Improvement of the environmental and economic characteristics of cooling towers : [Part 1] The periodic cooling tower - small scale, full scale, and surface roughening tests

Prepared in association with Heat Transfer Laboratory, Dept. of Mechanical Engineering

Bibliographic Details
Main Author: Hon, Pou Cheong
Format: Technical Report
Language:en_US
Published: MIT Energy Lab 2005
Subjects:
Online Access:http://hdl.handle.net/1721.1/27527
_version_ 1826203380831223808
author Hon, Pou Cheong
author_facet Hon, Pou Cheong
author_sort Hon, Pou Cheong
collection MIT
description Prepared in association with Heat Transfer Laboratory, Dept. of Mechanical Engineering
first_indexed 2024-09-23T12:36:01Z
format Technical Report
id mit-1721.1/27527
institution Massachusetts Institute of Technology
language en_US
last_indexed 2024-09-23T12:36:01Z
publishDate 2005
publisher MIT Energy Lab
record_format dspace
spelling mit-1721.1/275272019-04-11T02:45:38Z Improvement of the environmental and economic characteristics of cooling towers : [Part 1] The periodic cooling tower - small scale, full scale, and surface roughening tests Hon, Pou Cheong Cooling towers Prepared in association with Heat Transfer Laboratory, Dept. of Mechanical Engineering This report describes research for the past year on methods to enhance the environmental and economic performance of dry cooling towers. The work has concentrated on dry cooling towers utilizing periodic water to air heat exchangers. Periodic towers have sheet metal discs partially submerged in hot, power plant condenser effluent. As the discs rotate, the discs alternately absorb heat from the effluent and discharge heat to the air. The means of heat transfer on the air side can be either evaporative and/or convective, depending upon the amount of effluent carried into the air side on the surface of the plates. An oil layer, floated on the water's surface, has been shown to be effective in eliminating water carry-over to the air side. The advantages of the periodic tower lie in the low cost of the discs and the ability to operate dry . A periodic tower should be significantly less expensive than a conventional dry tower fabricated with finned tubes. Further, since the periodic tower can also operate wet, by removing the oil film, the high capacity losses incurred during warm months by conventional dry towers can be eliminated. In the past year, tests on a 20 inch model of the periodic tower indicated that at operational speeds of the full sized disc, no noticeable churning of the oil layer ocurred. Heat transfer rates measured with the 20 inch model were 20 percent higher than predicted by an approximate analysis. Finally, silicone oils' low vapor pressure make them superior to hydrocarbon oils on the basis of evaporation rates, but their higher costs and possible ecological impact necessitates a closer look at hydrocarbon oils. Construction of the full scale test facility is complete. Shaped, rigid five foot diameter discs have been designed, fabricated, and assembled into an initial test module. Instrumentation for heat transfer tests is also complete; including instrumentation for measuring disc temperatures, and both air and water flow rates and temperatures. A parametric study of the oil film thickness on the air side of the test module has been completed. Measured thicknesses were 20 percent less than that previously predicted. This thinner oil layer means an increase in the disc heat transfer. A test apparatus to study the further enhancement of disc performance by surface roughening has been constructed, instrumented and calibrated. The apparatus has reproduced experimental friction factor and heat transfer coefficient curves for flat plates, and will be used to evaluate enhancement as a function of rib shape, size, spacings and Reynold's number. Visits to several architectural engineers across the country were made with representatives of Air Preheater Company to gage their acceptance of the rotary concept. All felt that if the reliability of the rotary concept could be demonstrated and the costs were less than equivalent conventional dry towers, the rotary desing would be the preferred choice. Based on these findings, Air Preheater is planning to do design and cost studies of the rotary concept for the coming year. Empire State Electric Energy Research Corporation, New York 2005-09-21T20:29:18Z 2005-09-21T20:29:18Z 1975 Technical Report 02176071 http://hdl.handle.net/1721.1/27527 en_US MIT-EL 75-018 5455418 bytes application/pdf application/pdf MIT Energy Lab
spellingShingle Cooling towers
Hon, Pou Cheong
Improvement of the environmental and economic characteristics of cooling towers : [Part 1] The periodic cooling tower - small scale, full scale, and surface roughening tests
title Improvement of the environmental and economic characteristics of cooling towers : [Part 1] The periodic cooling tower - small scale, full scale, and surface roughening tests
title_full Improvement of the environmental and economic characteristics of cooling towers : [Part 1] The periodic cooling tower - small scale, full scale, and surface roughening tests
title_fullStr Improvement of the environmental and economic characteristics of cooling towers : [Part 1] The periodic cooling tower - small scale, full scale, and surface roughening tests
title_full_unstemmed Improvement of the environmental and economic characteristics of cooling towers : [Part 1] The periodic cooling tower - small scale, full scale, and surface roughening tests
title_short Improvement of the environmental and economic characteristics of cooling towers : [Part 1] The periodic cooling tower - small scale, full scale, and surface roughening tests
title_sort improvement of the environmental and economic characteristics of cooling towers part 1 the periodic cooling tower small scale full scale and surface roughening tests
topic Cooling towers
url http://hdl.handle.net/1721.1/27527
work_keys_str_mv AT honpoucheong improvementoftheenvironmentalandeconomiccharacteristicsofcoolingtowerspart1theperiodiccoolingtowersmallscalefullscaleandsurfacerougheningtests