing more realistic working postures exposed to a mono-energetic neutron radiation field. This work builds upon prior work by Dewji and co-workers comparing upright and bent postures for exposure to mono-energetic photon fields. Simulations were conducted using the Oak Ridge National Laboratory’s articulated stylized adult phantom, “Phantom wIth Moving Arms and Legs” (PIMAL) software package, and the Monte Carlo N-Particle (MCNP) version 6.1.1 radiation transport code. Organ doses were compared for the upright and bent (45° and 90°) phantom postures for neutron energies ranging from 1 × 10− 9 to 20 MeV for the ICRP Publication 116 external exposure geometries—antero-posterior (AP), postero-anterior (PA), and left and right lateral (LLAT, RLAT). Using both male and female phantoms, effective dose coefficients were computed using ICRP Publication 103 methodology. The resulting coefficients for articulated phantoms were compared to those of the upright phantom. Computed organ and effective dose coefficients are discussed as a function of neutron energy, phantom posture, and source irradiation geometry. For example, it is shown here that for the AP and PA irradiation geometries, the differences in the organ coefficients between the upright and bent posture become more pronounced with increasing bending angle. In the AP geometry, the brain dose coefficients are expectedly higher in the bent postures than in the upright posture, while all other organs have lower dose coefficients, with the thyroid showing the greatest difference. Overall, the effective dose estimated for the upright phantom is more conservative than that for the articulated phantom, which may have ramifications in the estimation or reconstruction of radiation doses. 2021-09-20T17:16:57Z 2021-09-20T17:16:57Z 2018-08-23 2020-09-24T20:56:57Z Article http://purl.org/eprint/type/JournalArticle https://hdl.handle.net/1721.1/131409 en https://doi.org/10.1007/s00411-018-0751-8 Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply application/pdf Springer Berlin Heidelberg Springer Berlin Heidelberg
spellingShingle Bales, K.
Dewji, S.
Sanchez, E.
Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries
title Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries
title_full Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries
title_fullStr Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries
title_full_unstemmed Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries
title_short Comparison of neutron organ and effective dose coefficients for PIMAL stylized phantom in bent postures in standard irradiation geometries
title_sort comparison of neutron organ and effective dose coefficients for pimal stylized phantom in bent postures in standard irradiation geometries
url https://hdl.handle.net/1721.1/131409
work_keys_str_mv AT balesk comparisonofneutronorganandeffectivedosecoefficientsforpimalstylizedphantominbentposturesinstandardirradiationgeometries
AT dewjis comparisonofneutronorganandeffectivedosecoefficientsforpimalstylizedphantominbentposturesinstandardirradiationgeometries
AT sancheze comparisonofneutronorganandeffectivedosecoefficientsforpimalstylizedphantominbentposturesinstandardirradiationgeometries