Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial

BACKGROUND: The automated screening of patients at risk of developing diabetic retinopathy represents an opportunity to improve their midterm outcome and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. OBJECTIVE: This stud...

Full description

Bibliographic Details
Main Authors: Noriega, Alejandro, Meizner, Daniela, Camacho, Dalia, Enciso, Jennifer, Quiroz-Mercado, Hugo, Morales-Canton, Virgilio, Almaatouq, Abdullah, Pentland, Alex
Other Authors: Massachusetts Institute of Technology. Media Laboratory
Format: Article
Language:English
Published: JMIR Publications Inc. 2022
Online Access:https://hdl.handle.net/1721.1/144059
_version_ 1826190016845447168
author Noriega, Alejandro
Meizner, Daniela
Camacho, Dalia
Enciso, Jennifer
Quiroz-Mercado, Hugo
Morales-Canton, Virgilio
Almaatouq, Abdullah
Pentland, Alex
author2 Massachusetts Institute of Technology. Media Laboratory
author_facet Massachusetts Institute of Technology. Media Laboratory
Noriega, Alejandro
Meizner, Daniela
Camacho, Dalia
Enciso, Jennifer
Quiroz-Mercado, Hugo
Morales-Canton, Virgilio
Almaatouq, Abdullah
Pentland, Alex
author_sort Noriega, Alejandro
collection MIT
description BACKGROUND: The automated screening of patients at risk of developing diabetic retinopathy represents an opportunity to improve their midterm outcome and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. OBJECTIVE: This study aimed to develop and evaluate the performance of an automated deep learning-based system to classify retinal fundus images as referable and nonreferable diabetic retinopathy cases, from international and Mexican patients. In particular, we aimed to evaluate the performance of the automated retina image analysis (ARIA) system under an independent scheme (ie, only ARIA screening) and 2 assistive schemes (ie, hybrid ARIA plus ophthalmologist screening), using a web-based platform for remote image analysis to determine and compare the sensibility and specificity of the 3 schemes. METHODS: A randomized controlled experiment was performed where 17 ophthalmologists were asked to classify a series of retinal fundus images under 3 different conditions. The conditions were to (1) screen the fundus image by themselves (solo); (2) screen the fundus image after exposure to the retina image classification of the ARIA system (ARIA answer); and (3) screen the fundus image after exposure to the classification of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system (ARIA explanation). The ophthalmologists' classification in each condition and the result from the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of 3 retina specialists for each fundus image. RESULTS: The ARIA system was able to classify referable vs nonreferable cases with an area under the receiver operating characteristic curve of 98%, a sensitivity of 95.1%, and a specificity of 91.5% for international patient cases. There was an area under the receiver operating characteristic curve of 98.3%, a sensitivity of 95.2%, and a specificity of 90% for Mexican patient cases. The ARIA system performance was more successful than the average performance of the 17 ophthalmologists enrolled in the study. Additionally, the results suggest that the ARIA system can be useful as an assistive tool, as sensitivity was significantly higher in the experimental condition where ophthalmologists were exposed to the ARIA system's answer prior to their own classification (93.3%), compared with the sensitivity of the condition where participants assessed the images independently (87.3%; P=.05). CONCLUSIONS: These results demonstrate that both independent and assistive use cases of the ARIA system present, for Latin American countries such as Mexico, a substantial opportunity toward expanding the monitoring capacity for the early detection of diabetes-related blindness.
first_indexed 2024-09-23T08:33:44Z
format Article
id mit-1721.1/144059
institution Massachusetts Institute of Technology
language English
last_indexed 2024-09-23T08:33:44Z
publishDate 2022
publisher JMIR Publications Inc.
record_format dspace
spelling mit-1721.1/1440592023-04-19T19:13:34Z Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial Noriega, Alejandro Meizner, Daniela Camacho, Dalia Enciso, Jennifer Quiroz-Mercado, Hugo Morales-Canton, Virgilio Almaatouq, Abdullah Pentland, Alex Massachusetts Institute of Technology. Media Laboratory BACKGROUND: The automated screening of patients at risk of developing diabetic retinopathy represents an opportunity to improve their midterm outcome and lower the public expenditure associated with direct and indirect costs of common sight-threatening complications of diabetes. OBJECTIVE: This study aimed to develop and evaluate the performance of an automated deep learning-based system to classify retinal fundus images as referable and nonreferable diabetic retinopathy cases, from international and Mexican patients. In particular, we aimed to evaluate the performance of the automated retina image analysis (ARIA) system under an independent scheme (ie, only ARIA screening) and 2 assistive schemes (ie, hybrid ARIA plus ophthalmologist screening), using a web-based platform for remote image analysis to determine and compare the sensibility and specificity of the 3 schemes. METHODS: A randomized controlled experiment was performed where 17 ophthalmologists were asked to classify a series of retinal fundus images under 3 different conditions. The conditions were to (1) screen the fundus image by themselves (solo); (2) screen the fundus image after exposure to the retina image classification of the ARIA system (ARIA answer); and (3) screen the fundus image after exposure to the classification of the ARIA system, as well as its level of confidence and an attention map highlighting the most important areas of interest in the image according to the ARIA system (ARIA explanation). The ophthalmologists' classification in each condition and the result from the ARIA system were compared against a gold standard generated by consulting and aggregating the opinion of 3 retina specialists for each fundus image. RESULTS: The ARIA system was able to classify referable vs nonreferable cases with an area under the receiver operating characteristic curve of 98%, a sensitivity of 95.1%, and a specificity of 91.5% for international patient cases. There was an area under the receiver operating characteristic curve of 98.3%, a sensitivity of 95.2%, and a specificity of 90% for Mexican patient cases. The ARIA system performance was more successful than the average performance of the 17 ophthalmologists enrolled in the study. Additionally, the results suggest that the ARIA system can be useful as an assistive tool, as sensitivity was significantly higher in the experimental condition where ophthalmologists were exposed to the ARIA system's answer prior to their own classification (93.3%), compared with the sensitivity of the condition where participants assessed the images independently (87.3%; P=.05). CONCLUSIONS: These results demonstrate that both independent and assistive use cases of the ARIA system present, for Latin American countries such as Mexico, a substantial opportunity toward expanding the monitoring capacity for the early detection of diabetes-related blindness. 2022-07-26T18:25:50Z 2022-07-26T18:25:50Z 2021 2022-07-26T18:16:41Z Article http://purl.org/eprint/type/JournalArticle https://hdl.handle.net/1721.1/144059 Noriega, Alejandro, Meizner, Daniela, Camacho, Dalia, Enciso, Jennifer, Quiroz-Mercado, Hugo et al. 2021. "Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial." JMIR Formative Research, 5 (8). en 10.2196/25290 JMIR Formative Research Creative Commons Attribution 4.0 International license https://creativecommons.org/licenses/by/4.0/ application/pdf JMIR Publications Inc. JMIR Publications
spellingShingle Noriega, Alejandro
Meizner, Daniela
Camacho, Dalia
Enciso, Jennifer
Quiroz-Mercado, Hugo
Morales-Canton, Virgilio
Almaatouq, Abdullah
Pentland, Alex
Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial
title Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial
title_full Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial
title_fullStr Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial
title_full_unstemmed Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial
title_short Screening Diabetic Retinopathy Using an Automated Retinal Image Analysis System in Independent and Assistive Use Cases in Mexico: Randomized Controlled Trial
title_sort screening diabetic retinopathy using an automated retinal image analysis system in independent and assistive use cases in mexico randomized controlled trial
url https://hdl.handle.net/1721.1/144059
work_keys_str_mv AT noriegaalejandro screeningdiabeticretinopathyusinganautomatedretinalimageanalysissysteminindependentandassistiveusecasesinmexicorandomizedcontrolledtrial
AT meiznerdaniela screeningdiabeticretinopathyusinganautomatedretinalimageanalysissysteminindependentandassistiveusecasesinmexicorandomizedcontrolledtrial
AT camachodalia screeningdiabeticretinopathyusinganautomatedretinalimageanalysissysteminindependentandassistiveusecasesinmexicorandomizedcontrolledtrial
AT encisojennifer screeningdiabeticretinopathyusinganautomatedretinalimageanalysissysteminindependentandassistiveusecasesinmexicorandomizedcontrolledtrial
AT quirozmercadohugo screeningdiabeticretinopathyusinganautomatedretinalimageanalysissysteminindependentandassistiveusecasesinmexicorandomizedcontrolledtrial
AT moralescantonvirgilio screeningdiabeticretinopathyusinganautomatedretinalimageanalysissysteminindependentandassistiveusecasesinmexicorandomizedcontrolledtrial
AT almaatouqabdullah screeningdiabeticretinopathyusinganautomatedretinalimageanalysissysteminindependentandassistiveusecasesinmexicorandomizedcontrolledtrial
AT pentlandalex screeningdiabeticretinopathyusinganautomatedretinalimageanalysissysteminindependentandassistiveusecasesinmexicorandomizedcontrolledtrial