CUORE-0 detector: design, construction and operation

© 2016 IOP Publishing Ltd and Sissa Medialab srl. The CUORE experiment will search for neutrinoless double-beta decay of 130Te with an array of 988 TeO2 bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Na...

Full description

Bibliographic Details
Format: Article
Language:English
Published: IOP Publishing 2021
Online Access:https://hdl.handle.net/1721.1/133933
_version_ 1826213328001695744
collection MIT
description © 2016 IOP Publishing Ltd and Sissa Medialab srl. The CUORE experiment will search for neutrinoless double-beta decay of 130Te with an array of 988 TeO2 bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
first_indexed 2024-09-23T15:47:19Z
format Article
id mit-1721.1/133933
institution Massachusetts Institute of Technology
language English
last_indexed 2024-09-23T15:47:19Z
publishDate 2021
publisher IOP Publishing
record_format dspace
spelling mit-1721.1/1339332022-04-01T20:12:13Z CUORE-0 detector: design, construction and operation © 2016 IOP Publishing Ltd and Sissa Medialab srl. The CUORE experiment will search for neutrinoless double-beta decay of 130Te with an array of 988 TeO2 bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach. 2021-10-27T19:57:16Z 2021-10-27T19:57:16Z 2016 2019-04-22T16:06:22Z Article http://purl.org/eprint/type/JournalArticle https://hdl.handle.net/1721.1/133933 Alduino, C., et al. "Cuore-0 Detector: Design, Construction and Operation." Journal of Instrumentation 11 7 (2016). en 10.1088/1748-0221/11/07/P07009 Journal of Instrumentation Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/ application/pdf IOP Publishing arXiv
spellingShingle CUORE-0 detector: design, construction and operation
title CUORE-0 detector: design, construction and operation
title_full CUORE-0 detector: design, construction and operation
title_fullStr CUORE-0 detector: design, construction and operation
title_full_unstemmed CUORE-0 detector: design, construction and operation
title_short CUORE-0 detector: design, construction and operation
title_sort cuore 0 detector design construction and operation
url https://hdl.handle.net/1721.1/133933