Label-free buoyant mass assays with suspended microchannel resonators
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Biological Engineering, 2010.
Main Author: | |
---|---|
Other Authors: | |
Format: | Thesis |
Language: | eng |
Published: |
Massachusetts Institute of Technology
2011
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/62389 |
_version_ | 1826194868964163584 |
---|---|
author | Von Muhlen, Marcio Goldani |
author2 | Scott R. Manalis. |
author_facet | Scott R. Manalis. Von Muhlen, Marcio Goldani |
author_sort | Von Muhlen, Marcio Goldani |
collection | MIT |
description | Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Biological Engineering, 2010. |
first_indexed | 2024-09-23T10:03:07Z |
format | Thesis |
id | mit-1721.1/62389 |
institution | Massachusetts Institute of Technology |
language | eng |
last_indexed | 2024-09-23T10:03:07Z |
publishDate | 2011 |
publisher | Massachusetts Institute of Technology |
record_format | dspace |
spelling | mit-1721.1/623892019-04-11T05:35:27Z Label-free buoyant mass assays with suspended microchannel resonators Von Muhlen, Marcio Goldani Scott R. Manalis. Massachusetts Institute of Technology. Dept. of Biological Engineering. Massachusetts Institute of Technology. Dept. of Biological Engineering. Biological Engineering. Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Biological Engineering, 2010. Cataloged from PDF version of thesis. Includes bibliographical references (p. 105-112). Improved methods are needed for routine, inexpensive monitoring of biomarkers that could facilitate earlier detection and characterization of complex diseases like cancer. Development of new assay formats based on microfluidic, label-free platforms enable radical reductions in assay complexity and reagent requirements with the potential for such applications. Suspended microchannel resonators (SMRs) are highly sensitive, batch-fabricated microcantilevers with embedded microchannels that can measure mass with femtogram precision. Biomolecules such as proteins and nucleic acids are denser than water, and their presence can thus be quantified by their buoyant mass, or increase in mass relative to the solution they displace. This thesis presents two approaches to conducting label-free, buoyant-mass immunoassays with SMRs with potential for clinical applications. The sensor surface can be functionalized to bind targets directly, or individually weighed polystyrene beads can be used as mobile supports. As in other label-free detection methods, biomolecular measurements in complex media such as serum are challenging due to high background signals from non-specific binding. We demonstrate that carboxybetaine-derived polymers developed to adsorb directly onto SMR SiO2 surfaces act as ultra-low fouling and functionalizable surface coatings. Coupled with a reference microcantilever, this approach enables detection of activated leukocyte cell adhesion molecule (ALCAM), a model cancer biomarker, in undiluted serum with a limit of detection of 10 ng/mL. Decoupling the complexity of surface modifications from the sensor precludes the need for specialized reagents. Monodisperse, micron-scale polystyrene beads are widely available and can be used as mobile supports, with the mean mass of a bead population quantifying target binding onto bead surfaces. Inherent mass variability in the bead population is masked by matching solution density to bead density. We demonstrate that by weighing hundreds of beads in 30 min, mean mass can be estimated with a resolution of 100 attograms. A proof-of-principle assay is demonstrated that quantifies IgG binding onto functionalized beads at 5.20 femtograms per bead. by Marcio Goldani von Muhlen. Ph.D. 2011-04-25T15:51:19Z 2011-04-25T15:51:19Z 2010 2010 Thesis http://hdl.handle.net/1721.1/62389 710079805 eng MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582 112 p. application/pdf Massachusetts Institute of Technology |
spellingShingle | Biological Engineering. Von Muhlen, Marcio Goldani Label-free buoyant mass assays with suspended microchannel resonators |
title | Label-free buoyant mass assays with suspended microchannel resonators |
title_full | Label-free buoyant mass assays with suspended microchannel resonators |
title_fullStr | Label-free buoyant mass assays with suspended microchannel resonators |
title_full_unstemmed | Label-free buoyant mass assays with suspended microchannel resonators |
title_short | Label-free buoyant mass assays with suspended microchannel resonators |
title_sort | label free buoyant mass assays with suspended microchannel resonators |
topic | Biological Engineering. |
url | http://hdl.handle.net/1721.1/62389 |
work_keys_str_mv | AT vonmuhlenmarciogoldani labelfreebuoyantmassassayswithsuspendedmicrochannelresonators |