Power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors

Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2008.

Bibliographic Details
Main Author: Gibbs, Jonathan Paul
Other Authors: Pravel Hejzlar and Michael J. Driscoll.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2009
Subjects:
Online Access:http://hdl.handle.net/1721.1/44765
_version_ 1826208546065219584
author Gibbs, Jonathan Paul
author2 Pravel Hejzlar and Michael J. Driscoll.
author_facet Pravel Hejzlar and Michael J. Driscoll.
Gibbs, Jonathan Paul
author_sort Gibbs, Jonathan Paul
collection MIT
description Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2008.
first_indexed 2024-09-23T14:07:02Z
format Thesis
id mit-1721.1/44765
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T14:07:02Z
publishDate 2009
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/447652019-04-12T15:26:56Z Power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors Gibbs, Jonathan Paul Pravel Hejzlar and Michael J. Driscoll. Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering. Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering. Nuclear Science and Engineering. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2008. "June 2008." Includes bibliographical references. The supercritical carbon dioxide (S-CO₂) cycle is a promising advanced power conversion cycle which couples nicely to many Generation IV nuclear reactors. This work investigates the power conversion system design and proposes several "Third Generation" plant layouts for power ratings ranging between 20 and 1200 MWe for the recompression cycle. A 20 MWe simple cycle layout was also developed. The cycle designs are characterized by a dispersed component layout in which a single shaft turbomachinery train is coupled to parallel arrays of multiple printed circuit heat exchanger modules. This configuration has arrangement benefits in terms of modularity, inspectability, repairability and replaceability. Compared to the prior second generation dispersed layouts, its lower ductwork pressure drop confers approximately 2% higher thermal efficiency. Two alternative S-CO₂ cycle designs for medium power applications were developed using an in-house optimization computer code and Solid Edge software. The first design is a recompression cycle derived from the 300 MWe design developed at MIT for Generation IV reactors. The design employs one turbine, two compressors (main and recompression) working in parallel and two recuperators (high and low temperature) and maximizes cycle efficiency while striving for a small plant footprint. The second design is a simple S-CO₂ power cycle, which has only one turbine, one compressor, and one recuperator. The main focus of the simple S-CO₂ design is cycle compactness and simplicity while achieving still attractive efficiency. Extensive sensitivity studies were performed for both the medium power recompression and simple S-CO₂ cycles to reveal areas for performance improvement, or performance degradation. Cycle efficiency is most sensitive to turbine inlet temperature. (cont.) Peak cycle pressure is also an important parameter affecting cycle efficiency, although to a smaller extent than turbine inlet temperature. Higher pressure gives higher efficiency, but this gradually saturates around 28 MPa. Other sensitivity studies included turbomachinery performance, cooling water temperature, and heat exchanger fouling and plugging The reference parameters chosen are a 650°C turbine inlet temperature and 20 MPa peak cycle pressure (compressor outlet) because they reach a high thermodynamic efficiency (~/~47-48%) while staying within materials limitations. In order to couple the cycle to many of the Generation IV nuclear reactors a second reference case was chosen with a turbine inlet temperature of 550°C and a peak cycle pressure of 20 MPa. by Jonathan Paul Gibbs. S.M. 2009-03-16T19:40:13Z 2009-03-16T19:40:13Z 2008 Thesis http://hdl.handle.net/1721.1/44765 300273946 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 207 p. application/pdf Massachusetts Institute of Technology
spellingShingle Nuclear Science and Engineering.
Gibbs, Jonathan Paul
Power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors
title Power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors
title_full Power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors
title_fullStr Power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors
title_full_unstemmed Power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors
title_short Power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors
title_sort power conversion system design for supercritical carbon dioxide cooled indirect cycle nuclear reactors
topic Nuclear Science and Engineering.
url http://hdl.handle.net/1721.1/44765
work_keys_str_mv AT gibbsjonathanpaul powerconversionsystemdesignforsupercriticalcarbondioxidecooledindirectcyclenuclearreactors