NILM Dashboard: A Power System Monitor for Electromechanical Equipment Diagnostics
© 2005-2012 IEEE. Nonintrusive load monitoring (NILM) uses electrical measurements taken at a centralized point in a network to monitor many loads downstream. This paper introduces NILM dashboard, a machine intelligence, and graphical platform that uses NILM data for real-time electromechanical syst...
Main Authors: | Aboulian, Andre, Green, Daisy H, Switzer, Jennifer F, Kane, Thomas J, Bredariol, Gregory V, Lindahl, Peter, Donnal, John S, Leeb, Steven B |
---|---|
Other Authors: | Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science |
Format: | Article |
Language: | English |
Published: |
Institute of Electrical and Electronics Engineers (IEEE)
2021
|
Online Access: | https://hdl.handle.net/1721.1/134944 |
Similar Items
-
Shipboard Fault Detection Through Nonintrusive Load Monitoring: A Case Study
by: Lindahl, Peter A, et al.
Published: (2021) -
The NILM Dashboard : watchstanding and real-time fault detection using Non-intrusive Load Monitoring
by: Kane, Thomas John,S.M.Massachusetts Institute of Technology.
Published: (2019) -
Home NILM : a comprehensive energy monitoring toolkit
by: Donnal, John Sebastian
Published: (2013) -
AUV NILM Update
by: Cox, Robert, et al.
Published: (2015) -
Electrical Monitoring of Electromechanical Systems
by: Green, Daisy Hikari
Published: (2022)