_version_ 1826203707728986112
author Xing, Hai-Yun Helen, 1976-
author2 Leon K. Glicksman and Leslie K. Norford.Three criteria are put forward to evaluate the performances of a desiccant dehumidification system for building applications: adsorption rate, average outlet air parameters and energy consumption. A systematic way is proposed to size a desiccant unit and optimize its operations by using the model developed before. In a case study a desiccant unit is designed for a two-people room in Shanghai for ventilation purposes and the unit's operations are optimized. The design results show that desiccant dehumidification can be used in building applications, provided appropriate operation parameters are adopted. The yearly operations of a desiccant dehumidification system are proposed.
author_facet Leon K. Glicksman and Leslie K. Norford.Three criteria are put forward to evaluate the performances of a desiccant dehumidification system for building applications: adsorption rate, average outlet air parameters and energy consumption. A systematic way is proposed to size a desiccant unit and optimize its operations by using the model developed before. In a case study a desiccant unit is designed for a two-people room in Shanghai for ventilation purposes and the unit's operations are optimized. The design results show that desiccant dehumidification can be used in building applications, provided appropriate operation parameters are adopted. The yearly operations of a desiccant dehumidification system are proposed.
Xing, Hai-Yun Helen, 1976-
author_sort Xing, Hai-Yun Helen, 1976-
collection MIT
description Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Architecture, 2000.
first_indexed 2024-09-23T12:41:48Z
format Thesis
id mit-1721.1/70736
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T12:41:48Z
publishDate 2012
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/707362019-04-11T12:48:40Z Desiccant dehumidification analysis Xing, Hai-Yun Helen, 1976- Leon K. Glicksman and Leslie K. Norford.Three criteria are put forward to evaluate the performances of a desiccant dehumidification system for building applications: adsorption rate, average outlet air parameters and energy consumption. A systematic way is proposed to size a desiccant unit and optimize its operations by using the model developed before. In a case study a desiccant unit is designed for a two-people room in Shanghai for ventilation purposes and the unit's operations are optimized. The design results show that desiccant dehumidification can be used in building applications, provided appropriate operation parameters are adopted. The yearly operations of a desiccant dehumidification system are proposed. Massachusetts Institute of Technology. Dept. of Architecture. Massachusetts Institute of Technology. Dept. of Architecture. Architecture. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Architecture, 2000. Includes bibliographical references (p. 115-116). Desiccant dehumidification has been given increasing interest in the air conditioning industry. Compared with conventional vapor compression air conditioning systems, desiccant dehumidification saves energy by separating humidity control from temperature control and also improves the indoor air quality as a good filter. This research explores the potential of applying desiccant dehumidification systems in buildings with less energy consumption. As the first step, the adsorption mechanism is explored and desiccant material properties are obtained based on a literature review. The heat and mass transfer in the desiccant - moist air system is well understood and modeled using both pseudo-gas-side controlled (PGC) transfer coefficients and semi-infinite transfer coefficients. Compared with experimental data, the model well predicts single processes while the prediction for cyclic processes is acceptable for practical applications. This model provides a useful tool for two purposes: analysis of desiccant unit 's performances and optimization of the design and operations of a unit. Based on the semi-infinite body theory, the semi-infinite model provides a way to simplify the solid-side diffusion resistance. A temperature control strategy is proposed to improve the mass transfer efficiency. A design in which the desiccant temperature is controlled in sections is tested using the model developed before. Simulations show that temperature control enhances mass transfer. Using the model, parametric analysis is conducted on a temperature-control led packed-bed desiccant unit. The effects on dehumidification performances of processing air mass flow rate, regeneration temperature and cycle time are studied. Parametric analysis gains insight into the correlations and interactions between different operation parameters. by Hai-Yun Helen Xing. S.M. 2012-05-15T21:07:45Z 2012-05-15T21:07:45Z 2000 2000 Thesis http://hdl.handle.net/1721.1/70736 48455670 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 139 p. application/pdf Massachusetts Institute of Technology
spellingShingle Architecture.
Xing, Hai-Yun Helen, 1976-
Desiccant dehumidification analysis
title Desiccant dehumidification analysis
title_full Desiccant dehumidification analysis
title_fullStr Desiccant dehumidification analysis
title_full_unstemmed Desiccant dehumidification analysis
title_short Desiccant dehumidification analysis
title_sort desiccant dehumidification analysis
topic Architecture.
url http://hdl.handle.net/1721.1/70736
work_keys_str_mv AT xinghaiyunhelen1976 desiccantdehumidificationanalysis