Optimal operation and design of solar-thermal energy storage systems

Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.

Bibliographic Details
Main Author: Lizarraga-García, Enrique
Other Authors: Alexander Mitsos.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2012
Subjects:
Online Access:http://hdl.handle.net/1721.1/74925
_version_ 1826210908446130176
author Lizarraga-García, Enrique
author2 Alexander Mitsos.
author_facet Alexander Mitsos.
Lizarraga-García, Enrique
author_sort Lizarraga-García, Enrique
collection MIT
description Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.
first_indexed 2024-09-23T14:57:41Z
format Thesis
id mit-1721.1/74925
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T14:57:41Z
publishDate 2012
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/749252019-04-12T15:26:05Z Optimal operation and design of solar-thermal energy storage systems Lizarraga-García, Enrique Alexander Mitsos. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012. Cataloged from PDF version of thesis. Includes bibliographical references (p. 99-105). The present thesis focuses on the optimal operation and design of solar-thermal energy storage systems. First, optimization of time-variable operation to maximize revenue through selling and purchasing electricity to/from the grid is presented for a thermal energy storage system. Time-variable electricity prices and electricity buy-back from the grid to re-charge the energy storage is considered. The concentrated solar power on demand (CSPonD) concept, in which a salt pond receives solar energy, stores thermal energy, and delivers thermal energy to the power cycle is considered. Electric heaters are added to the CSPonD concept, allowing for periods of electricity buy-back from the grid to re-charge the energy storage. System-level models are developed and optimization of the design and operation is performed with local solvers. Three main case studies are considered: the first case study investigates the optimization of time-variable operation without electrical heating under time-invariant electricity price; the second case study optimizes the operation under time-variant electricity price without electric heaters; the third case study optimizes the operation under time-variant electricity price allowing charging of the pond using the grid electricity. The first case study reflects the time-invariant tariff model, whereas the second and third case studies consider a time-of-use feed-in-tariff. Two hourly price profiles are considered in order to assess the influence of it on the optimal design and operation of the thermal energy storage. The first electricity profile consists of a price profile that fluctuates moderately, and the second price profile fluctuates highly, including negative prices. The results show significant increase in the revenue when adding electric heaters. Under the moderately fluctuating electricity price, the use of heaters increases the revenue significantly, compared to the same case with no electric heaters considered. Under the highly fluctuating electricity price, the use of heaters more than doubles the revenue, compared to the same case with no electric heaters considered. Also, the performance analysis of a regenerative thermal energy storage system with enhancement heat transfer structures is presented. In a regenerative thermal storage system, thermal energy is transferred from a hot heat transfer fluid to the storage unit core elements during charge, and from the core elements to the cold heat transfer fluid during discharge. Herein, concrete as the solid storage material, nitrate solar salt as the heat transfer fluid, and aluminum plates as the heat transfer structures is considered. The discharge process from uniform initial temperature is studied with different configurations (pure concrete and concrete enhanced by transfer structures), operation strategies (laminar versus turbulent flow regimes), and dimensions. Results show a significant decrease in the cost of the thermal energy storage system when heat transfer structures are added, as well as a better performance in terms of discharge efficiency and discharge time period. The amount of solar salt needed for this configuration is approximately one fourth that required for a nitrate two-tank system operating with the same temperature difference. by Enrique Lizarraga-García. S.M. 2012-11-19T19:18:58Z 2012-11-19T19:18:58Z 2012 2012 Thesis http://hdl.handle.net/1721.1/74925 815767453 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 105 p. application/pdf Massachusetts Institute of Technology
spellingShingle Mechanical Engineering.
Lizarraga-García, Enrique
Optimal operation and design of solar-thermal energy storage systems
title Optimal operation and design of solar-thermal energy storage systems
title_full Optimal operation and design of solar-thermal energy storage systems
title_fullStr Optimal operation and design of solar-thermal energy storage systems
title_full_unstemmed Optimal operation and design of solar-thermal energy storage systems
title_short Optimal operation and design of solar-thermal energy storage systems
title_sort optimal operation and design of solar thermal energy storage systems
topic Mechanical Engineering.
url http://hdl.handle.net/1721.1/74925
work_keys_str_mv AT lizarragagarciaenrique optimaloperationanddesignofsolarthermalenergystoragesystems