Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure

Thesis (S.M.)--Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, 2012.

Bibliographic Details
Main Author: Hill, David Allen, Ph. D. Massachusetts Institute of Technology
Other Authors: Hugh Herr.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2013
Subjects:
Online Access:http://hdl.handle.net/1721.1/76517
_version_ 1811081237084766208
author Hill, David Allen, Ph. D. Massachusetts Institute of Technology
author2 Hugh Herr.
author_facet Hugh Herr.
Hill, David Allen, Ph. D. Massachusetts Institute of Technology
author_sort Hill, David Allen, Ph. D. Massachusetts Institute of Technology
collection MIT
description Thesis (S.M.)--Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, 2012.
first_indexed 2024-09-23T11:43:37Z
format Thesis
id mit-1721.1/76517
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T11:43:37Z
publishDate 2013
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/765172019-04-12T21:33:22Z Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure Hill, David Allen, Ph. D. Massachusetts Institute of Technology Hugh Herr. Massachusetts Institute of Technology. Dept. of Architecture. Program in Media Arts and Sciences. Massachusetts Institute of Technology. Dept. of Architecture. Program in Media Arts and Sciences. Architecture. Program in Media Arts and Sciences. Thesis (S.M.)--Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, 2012. Cataloged from PDF version of thesis. Includes bibliographical references (p. 83-86). Lower-extremity amputees face potentially serious post-operative complications, including increased risk of further amputations, excessive stress on both limbs, and discomfort at the stump/socket interface. State of the art; passive prostheses have improved many negative consequences associated with lower-limb loss, but we believe the limit of uninformed elastic prostheses has been reached. Further strides require a more biomimetic approach. Through integration of "smart" technology (sensors and actuators), a new phase of bionic lower-limb prostheses is upon us, which enables prosthetic devices to more closely mimic biological behavior by generating human-like responses and power outputs. The closer we come to natural biology, gait abnormalities in amputees will decline. This project compares the first bionic ankle prosthesis to commonly used passive prostheses to determine how more biomimetic adaptability and work generation in the prosthetic joint affects discomfort and joint stress. We have put forth several metrics to describe discomfort (elements of shock absorption, pressure distribution, etc.) and will conduct level-ground walking tests with three unilateral amputee subjects using both passive and power devices. We hope to make a case for the pursuit of more biomimetic designs for rehabilitative devices, by showing a positive effect on "comfort" and a restoration of normal gait dynamics when using a bionic ankle prosthesis. by David Allen Hill. S.M. 2013-01-23T19:47:47Z 2013-01-23T19:47:47Z 2012 2012 Thesis http://hdl.handle.net/1721.1/76517 823865032 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 86 p. application/pdf Massachusetts Institute of Technology
spellingShingle Architecture. Program in Media Arts and Sciences.
Hill, David Allen, Ph. D. Massachusetts Institute of Technology
Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure
title Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure
title_full Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure
title_fullStr Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure
title_full_unstemmed Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure
title_short Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure
title_sort effects of a powered ankle prosthesis on shock absorption and residual limb socket interface pressure
topic Architecture. Program in Media Arts and Sciences.
url http://hdl.handle.net/1721.1/76517
work_keys_str_mv AT hilldavidallenphdmassachusettsinstituteoftechnology effectsofapoweredankleprosthesisonshockabsorptionandresiduallimbsocketinterfacepressure