Two case studies on indoor air quality in New York City decarbonized affordable housing

To mitigate the effects of climate change, building decarbonization and energy efficiency measures have expanded in scope. At the same time, interest has grown in how these changes affect indoor air quality (IAQ) and thus personal health. This thesis analyzes the concentrations of gas pollutants...

Full description

Bibliographic Details
Main Author: Morales, Manuel
Other Authors: Hsu, David
Format: Thesis
Published: Massachusetts Institute of Technology 2023
Online Access:https://hdl.handle.net/1721.1/151636
_version_ 1811079046384058368
author Morales, Manuel
author2 Hsu, David
author_facet Hsu, David
Morales, Manuel
author_sort Morales, Manuel
collection MIT
description To mitigate the effects of climate change, building decarbonization and energy efficiency measures have expanded in scope. At the same time, interest has grown in how these changes affect indoor air quality (IAQ) and thus personal health. This thesis analyzes the concentrations of gas pollutants and particulate matter (PM) within occupied apartments in two New York City affordable housing projects, which we will refer to as Bushwick and Woodlawn. At Bushwick, we explore how gas and PM concentrations are impacted by retrofits that decarbonize the building and increase its energy efficiency to meet passive house standards. At Woodlawn, we monitor PM in a new development built to passive house standards to observe how concentrations are impacted by occupancy and controlled changes to ventilation and filtration settings. Results at Bushwick were limited by the availability of data and confounding factors but indicated the potential for a retrofit to passive house standards to improve IAQ. PM and gas sensors were initially installed in four apartments, but only one apartment (Apt. D) maintained both of these sensors online throughout the study. In addition, one apartment (Apt. A) kept only the PM sensor online and another (Apt. B) kept only the gas sensor online. This ultimately allowed us to analyze changes in PM and gas concentrations in two apartments each. Of note, a few tenants in Apt. D who used to smoke in the unit moved out during the retrofit, so these changes confounded any effect of the retrofit on air pollution that we hoped to observe. We observed statistically significant decreases in most gas and PM pollutants across apartments following the retrofit. PM1 saw the most steep decreases in PM, with mean concentrations dropping 55% in Apt. A and 44% in Apt. D after the retrofit. Amongst gases, mean CO2 concentrations decreased by 62% in Apt. B and 45% in Apt. D. This decrease in air pollution resulted in greater compliance with Health Canada IAQ guidelines after the retrofit. Results at Woodlawn were supported by strong data collection for a year in nine apartment units. By observing air pollution before and after tenants moved in, we determined that occupancy had a statistically significant effect in increasing PM concentrations in all observed apartments. We also observed that the combined effect of increasing ventilation rates by 25% and using in-unit HEPA filters resulted in statistically significant decreases in PM concentrations across most units. Across all interventions in occupancy, ventilation, and filtration, PM2.5 and PM10 concentrations in all units fully complied with WHO ambient air quality guidelines. Furthermore, air pollution indoors was consistently lower than that outdoors, evidence that passive house construction can keep indoor air quality high and protect residents from outdoor air pollution.
first_indexed 2024-09-23T11:09:12Z
format Thesis
id mit-1721.1/151636
institution Massachusetts Institute of Technology
last_indexed 2024-09-23T11:09:12Z
publishDate 2023
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/1516362023-08-01T03:57:11Z Two case studies on indoor air quality in New York City decarbonized affordable housing Morales, Manuel Hsu, David Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science To mitigate the effects of climate change, building decarbonization and energy efficiency measures have expanded in scope. At the same time, interest has grown in how these changes affect indoor air quality (IAQ) and thus personal health. This thesis analyzes the concentrations of gas pollutants and particulate matter (PM) within occupied apartments in two New York City affordable housing projects, which we will refer to as Bushwick and Woodlawn. At Bushwick, we explore how gas and PM concentrations are impacted by retrofits that decarbonize the building and increase its energy efficiency to meet passive house standards. At Woodlawn, we monitor PM in a new development built to passive house standards to observe how concentrations are impacted by occupancy and controlled changes to ventilation and filtration settings. Results at Bushwick were limited by the availability of data and confounding factors but indicated the potential for a retrofit to passive house standards to improve IAQ. PM and gas sensors were initially installed in four apartments, but only one apartment (Apt. D) maintained both of these sensors online throughout the study. In addition, one apartment (Apt. A) kept only the PM sensor online and another (Apt. B) kept only the gas sensor online. This ultimately allowed us to analyze changes in PM and gas concentrations in two apartments each. Of note, a few tenants in Apt. D who used to smoke in the unit moved out during the retrofit, so these changes confounded any effect of the retrofit on air pollution that we hoped to observe. We observed statistically significant decreases in most gas and PM pollutants across apartments following the retrofit. PM1 saw the most steep decreases in PM, with mean concentrations dropping 55% in Apt. A and 44% in Apt. D after the retrofit. Amongst gases, mean CO2 concentrations decreased by 62% in Apt. B and 45% in Apt. D. This decrease in air pollution resulted in greater compliance with Health Canada IAQ guidelines after the retrofit. Results at Woodlawn were supported by strong data collection for a year in nine apartment units. By observing air pollution before and after tenants moved in, we determined that occupancy had a statistically significant effect in increasing PM concentrations in all observed apartments. We also observed that the combined effect of increasing ventilation rates by 25% and using in-unit HEPA filters resulted in statistically significant decreases in PM concentrations across most units. Across all interventions in occupancy, ventilation, and filtration, PM2.5 and PM10 concentrations in all units fully complied with WHO ambient air quality guidelines. Furthermore, air pollution indoors was consistently lower than that outdoors, evidence that passive house construction can keep indoor air quality high and protect residents from outdoor air pollution. M.Eng. 2023-07-31T19:54:47Z 2023-07-31T19:54:47Z 2023-06 2023-06-06T16:35:50.816Z Thesis https://hdl.handle.net/1721.1/151636 In Copyright - Educational Use Permitted Copyright retained by author(s) https://rightsstatements.org/page/InC-EDU/1.0/ application/pdf Massachusetts Institute of Technology
spellingShingle Morales, Manuel
Two case studies on indoor air quality in New York City decarbonized affordable housing
title Two case studies on indoor air quality in New York City decarbonized affordable housing
title_full Two case studies on indoor air quality in New York City decarbonized affordable housing
title_fullStr Two case studies on indoor air quality in New York City decarbonized affordable housing
title_full_unstemmed Two case studies on indoor air quality in New York City decarbonized affordable housing
title_short Two case studies on indoor air quality in New York City decarbonized affordable housing
title_sort two case studies on indoor air quality in new york city decarbonized affordable housing
url https://hdl.handle.net/1721.1/151636
work_keys_str_mv AT moralesmanuel twocasestudiesonindoorairqualityinnewyorkcitydecarbonizedaffordablehousing