Flow regimes, local heat transfer coefficients, and temperature distributions along the wall have been studied for film boiling inside a vertical tube with upward flow of a saturated liquid. The area of interest has been limited to cases of constant heat flux from the tube wall, small inlet liquid v...

Full description

Bibliographic Details
Main Authors: Dougall, R. S., Rohsenow, Warren M.
Other Authors: Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Format: Technical Report
Published: Cambridge, Mass. : Dept. of Mechanical Engineering, Massachusetts Institute of Technology, [1963] 2011
Online Access:http://hdl.handle.net/1721.1/62142
Description
Summary:Flow regimes, local heat transfer coefficients, and temperature distributions along the wall have been studied for film boiling inside a vertical tube with upward flow of a saturated liquid. The area of interest has been limited to cases of constant heat flux from the tube wall, small inlet liquid velocities, and film boiling which completely covers the entire heated portion of the tube. The last restriction means that there is no large region of nucleate boiling prior to the film boiling section. A visual test section made of electrically conducting glass tubing has been used for flow visualization studies at low qualities. Visual observations with this test section have indicated that the flow regime is annular with liquid in the center and vapor along the walls of the tube. Based on interpretations of temperature distribution data, it has been concluded that the annular flow regime changes at higher qualities to one of dispersed flow--where the liquid is dispersed in the form of drops through a predominately vapor flow. Two different diameter test sections made of stainless steel and heated electrically have been used to obtain experimental data of temperature distributions along the tube wall and local Nusselt numbers for different heat fluxes and flow rates. The fluid used in all the experimental tests has been freon 113. For the larger tube, 0.408" I.D., heat fluxes have been varied from 14,400 to 25,600 Btu/hr-ft2 , and mass velocities have been varied from 482,000 to 818,000 lbm/hr-ft2 . For these conditions, values of heat transfer coefficients from 24.0 to 41.4 Btu/hr-ft 2 -*F and values of Tw-Ts from 407 to 697*F have been obtained. These conditions have resulted in exit qualities up to 10 per cent. For the smaller tube, 0.180" I.D., heat fluxes have been varied from 22,500 to 41,800 Btu/hr-ft2 , and mass velocities have been varied from 332,000 to 398,000 lbm/hr-ft". For these conditions, values of heat