Ventilative cooling
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Architecture, 1999.
Main Author: | |
---|---|
Other Authors: | |
Format: | Thesis |
Language: | eng |
Published: |
Massachusetts Institute of Technology
2011
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/66785 |
_version_ | 1826210668899991552 |
---|---|
author | Graça, Guilherme Carrilho da, 1972- |
author2 | Qingyan Chen. |
author_facet | Qingyan Chen. Graça, Guilherme Carrilho da, 1972- |
author_sort | Graça, Guilherme Carrilho da, 1972- |
collection | MIT |
description | Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Architecture, 1999. |
first_indexed | 2024-09-23T14:53:35Z |
format | Thesis |
id | mit-1721.1/66785 |
institution | Massachusetts Institute of Technology |
language | eng |
last_indexed | 2024-09-23T14:53:35Z |
publishDate | 2011 |
publisher | Massachusetts Institute of Technology |
record_format | dspace |
spelling | mit-1721.1/667852019-04-11T06:53:56Z Ventilative cooling Graça, Guilherme Carrilho da, 1972- Qingyan Chen. Massachusetts Institute of Technology. Dept. of Architecture. Massachusetts Institute of Technology. Dept. of Architecture. Architecture. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Architecture, 1999. Includes bibliographical references (p. 131-134). This thesis evaluates the performance of daytime and nighttime passive ventilation cooling strategies for Beijing, Shanghai and Tokyo. A new simulation method for cross-ventilated wind driven airflow is presented . This method decouples the airflow model from the thermal model allowing for fast real weather simulation of the building thermal performance. The simulation is performed on a six-story, isolated, suburban apartment building, considered to be typical of the three cities. The performance of the two natural ventilation strategies on this building is compared . The impact on the performance of different types of construction is assessed for the night cooling ventilation strategy. The results show that night cooling is superior to daytime ventilative cooling in the three cities. Night cooling can successfully replace air conditioning systems for a significant part of the cooling season in Beijing and Tokyo. For Shanghai, neither of the two passive ventilation systems can be considered successful. In both Beijing and Tokyo the application of night cooling may cause condensation in partitions. The use of heavyweight partitions does not show a noticeable improvement over normal construction (using 10cm concrete partitions) . On the other hand, the lightweight case shows a noticeable degradation in system performance. Therefore, the normal structural system is the best option. The use of carpet has a very negative impact on night cooling performance, and is therefore not advised. by Guilherme Carrilho da Graça. S.M. 2011-11-01T19:44:27Z 2011-11-01T19:44:27Z 1999 1999 Thesis http://hdl.handle.net/1721.1/66785 43626775 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 166 p. application/pdf Massachusetts Institute of Technology |
spellingShingle | Architecture. Graça, Guilherme Carrilho da, 1972- Ventilative cooling |
title | Ventilative cooling |
title_full | Ventilative cooling |
title_fullStr | Ventilative cooling |
title_full_unstemmed | Ventilative cooling |
title_short | Ventilative cooling |
title_sort | ventilative cooling |
topic | Architecture. |
url | http://hdl.handle.net/1721.1/66785 |
work_keys_str_mv | AT gracaguilhermecarrilhoda1972 ventilativecooling |