Design optimization of oxygenated fluid pump
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.
Main Author: | |
---|---|
Other Authors: | |
Format: | Thesis |
Language: | eng |
Published: |
Massachusetts Institute of Technology
2012
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/75673 |
_version_ | 1811092211730743296 |
---|---|
author | Piazzarolo, Bruno Aiala |
author2 | Alexander H. Slocum. |
author_facet | Alexander H. Slocum. Piazzarolo, Bruno Aiala |
author_sort | Piazzarolo, Bruno Aiala |
collection | MIT |
description | Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012. |
first_indexed | 2024-09-23T15:14:43Z |
format | Thesis |
id | mit-1721.1/75673 |
institution | Massachusetts Institute of Technology |
language | eng |
last_indexed | 2024-09-23T15:14:43Z |
publishDate | 2012 |
publisher | Massachusetts Institute of Technology |
record_format | dspace |
spelling | mit-1721.1/756732019-04-12T09:29:42Z Design optimization of oxygenated fluid pump Piazzarolo, Bruno Aiala Alexander H. Slocum. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012. Cataloged from PDF version of thesis. Includes bibliographical references (p. 66). In medical emergencies, an oxygen-starved brain quickly suffers irreparable damage. In many cases, patients who stop breathing can be resuscitated but suffer from brain damage. Dr. John Kheir from Boston Children's Hospital created a compressible fluid that can re-oxygenate blood quickly in patients with asphyxia and cardiac arrest. Because the fluid is compressible, the set infusion rate on an ordinary pump does not necessarily indicate what is delivered. In addition, the fluid is provided at a 90% gas by volume concentration and is extremely viscous. The goal of this project is to create a pump to deliver a specified volumetric flow rate of the oxygenated fluid created by the doctor. The pump design uses a bellows with force feedback calibration to pump 1 liter of fluid over 5 minutes and mix the concentrated 90% form with saline without degradation to form a 70% concentrated form with the viscosity similar to that of blood. My part in the project was to create the control system that would drive the pump using a force feedback and to optimize the design of the pump The oxygenated fluid pump built can successfully store and dispense one liter of fluid, mix the concentrated form of the oxygenated fluid with saline, maintain sterility, and preserve the fluid's properties, all in a cost appropriate manner. It is a modular design that can easily be modified to improve its performance. Further testing is required to tune the control system and ensure that the flow rate is accurate to ±10%. The pump is mostly being used as a research tool in order to run tests that will help characterize the fluid and later can be used for small and large animal testing. by Bruno Aiala Piazzarolo. S.B. 2012-12-13T18:51:06Z 2012-12-13T18:51:06Z 2012 2012 Thesis http://hdl.handle.net/1721.1/75673 819968855 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 81 p. application/pdf Massachusetts Institute of Technology |
spellingShingle | Mechanical Engineering. Piazzarolo, Bruno Aiala Design optimization of oxygenated fluid pump |
title | Design optimization of oxygenated fluid pump |
title_full | Design optimization of oxygenated fluid pump |
title_fullStr | Design optimization of oxygenated fluid pump |
title_full_unstemmed | Design optimization of oxygenated fluid pump |
title_short | Design optimization of oxygenated fluid pump |
title_sort | design optimization of oxygenated fluid pump |
topic | Mechanical Engineering. |
url | http://hdl.handle.net/1721.1/75673 |
work_keys_str_mv | AT piazzarolobrunoaiala designoptimizationofoxygenatedfluidpump |