Developing and testing a portable device for tracking small deviations in the hydration levels of a human body

Maintaining proper hydration is widely recognized as essential for overall health, yet dehydration remains a prevalent issue, particularly among vulnerable populations such as the very young and elderly, and can contribute to increased morbidity and mortality rates. There have been numerous endeavor...

Full description

Bibliographic Details
Main Author: Bedi, Saloni
Other Authors: Gray, Martha
Format: Thesis
Published: Massachusetts Institute of Technology 2023
Online Access:https://hdl.handle.net/1721.1/151258
_version_ 1811070733673037824
author Bedi, Saloni
author2 Gray, Martha
author_facet Gray, Martha
Bedi, Saloni
author_sort Bedi, Saloni
collection MIT
description Maintaining proper hydration is widely recognized as essential for overall health, yet dehydration remains a prevalent issue, particularly among vulnerable populations such as the very young and elderly, and can contribute to increased morbidity and mortality rates. There have been numerous endeavors in both academia and industry to develop non-invasive methods for monitoring hydration status, specifically in non-clinical settings. However, a practical and reliable solution for routine hydration measurements is still lacking. To address this critical need, the hydration team at MIT has been actively working on the development of a non-invasive sensor to bridge the gap in hydration monitoring. This thesis focuses on the development of a wearable setup for the existing technology, enabling human studies to be conducted with individuals by comfortably integrating the hydration sensor into their daily routines for study periods of 24 hours and longer. The primary objective of the human studies is to investigate whether the sensor readings obtained during prolonged periods of dehydration can be distinguished from those obtained during normal (euhydrated) activities. Throughout the course of this research, a comprehensive wearable setup was meticulously developed. Human studies were conducted in two distinct cohorts, namely Euhydration and Dehydration, where participants wore the wearable setup to capture hydration data. This allowed for the analysis of hydration trends and would help with a comparative assessment of sensor readings under different conditions. The results obtained and the data analysis facilitates the evaluation of the wearable setup's efficacy and reliability in monitoring hydration status during prolonged periods of dehydration. Furthermore, the findings contribute to the advancement of hydration monitoring by shedding light on the potential of distinguishing between hydration states using the developed wearable setup.
first_indexed 2024-09-23T08:40:42Z
format Thesis
id mit-1721.1/151258
institution Massachusetts Institute of Technology
last_indexed 2024-09-23T08:40:42Z
publishDate 2023
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/1512582023-08-01T04:18:24Z Developing and testing a portable device for tracking small deviations in the hydration levels of a human body Bedi, Saloni Gray, Martha System Design and Management Program. Maintaining proper hydration is widely recognized as essential for overall health, yet dehydration remains a prevalent issue, particularly among vulnerable populations such as the very young and elderly, and can contribute to increased morbidity and mortality rates. There have been numerous endeavors in both academia and industry to develop non-invasive methods for monitoring hydration status, specifically in non-clinical settings. However, a practical and reliable solution for routine hydration measurements is still lacking. To address this critical need, the hydration team at MIT has been actively working on the development of a non-invasive sensor to bridge the gap in hydration monitoring. This thesis focuses on the development of a wearable setup for the existing technology, enabling human studies to be conducted with individuals by comfortably integrating the hydration sensor into their daily routines for study periods of 24 hours and longer. The primary objective of the human studies is to investigate whether the sensor readings obtained during prolonged periods of dehydration can be distinguished from those obtained during normal (euhydrated) activities. Throughout the course of this research, a comprehensive wearable setup was meticulously developed. Human studies were conducted in two distinct cohorts, namely Euhydration and Dehydration, where participants wore the wearable setup to capture hydration data. This allowed for the analysis of hydration trends and would help with a comparative assessment of sensor readings under different conditions. The results obtained and the data analysis facilitates the evaluation of the wearable setup's efficacy and reliability in monitoring hydration status during prolonged periods of dehydration. Furthermore, the findings contribute to the advancement of hydration monitoring by shedding light on the potential of distinguishing between hydration states using the developed wearable setup. S.M. 2023-07-31T19:26:33Z 2023-07-31T19:26:33Z 2023-06 2023-06-23T19:57:49.371Z Thesis https://hdl.handle.net/1721.1/151258 0009-0003-8360-1302 In Copyright - Educational Use Permitted Copyright retained by author(s) https://rightsstatements.org/page/InC-EDU/1.0/ application/pdf Massachusetts Institute of Technology
spellingShingle Bedi, Saloni
Developing and testing a portable device for tracking small deviations in the hydration levels of a human body
title Developing and testing a portable device for tracking small deviations in the hydration levels of a human body
title_full Developing and testing a portable device for tracking small deviations in the hydration levels of a human body
title_fullStr Developing and testing a portable device for tracking small deviations in the hydration levels of a human body
title_full_unstemmed Developing and testing a portable device for tracking small deviations in the hydration levels of a human body
title_short Developing and testing a portable device for tracking small deviations in the hydration levels of a human body
title_sort developing and testing a portable device for tracking small deviations in the hydration levels of a human body
url https://hdl.handle.net/1721.1/151258
work_keys_str_mv AT bedisaloni developingandtestingaportabledevicefortrackingsmalldeviationsinthehydrationlevelsofahumanbody