Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program

Background Diabetic retinopathy (DR) stands as the foremost cause of preventable blindness in adults. Despite efforts to expand DR screening coverage in the Brazilian public healthcare system, challenges persist due to various factors including social, medical, and financial constra...

Full description

Bibliographic Details
Main Authors: Brant, Rodrigo, Nakayama, Luis Filipe, de Oliveira, Talita Virgínia Fernandes, de Oliveira, Juliana Angelica Estevão, Ribeiro, Lucas Zago, Richter, Gabriela Dalmedico, Rodacki, Rafael, Penha, Fernando Marcondes
Other Authors: Harvard--MIT Program in Health Sciences and Technology. Laboratory for Computational Physiology
Format: Article
Language:English
Published: Springer Science and Business Media LLC 2024
Online Access:https://hdl.handle.net/1721.1/155284
_version_ 1824458304179404800
author Brant, Rodrigo
Nakayama, Luis Filipe
de Oliveira, Talita Virgínia Fernandes
de Oliveira, Juliana Angelica Estevão
Ribeiro, Lucas Zago
Richter, Gabriela Dalmedico
Rodacki, Rafael
Penha, Fernando Marcondes
author2 Harvard--MIT Program in Health Sciences and Technology. Laboratory for Computational Physiology
author_facet Harvard--MIT Program in Health Sciences and Technology. Laboratory for Computational Physiology
Brant, Rodrigo
Nakayama, Luis Filipe
de Oliveira, Talita Virgínia Fernandes
de Oliveira, Juliana Angelica Estevão
Ribeiro, Lucas Zago
Richter, Gabriela Dalmedico
Rodacki, Rafael
Penha, Fernando Marcondes
author_sort Brant, Rodrigo
collection MIT
description Background Diabetic retinopathy (DR) stands as the foremost cause of preventable blindness in adults. Despite efforts to expand DR screening coverage in the Brazilian public healthcare system, challenges persist due to various factors including social, medical, and financial constraints. Our objective was to evaluate the quality of images obtained with the AirDoc, a novel device, compared to Eyer portable camera which has already been clinically validated. Methods Images were captured by two portable retinal devices: AirDoc and Eyer. The included patients had their fundus images obtained in a screening program conducted in Blumenau, Santa Catarina. Two retina specialists independently assessed image’s quality. A comparison was performed between both devices regarding image quality and the presence of artifacts. Results The analysis included 129 patients (mean age of 61 years), with 29 (43.28%) male and an average disease duration of 11.1 ± 8 years. In Ardoc, 21 (16.28%) images were classified as poor quality, with 88 (68%) presenting artifacts; in Eyer, 4 (3.1%) images were classified as poor quality, with 94 (72.87%) presenting artifacts. Conclusions Although both Eyer and AirDoc devices show potential as screening tools, the AirDoc images displayed higher rates of ungradable and low-quality images, that may directly affect the DR and DME grading. We must acknowledge the limitations of our study, including the relatively small sample size. Therefore, the interpretations of our analyses should be approached with caution, and further investigations with larger patient cohorts are warranted to validate our findings.
first_indexed 2024-09-23T14:34:29Z
format Article
id mit-1721.1/155284
institution Massachusetts Institute of Technology
language English
last_indexed 2025-02-19T04:23:46Z
publishDate 2024
publisher Springer Science and Business Media LLC
record_format dspace
spelling mit-1721.1/1552842025-01-02T05:12:55Z Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program Brant, Rodrigo Nakayama, Luis Filipe de Oliveira, Talita Virgínia Fernandes de Oliveira, Juliana Angelica Estevão Ribeiro, Lucas Zago Richter, Gabriela Dalmedico Rodacki, Rafael Penha, Fernando Marcondes Harvard--MIT Program in Health Sciences and Technology. Laboratory for Computational Physiology Background Diabetic retinopathy (DR) stands as the foremost cause of preventable blindness in adults. Despite efforts to expand DR screening coverage in the Brazilian public healthcare system, challenges persist due to various factors including social, medical, and financial constraints. Our objective was to evaluate the quality of images obtained with the AirDoc, a novel device, compared to Eyer portable camera which has already been clinically validated. Methods Images were captured by two portable retinal devices: AirDoc and Eyer. The included patients had their fundus images obtained in a screening program conducted in Blumenau, Santa Catarina. Two retina specialists independently assessed image’s quality. A comparison was performed between both devices regarding image quality and the presence of artifacts. Results The analysis included 129 patients (mean age of 61 years), with 29 (43.28%) male and an average disease duration of 11.1 ± 8 years. In Ardoc, 21 (16.28%) images were classified as poor quality, with 88 (68%) presenting artifacts; in Eyer, 4 (3.1%) images were classified as poor quality, with 94 (72.87%) presenting artifacts. Conclusions Although both Eyer and AirDoc devices show potential as screening tools, the AirDoc images displayed higher rates of ungradable and low-quality images, that may directly affect the DR and DME grading. We must acknowledge the limitations of our study, including the relatively small sample size. Therefore, the interpretations of our analyses should be approached with caution, and further investigations with larger patient cohorts are warranted to validate our findings. 2024-06-17T18:29:58Z 2024-06-17T18:29:58Z 2024-06-14 2024-06-16T03:13:22Z Article http://purl.org/eprint/type/JournalArticle 2056-9920 https://hdl.handle.net/1721.1/155284 Brant, R., Nakayama, L.F., de Oliveira, T.V.F. et al. Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program. Int J Retin Vitr 10, 43 (2024). PUBLISHER_CC en 10.1186/s40942-024-00559-z International Journal of Retina and Vitreous Creative Commons Attribution https://creativecommons.org/licenses/by/4.0/ The Author(s) application/pdf Springer Science and Business Media LLC BioMed Central
spellingShingle Brant, Rodrigo
Nakayama, Luis Filipe
de Oliveira, Talita Virgínia Fernandes
de Oliveira, Juliana Angelica Estevão
Ribeiro, Lucas Zago
Richter, Gabriela Dalmedico
Rodacki, Rafael
Penha, Fernando Marcondes
Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program
title Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program
title_full Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program
title_fullStr Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program
title_full_unstemmed Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program
title_short Image quality comparison of AirDoc portable retina camera versus eyer in a diabetic retinopathy screening program
title_sort image quality comparison of airdoc portable retina camera versus eyer in a diabetic retinopathy screening program
url https://hdl.handle.net/1721.1/155284
work_keys_str_mv AT brantrodrigo imagequalitycomparisonofairdocportableretinacameraversuseyerinadiabeticretinopathyscreeningprogram
AT nakayamaluisfilipe imagequalitycomparisonofairdocportableretinacameraversuseyerinadiabeticretinopathyscreeningprogram
AT deoliveiratalitavirginiafernandes imagequalitycomparisonofairdocportableretinacameraversuseyerinadiabeticretinopathyscreeningprogram
AT deoliveirajulianaangelicaestevao imagequalitycomparisonofairdocportableretinacameraversuseyerinadiabeticretinopathyscreeningprogram
AT ribeirolucaszago imagequalitycomparisonofairdocportableretinacameraversuseyerinadiabeticretinopathyscreeningprogram
AT richtergabrieladalmedico imagequalitycomparisonofairdocportableretinacameraversuseyerinadiabeticretinopathyscreeningprogram
AT rodackirafael imagequalitycomparisonofairdocportableretinacameraversuseyerinadiabeticretinopathyscreeningprogram
AT penhafernandomarcondes imagequalitycomparisonofairdocportableretinacameraversuseyerinadiabeticretinopathyscreeningprogram