A methodology for assessing MIT's energy used and greenhouse gas emissions

Includes bibliographical references (p. 131).

Bibliographic Details
Main Author: Groode, Tiffany Amber, 1979-
Other Authors: John Heywood.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2005
Subjects:
Online Access:http://hdl.handle.net/1721.1/17926
_version_ 1811086810593361920
author Groode, Tiffany Amber, 1979-
author2 John Heywood.
author_facet John Heywood.
Groode, Tiffany Amber, 1979-
author_sort Groode, Tiffany Amber, 1979-
collection MIT
description Includes bibliographical references (p. 131).
first_indexed 2024-09-23T13:35:02Z
format Thesis
id mit-1721.1/17926
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T13:35:02Z
publishDate 2005
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/179262019-04-12T21:46:32Z A methodology for assessing MIT's energy used and greenhouse gas emissions A methodology for assessing Massachusetts Institute of Technology's energy used and greenhouse gas emissions Groode, Tiffany Amber, 1979- John Heywood. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Includes bibliographical references (p. 131). Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004. (cont.) actions can be made to decrease losses and therefore increase plant efficiencies. As production efficiencies are maximized, fuel use and thus emissions are minimized. From fiscal year 1998 to 2003, the gas turbine efficiency, based on the higher heating value, remained approximately constant at 24%. The heat recovery steam generator effectiveness has decreased 11% from 42.1% to 37.4%. It has been shown that the decrease in the heat recovery steam generator's performance can be attributed to fouling effects on the heat transfer surfaces between the hot exhaust gasses and the water stream. An accurate inventory of MIT's greenhouse gas emissions is a necessary first step in reducing these emissions. This assessment identifies areas with the greatest potential for reducing utility related emissions. This inventory will also allow MIT to continue to evaluate its greenhouse gas emission trends and thus contribute to the emission reduction target the city of Cambridge has created. This MIT campus emission assessment has been done in response to the City of Cambridge Climate Protection Plan, which is calling for a 20% decrease in greenhouse gas emissions from 1990 levels by the year 2010. This greenhouse gas inventory includes all emissions of carbon dioxide, methane, and nitrous oxide due to utility use from fiscal year 1990 to 2003 and estimates of transportation and solid waste emissions. It accounts for utilities purchased and utilities produced from the MIT Cogeneration Power Plant. A methodology has been developed to allocate the MIT utility plant addition, the assessment includes carbon dioxide emissions due to the MIT commuting population from fiscal year 1999 to 2003, and accounts for equivalent carbon dioxide emissions from solid waste incineration from fiscal year 2000 to 2003. The 20% reduction target from 1990 emission levels sets a cap on campus emissions of 163,830 equivalent metric tons of carbon dioxide per year. At current levels, a 22% decrease in emissions would be required to achieve this target. Emissions released from utility use account for 90% of the campus emissions, with 9.5% attributed to commuters, and 0.5% emissions based on produced electricity, steam, and chilled water. This allows facilities to develop programs that will directly impact the source of highest emissions. In due to campus solid waste. Therefore, reducing the amount of emissions caused by utility production and purchasing would have the largest effect on reducing the total campus greenhouse gas emissions. A thermodynamic availability flow analysis has also been conducted on the gas turbine and heat recovery steam generator system of the MIT cogeneration power plan. Availability losses within the system were targeted and appropriate by Tiffany Amber Groode. S.M. 2005-06-02T19:12:49Z 2005-06-02T19:12:49Z 2004 2004 Thesis http://hdl.handle.net/1721.1/17926 56803019 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 131 p. 6964260 bytes 6964455 bytes application/pdf application/pdf application/pdf Massachusetts Institute of Technology
spellingShingle Mechanical Engineering.
Groode, Tiffany Amber, 1979-
A methodology for assessing MIT's energy used and greenhouse gas emissions
title A methodology for assessing MIT's energy used and greenhouse gas emissions
title_full A methodology for assessing MIT's energy used and greenhouse gas emissions
title_fullStr A methodology for assessing MIT's energy used and greenhouse gas emissions
title_full_unstemmed A methodology for assessing MIT's energy used and greenhouse gas emissions
title_short A methodology for assessing MIT's energy used and greenhouse gas emissions
title_sort methodology for assessing mit s energy used and greenhouse gas emissions
topic Mechanical Engineering.
url http://hdl.handle.net/1721.1/17926
work_keys_str_mv AT groodetiffanyamber1979 amethodologyforassessingmitsenergyusedandgreenhousegasemissions
AT groodetiffanyamber1979 amethodologyforassessingmassachusettsinstituteoftechnologysenergyusedandgreenhousegasemissions
AT groodetiffanyamber1979 methodologyforassessingmitsenergyusedandgreenhousegasemissions