Effects of Applied Loads, Effective Contact Area and Surface Roughness on the Dicing Yield of 3D Cu Bonded Interconnects

Bonded copper interconnects were created using thermo-compression bonding and the dicing yield was used as an indication of the bond quality. SEM images indicated that the Cu was plastically deformed. Our experimental and modeling results indicate that the effective contact area is directly proporti...

Full description

Bibliographic Details
Main Authors: Leong, Hoi Liong, Gan, C.L., Pey, Kin Leong, Thompson, Carl V., Li, Hongyu
Format: Article
Language:English
Published: 2005
Subjects:
Online Access:http://hdl.handle.net/1721.1/29818
_version_ 1826211322254065664
author Leong, Hoi Liong
Gan, C.L.
Pey, Kin Leong
Thompson, Carl V.
Li, Hongyu
author_facet Leong, Hoi Liong
Gan, C.L.
Pey, Kin Leong
Thompson, Carl V.
Li, Hongyu
author_sort Leong, Hoi Liong
collection MIT
description Bonded copper interconnects were created using thermo-compression bonding and the dicing yield was used as an indication of the bond quality. SEM images indicated that the Cu was plastically deformed. Our experimental and modeling results indicate that the effective contact area is directly proportional to the applied load. Furthermore, for first time, results have been obtained that indicate that the dicing yield is proportional to the measured bond strength, and the bond strength is proportional to the effective contact area. It is also shown that films with rougher surfaces (and corresponding lower effective bonding areas) have lower bond strengths and dicing yields. A quantitative model for the relationship between measured surface roughness and the corresponding dicing yield has been developed. An appropriate surface-roughness data acquisition methodology has also been developed. The maximum possible applied load and the minimum possible surface roughness are required to obtain the maximum effective contact area, and hence to achieve optimum yields (both mechanically and electrically).
first_indexed 2024-09-23T15:04:05Z
format Article
id mit-1721.1/29818
institution Massachusetts Institute of Technology
language English
last_indexed 2024-09-23T15:04:05Z
publishDate 2005
record_format dspace
spelling mit-1721.1/298182019-04-12T08:25:34Z Effects of Applied Loads, Effective Contact Area and Surface Roughness on the Dicing Yield of 3D Cu Bonded Interconnects Leong, Hoi Liong Gan, C.L. Pey, Kin Leong Thompson, Carl V. Li, Hongyu Cu-Cu thermo-compression bonding wafer-wafer bonding Bonded copper interconnects were created using thermo-compression bonding and the dicing yield was used as an indication of the bond quality. SEM images indicated that the Cu was plastically deformed. Our experimental and modeling results indicate that the effective contact area is directly proportional to the applied load. Furthermore, for first time, results have been obtained that indicate that the dicing yield is proportional to the measured bond strength, and the bond strength is proportional to the effective contact area. It is also shown that films with rougher surfaces (and corresponding lower effective bonding areas) have lower bond strengths and dicing yields. A quantitative model for the relationship between measured surface roughness and the corresponding dicing yield has been developed. An appropriate surface-roughness data acquisition methodology has also been developed. The maximum possible applied load and the minimum possible surface roughness are required to obtain the maximum effective contact area, and hence to achieve optimum yields (both mechanically and electrically). Singapore-MIT Alliance (SMA) 2005-12-12T16:15:35Z 2005-12-12T16:15:35Z 2006-01 Article http://hdl.handle.net/1721.1/29818 en Advanced Materials for Micro- and Nano-Systems (AMMNS) 412699 bytes application/pdf application/pdf
spellingShingle Cu-Cu thermo-compression bonding
wafer-wafer bonding
Leong, Hoi Liong
Gan, C.L.
Pey, Kin Leong
Thompson, Carl V.
Li, Hongyu
Effects of Applied Loads, Effective Contact Area and Surface Roughness on the Dicing Yield of 3D Cu Bonded Interconnects
title Effects of Applied Loads, Effective Contact Area and Surface Roughness on the Dicing Yield of 3D Cu Bonded Interconnects
title_full Effects of Applied Loads, Effective Contact Area and Surface Roughness on the Dicing Yield of 3D Cu Bonded Interconnects
title_fullStr Effects of Applied Loads, Effective Contact Area and Surface Roughness on the Dicing Yield of 3D Cu Bonded Interconnects
title_full_unstemmed Effects of Applied Loads, Effective Contact Area and Surface Roughness on the Dicing Yield of 3D Cu Bonded Interconnects
title_short Effects of Applied Loads, Effective Contact Area and Surface Roughness on the Dicing Yield of 3D Cu Bonded Interconnects
title_sort effects of applied loads effective contact area and surface roughness on the dicing yield of 3d cu bonded interconnects
topic Cu-Cu thermo-compression bonding
wafer-wafer bonding
url http://hdl.handle.net/1721.1/29818
work_keys_str_mv AT leonghoiliong effectsofappliedloadseffectivecontactareaandsurfaceroughnessonthedicingyieldof3dcubondedinterconnects
AT gancl effectsofappliedloadseffectivecontactareaandsurfaceroughnessonthedicingyieldof3dcubondedinterconnects
AT peykinleong effectsofappliedloadseffectivecontactareaandsurfaceroughnessonthedicingyieldof3dcubondedinterconnects
AT thompsoncarlv effectsofappliedloadseffectivecontactareaandsurfaceroughnessonthedicingyieldof3dcubondedinterconnects
AT lihongyu effectsofappliedloadseffectivecontactareaandsurfaceroughnessonthedicingyieldof3dcubondedinterconnects