A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems

Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1995.

Bibliographic Details
Main Author: DeSimone, Mark
Other Authors: Leslie K. Norford.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2007
Subjects:
Online Access:http://hdl.handle.net/1721.1/37035
_version_ 1811081212169551872
author DeSimone, Mark
author2 Leslie K. Norford.
author_facet Leslie K. Norford.
DeSimone, Mark
author_sort DeSimone, Mark
collection MIT
description Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1995.
first_indexed 2024-09-23T11:43:13Z
format Thesis
id mit-1721.1/37035
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T11:43:13Z
publishDate 2007
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/370352019-04-10T12:31:17Z A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems DeSimone, Mark Leslie K. Norford. Massachusetts Institute of Technology. Dept. of Architecture Architecture Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1995. Includes bibliographical references. The parameters for a dynamic, computer simulation model were developed. The parameters characterize the physical and geometric properties of a building shell, the internal and external building loads, the buildings secondary systems, and the plant or primary energy source. The purpose of the model is to provide a standard testbed for the evaluation of control algorithms and strategies related to variable air volume HVAC systems. This work was conducted in collaboration with, and under subcontract to Loughborough University of Technology, Loughborough England. The prototype building is a four level commercial, multi-use building and activities in the building include classroom / educational space professorial and student offices, and office / administrative. The building contains three air-handling units; one unit and the volume it serves provides the basis for the testbed. The model volume is divided into thirty four zones, each with its own single duct, pressure independent V A V terminal box with hot water reheat. A perimeter heating system, composed of hot water convectors, radiators and baseboard heaters, augments the room comfort control system. Local loop control in the mechanical room and for all but one of the zones is micro-processor based pneumatic actuated. One prototype direct digital control terminal box system was in use for a classroom zone. DDC control systems and motor driven actuators were substituted in the testbed for the pneumatic equipment. Zoning in the volume was redistributed into six zones; the supply and return duct system was redesigned to accommodate the simplified zone configuration. A survey was conducted to determine the availability of sub-one-hour solar and collateral weather data. Historically, data in this frequency has been collected, but, not reported. A relatively new program called the Automated Surface Observing System (AS OS) and operated by the National Oceanic and Atmospheric Administration will eventually provide weather data at varying intervals down to one minute, depending on the type of information required. Daily and monthly summaries are available, however, resolution is reduced and averaged to one hour intervals. The SOLMET program, under the auspices of DOE, provides archived solar data at one hour intervals on CD Rom. Data is collected from twenty-six stations distributed around the United States. Collateral weather data is also provided with the solar data and for simulation purposes the SOLMET data provides the best resource. by Mark DeSimone. M.S. 2007-04-03T17:03:53Z 2007-04-03T17:03:53Z 1995 1995 Thesis http://hdl.handle.net/1721.1/37035 36815868 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 554 p. application/pdf Massachusetts Institute of Technology
spellingShingle Architecture
DeSimone, Mark
A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems
title A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems
title_full A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems
title_fullStr A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems
title_full_unstemmed A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems
title_short A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems
title_sort standard simulation testbed for the evaluation of control algorithms strategies related to variable air volume hvac systems
topic Architecture
url http://hdl.handle.net/1721.1/37035
work_keys_str_mv AT desimonemark astandardsimulationtestbedfortheevaluationofcontrolalgorithmsstrategiesrelatedtovariableairvolumehvacsystems
AT desimonemark standardsimulationtestbedfortheevaluationofcontrolalgorithmsstrategiesrelatedtovariableairvolumehvacsystems