Magnetic Cleanliness, Sensing, and Calibration for CubeSats

Magnetometers are widely used on satellites for both attitude sensing and scientific observations. Spaceborne magnetometers have enabled the creation of accurate maps of Earth’s magnetic fields. However, these models have limited spatial and temporal resolution, and therefore are much less accurate...

Full description

Bibliographic Details
Main Author: Belsten, Nicholas
Other Authors: Cahoy, Kerri
Format: Thesis
Published: Massachusetts Institute of Technology 2022
Online Access:https://hdl.handle.net/1721.1/143167
https://orcid.org/0000-0002-5812-8782
_version_ 1826202535734542336
author Belsten, Nicholas
author2 Cahoy, Kerri
author_facet Cahoy, Kerri
Belsten, Nicholas
author_sort Belsten, Nicholas
collection MIT
description Magnetometers are widely used on satellites for both attitude sensing and scientific observations. Spaceborne magnetometers have enabled the creation of accurate maps of Earth’s magnetic fields. However, these models have limited spatial and temporal resolution, and therefore are much less accurate in locations with fast or localized magnetic perturbations. Such perturbations can be particularly problematic near Earth’s poles where field aligned currents come close to the surface of the Earth and are concentrated near satellites in LEO. Science missions which need to know the local magnetic field in the polar regions need to bring their own high-fidelity magnetic sensors. The AERO-VISTA mission comprises a pair of 6U CubeSats which will determine the propagation modes and directions of high frequency (400 kHz–5 MHz) waves in Earth’s ionosphere in the presence of Earth’s aurorae. This mission science requires accurate in-situ magnetic sensing of auroral currents for RF measurement context. This thesis details the design, integration, and testing of the magnetic sensors in the AERO-VISTA Auxiliary Sensor Package (ASP). We discuss the estimation of spacecraft self-interference and implement an informal magnetic interference control process. We present some simple ground testing strategies for magnetic screening of components and measurement of spacecraft self-interference. We evaluate the performance and non-ideal effects of our selected anistropic magnetoresistive (AMR) 3-axis magnetometer. We create a measurement equation, which together with regression techniques, allows for calibration to better than 100 nT repeatability despite non-ideal effects, meeting AERO-VISTA’s requirements. This calibration strategy is extended to include current path and material interference effects. We describe the detailed design of the magnetic sensing system, including the electronics, mechanical design, and software of the ASP. Without self-interference effects, this design has a noise floor better than 10 nTrms.
first_indexed 2024-09-23T12:08:46Z
format Thesis
id mit-1721.1/143167
institution Massachusetts Institute of Technology
last_indexed 2024-09-23T12:08:46Z
publishDate 2022
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/1431672022-06-16T03:31:20Z Magnetic Cleanliness, Sensing, and Calibration for CubeSats Belsten, Nicholas Cahoy, Kerri Massachusetts Institute of Technology. Department of Aeronautics and Astronautics Magnetometers are widely used on satellites for both attitude sensing and scientific observations. Spaceborne magnetometers have enabled the creation of accurate maps of Earth’s magnetic fields. However, these models have limited spatial and temporal resolution, and therefore are much less accurate in locations with fast or localized magnetic perturbations. Such perturbations can be particularly problematic near Earth’s poles where field aligned currents come close to the surface of the Earth and are concentrated near satellites in LEO. Science missions which need to know the local magnetic field in the polar regions need to bring their own high-fidelity magnetic sensors. The AERO-VISTA mission comprises a pair of 6U CubeSats which will determine the propagation modes and directions of high frequency (400 kHz–5 MHz) waves in Earth’s ionosphere in the presence of Earth’s aurorae. This mission science requires accurate in-situ magnetic sensing of auroral currents for RF measurement context. This thesis details the design, integration, and testing of the magnetic sensors in the AERO-VISTA Auxiliary Sensor Package (ASP). We discuss the estimation of spacecraft self-interference and implement an informal magnetic interference control process. We present some simple ground testing strategies for magnetic screening of components and measurement of spacecraft self-interference. We evaluate the performance and non-ideal effects of our selected anistropic magnetoresistive (AMR) 3-axis magnetometer. We create a measurement equation, which together with regression techniques, allows for calibration to better than 100 nT repeatability despite non-ideal effects, meeting AERO-VISTA’s requirements. This calibration strategy is extended to include current path and material interference effects. We describe the detailed design of the magnetic sensing system, including the electronics, mechanical design, and software of the ASP. Without self-interference effects, this design has a noise floor better than 10 nTrms. S.M. 2022-06-15T13:00:52Z 2022-06-15T13:00:52Z 2022-02 2022-02-09T16:09:48.915Z Thesis https://hdl.handle.net/1721.1/143167 https://orcid.org/0000-0002-5812-8782 In Copyright - Educational Use Permitted Copyright MIT http://rightsstatements.org/page/InC-EDU/1.0/ application/pdf Massachusetts Institute of Technology
spellingShingle Belsten, Nicholas
Magnetic Cleanliness, Sensing, and Calibration for CubeSats
title Magnetic Cleanliness, Sensing, and Calibration for CubeSats
title_full Magnetic Cleanliness, Sensing, and Calibration for CubeSats
title_fullStr Magnetic Cleanliness, Sensing, and Calibration for CubeSats
title_full_unstemmed Magnetic Cleanliness, Sensing, and Calibration for CubeSats
title_short Magnetic Cleanliness, Sensing, and Calibration for CubeSats
title_sort magnetic cleanliness sensing and calibration for cubesats
url https://hdl.handle.net/1721.1/143167
https://orcid.org/0000-0002-5812-8782
work_keys_str_mv AT belstennicholas magneticcleanlinesssensingandcalibrationforcubesats