Laser calibration system for time of flight scintillator arrays

© 2020 Elsevier B.V. A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commis...

Full description

Bibliographic Details
Main Authors: Denniston, A, Segarra, EP, Olivenboim, M, Nambrath, A, Schmidt, A, Beck, A, Cruz-Torres, R, Hauenstein, F, Hrnjic, A, Kutz, T, May-Tal Beck, S, Pybus, JR, Toledo, P, Hen, O, Weinstein, LB, Piasetzky, E, Korover, I
Format: Article
Language:English
Published: Elsevier BV 2021
Online Access:https://hdl.handle.net/1721.1/132466
_version_ 1826211376600711168
author Denniston, A
Segarra, EP
Olivenboim, M
Nambrath, A
Schmidt, A
Beck, A
Cruz-Torres, R
Hauenstein, F
Hrnjic, A
Kutz, T
May-Tal Beck, S
Pybus, JR
Toledo, P
Hen, O
Weinstein, LB
Piasetzky, E
Korover, I
author_facet Denniston, A
Segarra, EP
Olivenboim, M
Nambrath, A
Schmidt, A
Beck, A
Cruz-Torres, R
Hauenstein, F
Hrnjic, A
Kutz, T
May-Tal Beck, S
Pybus, JR
Toledo, P
Hen, O
Weinstein, LB
Piasetzky, E
Korover, I
author_sort Denniston, A
collection MIT
description © 2020 Elsevier B.V. A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors.
first_indexed 2024-09-23T15:04:55Z
format Article
id mit-1721.1/132466
institution Massachusetts Institute of Technology
language English
last_indexed 2024-09-23T15:04:55Z
publishDate 2021
publisher Elsevier BV
record_format dspace
spelling mit-1721.1/1324662021-09-21T03:14:45Z Laser calibration system for time of flight scintillator arrays Denniston, A Segarra, EP Olivenboim, M Nambrath, A Schmidt, A Beck, A Cruz-Torres, R Hauenstein, F Hrnjic, A Kutz, T May-Tal Beck, S Pybus, JR Toledo, P Hen, O Weinstein, LB Piasetzky, E Korover, I © 2020 Elsevier B.V. A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors. 2021-09-20T18:22:33Z 2021-09-20T18:22:33Z 2020-10-27T17:45:06Z Article http://purl.org/eprint/type/JournalArticle https://hdl.handle.net/1721.1/132466 en 10.1016/j.nima.2020.164177 Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Creative Commons Attribution-NonCommercial-NoDerivs License http://creativecommons.org/licenses/by-nc-nd/4.0/ application/pdf Elsevier BV arXiv
spellingShingle Denniston, A
Segarra, EP
Olivenboim, M
Nambrath, A
Schmidt, A
Beck, A
Cruz-Torres, R
Hauenstein, F
Hrnjic, A
Kutz, T
May-Tal Beck, S
Pybus, JR
Toledo, P
Hen, O
Weinstein, LB
Piasetzky, E
Korover, I
Laser calibration system for time of flight scintillator arrays
title Laser calibration system for time of flight scintillator arrays
title_full Laser calibration system for time of flight scintillator arrays
title_fullStr Laser calibration system for time of flight scintillator arrays
title_full_unstemmed Laser calibration system for time of flight scintillator arrays
title_short Laser calibration system for time of flight scintillator arrays
title_sort laser calibration system for time of flight scintillator arrays
url https://hdl.handle.net/1721.1/132466
work_keys_str_mv AT dennistona lasercalibrationsystemfortimeofflightscintillatorarrays
AT segarraep lasercalibrationsystemfortimeofflightscintillatorarrays
AT olivenboimm lasercalibrationsystemfortimeofflightscintillatorarrays
AT nambratha lasercalibrationsystemfortimeofflightscintillatorarrays
AT schmidta lasercalibrationsystemfortimeofflightscintillatorarrays
AT becka lasercalibrationsystemfortimeofflightscintillatorarrays
AT cruztorresr lasercalibrationsystemfortimeofflightscintillatorarrays
AT hauensteinf lasercalibrationsystemfortimeofflightscintillatorarrays
AT hrnjica lasercalibrationsystemfortimeofflightscintillatorarrays
AT kutzt lasercalibrationsystemfortimeofflightscintillatorarrays
AT maytalbecks lasercalibrationsystemfortimeofflightscintillatorarrays
AT pybusjr lasercalibrationsystemfortimeofflightscintillatorarrays
AT toledop lasercalibrationsystemfortimeofflightscintillatorarrays
AT heno lasercalibrationsystemfortimeofflightscintillatorarrays
AT weinsteinlb lasercalibrationsystemfortimeofflightscintillatorarrays
AT piasetzkye lasercalibrationsystemfortimeofflightscintillatorarrays
AT koroveri lasercalibrationsystemfortimeofflightscintillatorarrays