Drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices

Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.

Bibliographic Details
Main Author: Shieh, Sarah
Other Authors: Anette E. Hosoi.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2010
Subjects:
Online Access:http://hdl.handle.net/1721.1/54495
_version_ 1811071138250358784
author Shieh, Sarah
author2 Anette E. Hosoi.
author_facet Anette E. Hosoi.
Shieh, Sarah
author_sort Shieh, Sarah
collection MIT
description Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.
first_indexed 2024-09-23T08:46:37Z
format Thesis
id mit-1721.1/54495
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T08:46:37Z
publishDate 2010
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/544952019-04-10T07:27:38Z Drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices Shieh, Sarah Anette E. Hosoi. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009. Cataloged from PDF version of thesis. Includes bibliographical references (p. 23-24). An experimental study was carried out to determine if drag reducing polymers can be simple indicators of hemolytic potential in biomechanical devices. Specifically, three different blood pumps, known as a left ventricle assist devices (LVADs) were operated in a test loop using an aqueous solution of polyethylene glycol (PEO, MW = 5000 kDa), a known drag reducing polymer. The pumps were operated under controlled parameters and the change in viscosity (cP) and drag reduction (%DR) for each pump was monitored over the specified time period. The CentriMag® (CM) was used to confirm the drag reducing behavior of PEO, while HeartMate® II (HM II) and HeartMate® III (HM III) were used to determine if there was a correlation between experimental results and actual hemolysis results. Experimental results showed that the mathematical difference between the average final and initial viscosity of HM II was greater than the difference for HM III. HM II had a difference of 0.21 cP and HM III had a difference of 0.16 cP. Hemolysis results using bovine blood showed that HM II had a higher hemolysis rate of 3.80 +/- 1.11 g/day and a higher milligram normalized index of hemolysis of 0.0393 +/- 0.0155. The average hemolysis rate for HM III was 1.38 +/- 0.63 g/day and the milligram normalized index of hemolysis (mg N.I.H.) was 0.571 +/- 0.333. This positive correlation shows that PEO can be a simple indicator of hemolytic potential for biomechanical devices. More data and experimentation is needed to further understand the behavior of PEO and it's ability to indicate hemolytic potential using a wider range of biomechanical devices. by Sarah Shieh. S.B. 2010-04-28T15:42:13Z 2010-04-28T15:42:13Z 2009 2009 Thesis http://hdl.handle.net/1721.1/54495 558634750 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 24 p. application/pdf Massachusetts Institute of Technology
spellingShingle Mechanical Engineering.
Shieh, Sarah
Drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices
title Drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices
title_full Drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices
title_fullStr Drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices
title_full_unstemmed Drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices
title_short Drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices
title_sort drag reducing polymers as simple indicators of hemolytic potential in biomechanical devices
topic Mechanical Engineering.
url http://hdl.handle.net/1721.1/54495
work_keys_str_mv AT shiehsarah dragreducingpolymersassimpleindicatorsofhemolyticpotentialinbiomechanicaldevices