UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION

Proceedings of the 2023 Design of Medical Devices Conference DMD2023 April 17-19, 2023, Minneapolis, MN, USA

Bibliographic Details
Main Authors: Reddie, Madison, Eberly, Gari, Jesse Levi, Aviva, Quevedo-Moreno, Diego, Mendez, Keegan, Roche, Ellen T.
Other Authors: Massachusetts Institute of Technology. Department of Mechanical Engineering
Format: Article
Language:English
Published: American Society of Mechanical Engineers 2024
Online Access:https://hdl.handle.net/1721.1/154100
_version_ 1824458118900219904
author Reddie, Madison
Eberly, Gari
Jesse Levi, Aviva
Quevedo-Moreno, Diego
Mendez, Keegan
Roche, Ellen T.
author2 Massachusetts Institute of Technology. Department of Mechanical Engineering
author_facet Massachusetts Institute of Technology. Department of Mechanical Engineering
Reddie, Madison
Eberly, Gari
Jesse Levi, Aviva
Quevedo-Moreno, Diego
Mendez, Keegan
Roche, Ellen T.
author_sort Reddie, Madison
collection MIT
description Proceedings of the 2023 Design of Medical Devices Conference DMD2023 April 17-19, 2023, Minneapolis, MN, USA
first_indexed 2024-09-23T11:54:32Z
format Article
id mit-1721.1/154100
institution Massachusetts Institute of Technology
language English
last_indexed 2025-02-19T04:20:49Z
publishDate 2024
publisher American Society of Mechanical Engineers
record_format dspace
spelling mit-1721.1/1541002025-01-05T04:49:42Z UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION Reddie, Madison Eberly, Gari Jesse Levi, Aviva Quevedo-Moreno, Diego Mendez, Keegan Roche, Ellen T. Massachusetts Institute of Technology. Department of Mechanical Engineering Harvard University--MIT Division of Health Sciences and Technology Massachusetts Institute of Technology. Institute for Medical Engineering & Science Proceedings of the 2023 Design of Medical Devices Conference DMD2023 April 17-19, 2023, Minneapolis, MN, USA Blood clots originating in the left atrial appendage (LAA) are the leading cause of ischemic stroke in patients with nonvalvular atrial fibrillation (AF). Complications from and contraindications to oral anticoagulants (OACs), in addition to the recent successes of endocardial LAA closure devices, have driven increased interest in mechanical LAA occlusion. However, current devices are limited in their abilities to accommodate diverse LAA anatomies, motivating the development of a novel endocardial LAA occluder that supports more anatomical variability. We present the design of an in-situ expandable plug as well as an accompanying pacifier module for LAA occlusion. The final design accommodates LAA diameter ranges of 14 millimeters for each device size (10-24mm and 24-38mm), double that of any approved device. This adaptability can help to overcome imperfect pre-procedural imaging and suboptimal device fit. Benchtop tug and leak tests demonstrate the stability and sealing capacities of the design. 2024-04-09T16:22:05Z 2024-04-09T16:22:05Z 2023-04-17 2024-04-09T16:08:46Z Article http://purl.org/eprint/type/ConferencePaper https://hdl.handle.net/1721.1/154100 Reddie, M, Eberly, G, Jesse Levi, A, Quevedo-Moreno, D, Mendez, K, & Roche, ET. "UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION." Proceedings of the 2023 Design of Medical Devices Conference. 2023 Design of Medical Devices Conference. Minneapolis, MN, USA. April 17–19, 2023. V001T01A001. ASME. en 10.1115/dmd2023-1984 2023 Design of Medical Devices Conference Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. application/pdf American Society of Mechanical Engineers American Society of Mechanical Engineers
spellingShingle Reddie, Madison
Eberly, Gari
Jesse Levi, Aviva
Quevedo-Moreno, Diego
Mendez, Keegan
Roche, Ellen T.
UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION
title UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION
title_full UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION
title_fullStr UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION
title_full_unstemmed UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION
title_short UMBRELAA: DESIGN OF A VARIABLE-SIZED LEFT ATRIAL APPENDAGE OCCLUSION DEVICE FOR STROKE PREVENTION
title_sort umbrelaa design of a variable sized left atrial appendage occlusion device for stroke prevention
url https://hdl.handle.net/1721.1/154100
work_keys_str_mv AT reddiemadison umbrelaadesignofavariablesizedleftatrialappendageocclusiondeviceforstrokeprevention
AT eberlygari umbrelaadesignofavariablesizedleftatrialappendageocclusiondeviceforstrokeprevention
AT jesseleviaviva umbrelaadesignofavariablesizedleftatrialappendageocclusiondeviceforstrokeprevention
AT quevedomorenodiego umbrelaadesignofavariablesizedleftatrialappendageocclusiondeviceforstrokeprevention
AT mendezkeegan umbrelaadesignofavariablesizedleftatrialappendageocclusiondeviceforstrokeprevention
AT rocheellent umbrelaadesignofavariablesizedleftatrialappendageocclusiondeviceforstrokeprevention